Source author record

Daisuke Tatsumi

Daisuke Tatsumi appears in the imported research catalog. Authorship, coauthor and topic links are available while profile ownership is still unclaimed.

ResearcherUnclaimed source record

Catalog footprint

What is connected

5works
5topics
4close collaborators

Actions

Connect this record

Log in to claim

Research graph

See the researcher in context

Open full explorer

Inspect adjacent papers, topics, institutions and collaborators without losing the researcher page.

Building this map preview

BZPEER is loading the nearby papers, people, topics and institutions for this page.

Published work

5 published item(s)

preprint2020arXiv

Estimation of losses in a 300 m filter cavity and quantum noise reduction in the KAGRA gravitational-wave detector

The sensitivity of the gravitational-wave detector KAGRA, presently under construction, will be limited by quantum noise in a large fraction of its spectrum. The most promising technique to increase the detector sensitivity is the injection of squeezed states of light, where the squeezing angle is dynamically rotated by a Fabry-Pérot filter cavity. One of the main issues in the filter cavity design and realization is the optical losses due to the mirror surface imperfections. In this work we present a study of the specifications for the mirrors to be used in a 300 m filter cavity for the KAGRA detector. A prototype of the cavity will be constructed at the National Astronomical Observatory of Japan, inside the infrastructure of the former TAMA interferometer. We also discuss the potential improvement of the KAGRA sensitivity, based on a model of various realistic sources of losses and their influence on the squeezing amplitude.

preprint2013arXiv

Interferometer design of the KAGRA gravitational wave detector

KAGRA is a cryogenic interferometric gravitational wave detector being constructed at the underground site of Kamioka mine in Gifu prefecture, Japan. We performed an optimization of the interferomter design, to achieve the best sensitivity and a stable operation, with boundary conditions of classical noises and under various practical constraints, such as the size of the tunnel or the mirror cooling capacity. Length and alignment sensing schemes for the robust control of the interferometer are developed. In this paper, we describe the detailed design of the KAGRA interferometer as well as the reasoning behind design choices.

preprint2012arXiv

Reduction of thermal fluctuations in a cryogenic laser interferometric gravitational wave detector

The thermal fluctuation of mirror surfaces is the fundamental limitation for interferometric gravitational wave (GW) detectors. Here, we experimentally demonstrate for the first time a reduction in a mirror's thermal fluctuation in a GW detector with sapphire mirrors from the Cryogenic Laser Interferometer Observatory at 17\,K and 18\,K. The detector sensitivity, which was limited by the mirror's thermal fluctuation at room temperature, was improved in the frequency range of 90\,Hz to 240\,Hz by cooling the mirrors. The improved sensitivity reached a maximum of $2.2 \times 10^{-19}\,\textrm{m}/\sqrt{\textrm{Hz}}$ at 165\,Hz.

preprint2011arXiv

Prospects for true calorimetry on Kerr black holes in core-collapse supernovae and mergers

Observational evidence for black hole spin down has been found in the normalized light curves of long GRBs in the BATSE catalogue. Over the duration $T_{90}$ of the burst, matter swept up by the central black hole is susceptible to non-axisymmetries producing gravitational radiation with a negative chirp. A time sliced matched filtering method is introduced to capture phase-coherence on intermediate timescales, $τ$, here tested by injection of templates into experimental strain noise, $h_n(t)$. For TAMA 300, $h_n(f)\simeq 10^{-21}$ Hz$^{-\frac{1}{2}}$ at $f=1$ kHz gives a sensitivity distance for a reasonably accurate extraction of the trajectory in the time frequency domain of about $D\simeq 0.07-0.10$ Mpc for spin fown of black holes of mass $M=10-12M_\odot$ with $τ=1$ s. Extrapolation to advanced detectors implies $D\simeq 35-50$ Mpc for $h_n(f)\simeq 2\times 10^{-24}$ Hz$^{-\frac{1}{2}}$ around 1 kHz, which will open a new window to rigorous calorimetry on Kerr black holes.

preprint2010arXiv

Thermal-noise-limited underground interferometer CLIO

We report on the current status of CLIO (Cryogenic Laser Interferometer Observatory), which is a prototype interferometer for LCGT (Large Scale Cryogenic Gravitational-Wave Telescope). LCGT is a Japanese next-generation interferometric gravitational wave detector featuring the use of cryogenic mirrors and a quiet underground site. The main purpose of CLIO is to demonstrate a reduction of the mirror thermal noise by cooling the sapphire mirrors. CLIO is located in an underground site of the Kamioka mine, 1000 m deep from the mountain top, to verify its advantages. After a few years of commissioning work, we have achieved a thermal-noise-limited sensitivity at room temperature. One of the main results of noise hunting was the elimination of thermal noise caused by a conductive coil-holder coupled with a pendulum through magnets.