Researcher profile

David Fernandez Rivas

David Fernandez Rivas contributes to research discovery and scholarly infrastructure.

ResearcherAffiliation not importedOpen to collaborate

Trust snapshot

Quick read

Trust 21 - EmergingVerification L1Unclaimed author
8works
0followers
6topics
4close collaborators

Actions

Decide how to stay connected

Follow researcher0

Identity and collaboration

How to connect with this researcher

Claiming links this public author record to a researcher profile and unlocks direct collaboration workflows.

Log in to claim

Direct collaboration

Open a focused conversation when the fit is right

Claim this author entity first to unlock direct invitations.

Research graph

See the researcher in context

Open full explorer

Inspect adjacent work, topics, institutions and collaborators without jumping out to a separate graph page.

Building this graph slice

BZPEER is loading the nearby papers, people, topics and institutions for this page.

Published work

8 published item(s)

preprint2023arXiv

Laser beam properties and microfluidic confinement control thermocavitation

Thermocavitation, the creation of a vapor bubble by heating a liquid with a continuous-wave laser, has been studied for a wide range of applications. Examples include the development of an actuator for needle-free jet injectors, as the pumping mechanism in microfluidic channels and crystallization or nanoparticle synthesis. Optimal use in these applications require control over the dynamics of the laser-generated bubble through the laser power and beam radius. In contrast to pulsed lasers, for continuous-wave lasers the influence of the laser beam radius on the bubble characteristics is not fully understood. Here, we present a novel way to control the size of the beam from an optical fiber by changing the distance from the glass-liquid interface. We show that the increase in beam size results in a longer nucleation time. Numerical simulations of the experiment show that the maximum temperature at the moment of nucleation is 237$\pm$5°C and independent of laser parameters. Due to delayed nucleation for larger beam sizes, more energy is absorbed by the liquid at the nucleation instant. Consequently, a larger beam size results in a faster growing bubble, producing the same effect as reducing the laser power. We conclude that the total bubble energy only depends on the amount of absorbed optical energy and it is independent of the beam radius and laser power for any amount of absorbed energy. This effect contrasts with pulsed lasers, where an increase in beam radius results in a reduction of bubble energy. Our results are of relevance for the use of continuous-wave laser-actuated cavitation in needle-free jet injectors as well as other applications of thermocavitation in microfluidic confinement.

preprint2022arXiv

Cavity dynamics after the injection of a microfluidic jet in capillary bridges

The impact of solid and liquid objects (projectiles) onto liquids and soft solids (targets) generally results on the creation and expansion of an air cavity inside the impacted objects. The dynamics of cavity expansion and collapse depends on the projectile inertia as well as on the target properties. In this paper we study the impact of microfluidic jets generated by thermocavitation processes on a capillary bridge between two parallel planar walls. Different capillary bridge types were studied, Newtonian liquids, viscoelastic liquids and agarose gels. Thus, we compare the cavity formation and collapse between a wide range of material properties. Moreover, we model the critical impact velocity for a jet to traverse a capillary bridge type. Our results show that agarose gels with a storage modulus lower that 176 Pa can be modelled as a liquid for this transition. However, the predicted transition deviates for agarose gels with higher storage modulus. Additionally, we show different types of cavity collapse, depending on the Weber number and the capillary bridge properties. We conclude that the type of collapse determines the number and size of entrained bubbles. Furthermore, we study the effects of wettability on the adhesion forces and contact line dissipation. We conclude that upon cavity collapse, for hydrophobic walls a Worthington jet is energetically favourable. In contrast, for hydrophilic walls, the contact line dissipation is in the same order of magnitude of the energy of the impacted jet, suppressing the Worthington jet formation. Our results provide strategies for preventing bubble entrapment and give an estimation of the cavity dynamics for needle-free injection applications and additive manufacturing among other applications.

preprint2022arXiv

Microfluidic jet impact: spreading, splashing, soft substrate deformation and injection

Injecting with needles causes fear, pain and contamination risks. Billions of injections every year also cause environmental burden in terms of material consumption and waste. Controlled microfluidic-jet injection systems offer a needle-free alternative. However, understanding the relation between jet parameters and resulting injection depth are needed to enable targeting specific skin layers, and enhance the pharmacokinetics of various therapeutic compounds. The complexity of skin, its opacity and non-linear mechanical properties, pose a technological challenge. Hence the use of surrogates is instrumental to understand how to inject without needles. In particular, reducing undesired splashing upon jet impact and liquid squeeze-out after injection are needed to minimize infection risks and ensure accurate dosage. Therefore, in this paper we explore how microfluidic jet characteristics influence the impact outcome on a range of materials as skin surrogate. Jets with velocities between 7 - 77 m/s and diameters 35 - 130 $μ$m were directed at substrates with shear moduli between 0.2 kPa and 26 GPa. We found seven different regimes depending on jet inertia and substrate shear modulus. Furthermore, three distinct transition regions were identified as the thresholds between regimes: i) spreading/splashing threshold, ii) dimple formation threshold, and iii) plastic/elastic deformation threshold. These thresholds allow predicting the required jet velocity and diameter to inject substrates with known shear modulus. We found that jet velocity is a better predictor for the injection depth compared to the Weber number, as the jet diameter does not influence the injection depth. Our findings are relevant for advancing needle-free injection research, because the shear modulus of skin depends on multiple factors, such as ethnicity, body part and environmental conditions.

