Researcher profile

D. Maire

D. Maire contributes to research discovery and scholarly infrastructure.

ResearcherAffiliation not importedOpen to collaborate

Trust snapshot

Quick read

Trust 21 - EmergingVerification L1Unclaimed author
7works
0followers
4topics
4close collaborators

Actions

Decide how to stay connected

Follow researcher0

Identity and collaboration

How to connect with this researcher

Claiming links this public author record to a researcher profile and unlocks direct collaboration workflows.

Log in to claim

Direct collaboration

Open a focused conversation when the fit is right

Claim this author entity first to unlock direct invitations.

Research graph

See the researcher in context

Open full explorer

Inspect adjacent work, topics, institutions and collaborators without jumping out to a separate graph page.

Building this graph slice

BZPEER is loading the nearby papers, people, topics and institutions for this page.

Published work

7 published item(s)

preprint2014arXiv

In situ measurement of the electron drift velocity for upcoming directional Dark Matter detectors

Three-dimensional track reconstruction is a key issue for directional Dark Matter detection and it requires a precise knowledge of the electron drift velocity. Magboltz simulations are known to give a good evaluation of this parameter. However, large TPC operated underground on long time scale may be characterized by an effective electron drift velocity that may differ from the value evaluated by simulation. In situ measurement of this key parameter is hence needed as it is a way to avoid bias in the 3D track reconstruction. We present a dedicated method for the measurement of the electron drift velocity with the MIMAC detector. It is tested on two gas mixtures: CF4 and CF4 + CHF3. The latter has been chosen for the MIMAC detector as we expect that adding CHF3 to pure CF4 will lower the electron drift velocity. This is a key point for directional Dark Matter as the track sampling along the drift field will be improved while keeping almost the same Fluorine content of the gas mixture. We show that the drift velocity at 50 mbar is reduced by a factor of about 5 when adding 30% of CHF3.

preprint2014arXiv

Measurement of a 127 keV Neutron Field with a micro-TPC Spectrometer

In order to measure the energy of neutron fields, with energy ranging from 8 keV to 1 MeV, a new primary standard is being developed at the IRSN (Institute for Radioprotection and Nuclear Safety). This project, micro-TPC (Micro Time Projection Chamber), carried out in collaboration with the LPSC (Laboratoire de Physique Subatomique et de Cosmologie), is based on the nuclear recoil detector principle. The instrument is presented with the associated method to measure the neutron energy. This article emphasizes the proton energy calibration procedure and energy measurements of a neutron field produced at 127 keV with the IRSN facility AMANDE.

preprint2014arXiv

Measurement of the electron drift velocity for directional dark matter detectors

Three-dimensional track reconstruction is a key issue for directional Dark Matter detection. It requires a precise knowledge of the electron drift velocity. Magboltz simulations are known to give a good evaluation of this parameter. However, large TPC operated underground on long time scale may be characterized by an effective electron drift velocity that may differ from the value evaluated by simulation. In situ measurement of this key parameter is hence a way to avoid bias in the 3D track reconstruction. We present a dedicated method for the measurement of the electron drift velocity with the MIMAC detector. It is tested on two gas mixtures : $\rm CF_4$ and $\rm CF_4+CHF_3$. We also show that adding $\rm CHF_3$ allows us to lower the electron drift velocity while keeping almost the same Fluorine content of the gas mixture.

preprint2013arXiv

Dark Matter directional detection with MIMAC

Directional detection is a promising direct Dark Matter (DM) search strategy. The angular distribution of the nuclear recoil tracks from WIMP events should present an anisotropy in galactic coordinates. This strategy requires both a measurement of the recoil energy with a threshold of about 5 keV and 3D recoil tracks down to few millimeters. The MIMAC project, based on a \textmu-TPC matrix, with $CF_4$ and $CHF_3$, is being developed. In June 2012, a bi-chamber prototype was installed at the LSM (Laboratoire Souterrain de Modane). A preliminary analysis of the first four months data taking allowed, for the first time, the observation of recoils from the $\mathrm{^{222}Rn}$ progeny.

preprint2013arXiv

Development of a microtpc detector as a standard instrument for low energy neutron field characterization

In order to measure energy and fluence of neutron fields, with energy ranging from 8 keV to 1 MeV, a new primary standard is being developed at the IRSN (Institute for Radioprotection and Nuclear Safety). This project, micro-TPC (Micro Time Projection Chamber), carried out in collaboration with the LPSC, is based on the nucleus recoil detector principle. The measurement strategy requires track reconstruction of recoiling nuclei down to a few keV, which can be achieved with a low pressure gaseous detector using a micro-pattern gaseous detector. A gas mixture, mainly isobutane, is used as a n-p converter to detect neutrons into the detection volume. Then electrons, coming from the ionization of the gas by the proton recoil, are collected by the pixelised anode (2D projection). A self-triggered electronics is able to perform the anode readout at a 50 MHz frequency in order to give the third dimension of the track. Then the scattering angle is deduced from this track using algorithms. The charge collection leads to the proton energy, taking into account the ionization quenching factor. This article emphasizes the neutron energy measurements of a monoenergetic neutron field produced at 127 keV. The measurements are compared to Monte Carlo simulations using realistic neutron fields and simulations of the detector response. The discrepancy between experiments and simulations is 5 keV mainly due to the calibration uncertainties of 10%.

preprint2013arXiv

MIMAC: A micro-tpc matrix for dark matter directional detection

The dark matter directional detection opens a new field in cosmology bringing the possibility to build a map of nuclear recoils that would be able to explore the galactic dark matter halo giving access to a particle characterization of such matter and the shape of the halo. The MIMAC (MIcro-tpc MAtrix of Chambers) collaboration has developed in the last years an original prototype detector based on the direct coupling of large pixelized micromegas with a devoted fast self-triggered electronics showing the feasibility of a new generation of directional detectors. The discovery potential of this search strategy is discussed and illustrated. In June 2012, the first bi-chamber prototype has been installed at Modane Underground Laboratory (LSM) and the first underground background events, the gain stability and calibration are shown.

preprint2013arXiv

MIMAC: MIcro-tpc MAtrix of Chambers for dark matter directional detection

Directional detection of non-baryonic Dark Matter is a promising search strategy for discriminating WIMP events from neutrons, the ultimate background for dark matter direct detection. This strategy requires both a precise measurement of the energy down to a few keV and 3D reconstruction of tracks down to a few mm. The MIMAC (MIcro-tpc MAtrix of Chambers) collaboration has developed in the last years an original prototype detector based on the direct coupling of large pixelized micromegas with a special developed fast self-triggered electronics showing the feasibility of a new generation of directional detectors. The first bi-chamber prototype has been installed at Modane, underground laboratory in June 2012. The first undergournd background events, the gain stability and calibration are shown. The first spectrum of nuclear recoils showing 3D tracks coming from the radon progeny is presented.