Source author record

D Nicolodi

D Nicolodi appears in the imported research catalog. Authorship, coauthor and topic links are available while profile ownership is still unclaimed.

ResearcherUnclaimed source record

Catalog footprint

What is connected

3works
7topics
4close collaborators

Actions

Connect this record

Log in to claim

Research graph

See the researcher in context

Open full explorer

Inspect adjacent papers, topics, institutions and collaborators without losing the researcher page.

Building this map preview

BZPEER is loading the nearby papers, people, topics and institutions for this page.

Published work

3 published item(s)

preprint2016arXiv

Comparing a mercury optical lattice clock with microwave and optical frequency standards

In this paper we report the evaluation of an optical lattice clock based on neutral mercury down to a relative uncertainty of $1.7\times 10^{-16}$. Comparing this characterized frequency standard to a Cs atomic fountain we determine the absolute frequency of the $^1S_0 \rightarrow \phantom{}^3P_0$ transition of $^{199}$Hg as $ν_{\mathrm{Hg}} = 1 128\,575\,290\,808\,154.62\,$Hz $\pm\,0.19\,$Hz (statistical) $\pm\,0.38\,$Hz (systematic), limited solely by the realization of the SI second. Furthermore, by comparing the mercury optical lattice clock to a Rb atomic fountain, we determine for the first time to our knowledge the ratio between the $^{199}$Hg clock transition and the $^{87}$Rb ground state hyperfine transition. Finally we present a direct optical to optical measurement of the $^{199}$Hg/$^{87}$Sr frequency ratio. The obtained value of $ν_{\mathrm{Hg}}/ν_{\mathrm{Sr}}=2.629\,314\,209\,898\,909\,15$ with a fractional uncertainty of $1.8\times10^{-16}$ is in excellent agreement with the same measurement obtained by Yamanaka et al. (arXiv:1503.07941). This makes this frequency ratio one of the few physical quantities agreed upon by different laboratories to this level of uncertainty. Frequency ratio measurements of the kind of those reported in this paper have a strong impact for frequency metrology but also for fundamental physics as they can be used to monitor putative variations of fundamental constants.

preprint2013arXiv

State space modelling and data analysis exercises in LISA Pathfinder

LISA Pathfinder is a mission planned by the European Space Agency to test the key technologies that will allow the detection of gravitational waves in space. The instrument on-board, the LISA Technology package, will undergo an exhaustive campaign of calibrations and noise characterisation campaigns in order to fully describe the noise model. Data analysis plays an important role in the mission and for that reason the data analysis team has been developing a toolbox which contains all the functionalities required during operations. In this contribution we give an overview of recent activities, focusing on the improvements in the modelling of the instrument and in the data analysis campaigns performed both with real and simulated data.

preprint2011arXiv

From laboratory experiments to LISA Pathfinder: achieving LISA geodesic motion

This paper presents a quantitative assessment of the performance of the upcoming LISA Pathfinder geodesic explorer mission. The findings are based on the results of extensive ground testing and simulation campaigns using flight hardware and flight control and operations algorithms. The results show that, for the central experiment of measuring the stray differential acceleration between the LISA test masses, LISA Pathfinder will be able to verify the overall acceleration noise to within a factor two of the LISA requirement at 1 mHz and within a factor 6 at 0.1 mHz. We also discuss the key elements of the physical model of disturbances, coming from LISA Pathfinder and ground measurement, that will guarantee the LISA performance.