Researcher profile

David Berge

David Berge contributes to research discovery and scholarly infrastructure.

ResearcherAffiliation not importedOpen to collaborate

Trust snapshot

Quick read

Trust 15 - UnverifiedVerification L1Unclaimed author
3works
0followers
2topics
4close collaborators

Actions

Decide how to stay connected

Follow researcher0

Identity and collaboration

How to connect with this researcher

Claiming links this public author record to a researcher profile and unlocks direct collaboration workflows.

Log in to claim

Direct collaboration

Open a focused conversation when the fit is right

Claim this author entity first to unlock direct invitations.

Research graph

See the researcher in context

Open full explorer

Inspect adjacent work, topics, institutions and collaborators without jumping out to a separate graph page.

Building this graph slice

BZPEER is loading the nearby papers, people, topics and institutions for this page.

Published work

3 published item(s)

preprint2022arXiv

Characterization of a CdZnTe detector for a low-power CubeSat application

We report spectral and imaging performance of a pixelated CdZnTe detector custom designed for the \emph{MeVCube} project: a small Compton telescope on a CubeSat platform. \emph{MeVCube} is expected to cover the energy range between $200\;\mathrm{keV}$ and $4\;\mathrm{MeV}$, with performance comparable to the last generation of larger satellites. In order to achieve this goal, an energy resolution of few percent in full width at half maximum (FWHM) and a $3$-D spatial resolution of few millimeters for the individual detectors are needed. The severe power constraints present in small satellites require very low power read-out electronics for the detector. Our read-out is based on the VATA450.3 ASIC developed by \emph{Ideas}, with a power consumption of only $0.25\;\mathrm{mW/channel}$, which exhibits good performance in terms of dynamic range, noise and linearity. A $2.0\;\mathrm{cm} \times 2.0\;\mathrm{cm} \times 1.5\;\mathrm{cm}$ CdZnTe detector, with a custom $8 \times 8$ pixel anode structure read-out by a VATA450.3 ASIC, has been tested. A preliminary read-out system for the cathode, based on a discrete \emph{Amptek} A250F charge sensitive pre-amplifier and a DRS4 ASIC, has been implemented. An energy resolution around $3\%$ FWHM has been measured at a gamma energy of $662\;\mathrm{keV}$; at $200\;\mathrm{keV}$ the average energy resolution is $6.5\%$, decreasing to $\lesssim 2\%$ at energies above $1\;\mathrm{MeV}$. A $3$-D spatial resolution of $\approx 2\,\mathrm{mm}$ is achieved.

preprint2022arXiv

Introducing the MeVCube concept: a CubeSat for MeV observations

Despite the impressive progress achieved both by X-ray and gamma-ray observatories in the last few decades, the energy range between $\sim200\;\mathrm{keV}$ and $\sim50\;\mathrm{MeV}$ remains poorly explored. COMPTEL, on-board the Compton Gamma-Ray Observatory (CGRO, $1991$-$2000$), opened the MeV gamma-ray band as a new window to astronomy, performing the first all-sky survey in the energy range from $0.75$ to $30\;\mathrm{MeV}$. More than $20$ years after the de-orbit of CGRO, no successor mission is yet operating. Over the past years many concepts have been proposed, for new observatories exploring different configurations and imaging techniques; a selection of the most recent ones includes AMEGO, ETCC, GECCO and COSI. We propose here a novel concept for a Compton telescope based on the CubeSat standard, named MeVCube, with the advantages of small cost and relatively short development time. The scientific payload is based on two layers of pixelated Cadmium-Zinc-Telluride (CdZnTe) detectors, coupled with low-power read-out electronics (ASIC, VATA450.3). The performance of the read-out electronics and CdZnTe custom designed detectors have been measured extensively at DESY. The performance of the telescope is accessed through simulations: despite a small effective area limited to a few $\mathrm{cm}^{2}$, MeVCube can reach an angular resolution of $1.5^{\circ}$ and a sensitivity comparable to the one achieved by the last generation of large-scale satellites like COMPTEL and INTEGRAL. Combined with a large field-of-view and a moderate cost, MeVCube can be a powerful instrument for transient observations and searches of electromagnetic counterparts of gravitational wave events.

preprint2020arXiv

A NECTAr-based upgrade for the Cherenkov cameras of the H.E.S.S. 12-meter telescopes

The High Energy Stereoscopic System (H.E.S.S.) is one of the three arrays of imaging atmospheric Cherenkov telescopes (IACTs) currently in operation. It is composed of four 12-meter telescopes and a 28-meter one, and is sensitive to gamma rays in the energy range ~30 GeV - 100 TeV. The cameras of the 12-m telescopes recently underwent a substantial upgrade, with the goal of improving their performance and robustness. The upgrade involved replacing all camera components except for the photomultiplier tubes (PMTs). This meant developing new hardware for the trigger, readout, power, cooling and mechanical systems, and new software for camera control and data acquisition. Several novel technologies were employed in the cameras: the readout is built around the new NECTAr digitizer chip, developed for the next generation of IACTs; the camera electronics is fully controlled and read out via Ethernet using a combination of FPGA and embedded ARM computers; the software uses modern libraries such as Apache Thrift, ZMQ and Protocol buffers. This work describes in detail the design and the performance of the upgraded cameras.