preprint2020arXiv

Microuidics control the ballistic energy of thermocavitation liquid jets for needle-free injections

Illuminating a water solution with a focused continuous wave laser produces a strong local heating of the liquid that leads to the nucleation of bubbles, also known as thermocavitation. During the growth of the bubble, the surrounding liquid is expelled from the constraining microfluidic channel through a nozzle, creating a jet. The characteristics of the resulting liquid jet was imaged using ultra-fast imaging techniques. Here, we provide a phenomenological description of the jet shapes and velocities, and compare them with a Boundary Integral numerical model. We define the parameter regime, varying jet speed, taper geometry and liquid volume, for optimal printing, injection and spray applications. These results are important for the design of energy-efficient needle-free jet injectors based on microfluidic thermocavitation.

preprint2013arXiv

Interacting bubble clouds and their sonochemical production

Acoustically driven air pockets trapped in artificial crevices on a sur- face can emit bubbles which organize in (interacting) bubble clusters. With increasing driving power Fernandez Rivas et al. [Angew. Chem. Int. Ed., 2010] observed three different behaviors: clusters close to the very pits out of which they had been created, clusters pointing toward each other, and merging clusters. The latter behavior is highly undesired for technological purposes as it is associated with a reduction of the radical production and an enhancement of the erosion of the reactor walls. The dependence on the control parameters such as the distance of the pits and the conditions for cluster-merging are examined. The underlying mechanism, governed by the secondary Bjerknes forces, turns out to be strongly influenced by the nonlinearity of the bubble oscillations and not directly by the number of nucleated bubbles. The Bjerknes forces are found to dampen the bubble oscillations, thus reducing the radical production. Therefore, the increased number of bubbles at high power could be the key to understand the experimental observation that, after a certain power threshold, any further increase of the driving does not improve the sonochemical efficiency.

preprint2012arXiv

Efficient Sonochemistry through Microbubbles Generated with Micromachined Surfaces

Sonochemical reactors are used in water treatment, the synthesis of fine chemicals, pharmaceutics and others. The low efficiency of sonoreactors have prevented its massive usage at industrial scales. Controlling the appearance of bubbles in place and time is the most limiting factor. A novel type of sonochemical reactor was designed making use of micro-fabrication techniques to control the nucleation sites of micro-bubbles. The efficiency was increased first by locating the nucleation sites in the most active region of a micro-chamber; additionally the desired chemical effect was significantly higher at the same powers than when not controlled. Silicon substrates were micromachined with "artificial nucleation sites" or pits, and placed at the bottom of the micro-chamber. The pits entrap gas which, upon ultrasonic excitation, sheds off a stream of microbubbles. The gas content of the pits is not depleted but is replenished by diffusion and the emission of microbubbles can continue for hours.

preprint2012arXiv

Sonoluminescence and sonochemiluminescence from a microreactor

Micromachined pits on a substrate can be used to nucleate and stabilize microbubbles in a liquid exposed to an ultrasonic field. Under suitable conditions, the collapse of these bubbles can result in light emission (sonoluminescence, SL). Hydroxyl radicals (OH*) generated during bubble collapse can react with luminol to produce light (sonochemiluminescence, SCL). SL and SCL intensities were recorded for several regimes related to the pressure amplitude (low and high acoustic power levels) at a given ultrasonic frequency (200 kHz) for pure water, and aqueous luminol and propanol solutions. Various arrangements of pits were studied, with the number of pits ranging from no pits (comparable to a classic ultrasound reactor), to three-pits. Where there was more than one pit present, in the high pressure regime the ejected microbubbles combined into linear (two-pits) or triangular (three-pits) bubble clouds (streamers). In all situations where a pit was present on the substrate, the SL was intensified and increased with the number of pits at both low and high power levels. For imaging SL emitting regions, Argon (Ar) saturated water was used under similar conditions. SL emission from aqueous propanol solution (50 mM) provided evidence of transient bubble cavitation. Solutions containing 0.1 mM luminol were also used to demonstrate the radical production by attaining the SCL emission regions.

preprint2012arXiv

Taming Acoustic Cavitation

In this fluid dynamics video we show acoustic cavitation occurring from pits etched on a silicon surface. By immersing the surface in a liquid, gas pockets are entrapped in the pits which upon ultrasonic insonation, are observed to shed cavitation bubbles. Modulating the driving pressure it is possible to induce different behaviours based on the force balance that determines the interaction among bubbles and the silicon surface. This system can be used for several applications like sonochemical water treatment, cleaning of surfaces with deposited materials such as biofilms.