Source author record

O. Bourrion

O. Bourrion appears in the imported research catalog. Authorship, coauthor and topic links are available while profile ownership is still unclaimed.

ResearcherUnclaimed source record

Catalog footprint

What is connected

90works
9topics
4close collaborators

Actions

Connect this record

Log in to claim

Research graph

See the researcher in context

Open full explorer

Inspect adjacent papers, topics, institutions and collaborators without losing the researcher page.

Building this map preview

BZPEER is loading the nearby papers, people, topics and institutions for this page.

Published work

90 published item(s)

preprint2026arXiv

Resolved ISM properties and scaling relations in the barred galaxy NGC 3627: constraints from NIKA2 observations

We investigate the interplay between star formation, interstellar medium (ISM) components, and dust properties in NGC 3627 using new NIKA2 1.15 and 2 mm observations from the IMEGIN Large Program. Our goal is to analyze dust and radio emission, decompose contributions in the millimeter-centimeter regime, and explore ISM properties within the galaxy. We perform spectral energy distribution fitting, at both global and spatial scales, using the THEMIS dust model within the HerBIE code, applied to data from 3.4 $μ$m to 6 cm. We decompose emission into dust, free-free, and synchrotron components, and examine correlations with gas surface density and star formation activity. Additionally, we analyze the small dust grain fraction and its variation across the galaxy. We find $\sim$10% radio emission at 2 mm, peaking at 18% in the southern bar-end, which hosts the highest star formation activity. However, an isolated star-forming region beyond this bar-end is the most efficient, as indicated by its elevated dust production efficiency and effective yield, predicted by our simplistic dust evolution model. The 160 $μ$m emission shows the strongest correlation with molecular gas, while 1.15 mm better traces the dust mass surface density. Small grains, which make up $\sim$13% of dust mass (2 $\times$ 10$^{7}$ M$_{\odot}$), are depleted in intense radiation fields, with a notable deficit in the southern tidal tail. ISM properties and chemical evolution indicate that dynamical processes, such as bar-driven gas flows and tidal interactions, are crucial in shaping the galactic structure, influencing star formation efficiency, and dust distribution.

preprint2022arXiv

Massive merging cluster PSZ2G091 as seen by the NIKA2 camera

PSZ2 G091.83+26.11 is a galaxy cluster with M500 = 7.43 x 10^14 Msun at z = 0.822 1. This object exhibits a complex morphology with a clear bimodality observed in X-rays. However, it was detected and analysed in the Planck sample as a single, spherical cluster following a universal profile 2. This model can lead to miscalculations of thermodynamical quantities, like the pressure profile. As future multiwavelength cluster experiments will detect more and more objects at high redshifts, it is crucial to quantify this systematic effect. In this work, we use high-resolution observations of the NIKA2 camera3,4,5,6 to integrate the morphological characteristics of the cluster in our modelling. This is achieved by fitting a two-halo model to the SZ image and then by reconstruction of the resulting projected pressure profile. We then compare these results with the spherical assumption.

preprint2021arXiv

CONCERTO at APEX: Installation and first phase of on-sky commissioning

CONCERTO (CarbON CII line in post-rEionisation and ReionisaTiOn) is a large field-of-view (FoV) spectro-imager that has been installed on the Cassegrain Cabin of Atacama Pathfinder EXperiment (APEX) telescope in April 2021. CONCERTO hosts 2 focal planes and a total number of 4000 Kinetic Inductance Detectors (KID), with an instantaneous FoV of 18.6 arcminutes in the range of 130-310 GHz. The spectral resolution can be easily tuned down to 1 GHz depending on the scientific target. The scientific program of CONCERTO has many objectives, with two main programs focused on mapping the fluctuations of the [CII] line intensity in the reionisation and post-reionisation epoch (4.5<z<8.5), and on studying galaxy clusters via the thermal and kinetic Sunyaev-Zel'dovich (SZ) effect. CONCERTO will also measure the dust and molecular gas contents of local and intermediate-redshift galaxies, it will study the Galactic star-forming clouds and finally it will observe the CO intensity fluctuations arising from 0.3<z<2 galaxies. The design of the instrument, installation at APEX and current status of the commissioning phase and science verification will be presented. Also we describe the deployment and first on-sky tests performed between April and June 2021.

preprint2021arXiv

Crab nebula at 260 GHz with the NIKA2 polarimeter. Implications for the polarization angle calibration of future CMB experiments

The quest for primordial gravitational waves enclosed in the Cosmic Microwave Background (CMB) polarization B-modes signal motivates the development of a new generation of high sensitive experiments (e.g. CMB-S4, LiteBIRD) that would allow them to detect its imprint.Neverthless, this will be only possible by ensuring a high control of the instrumental systematic effects and an accurate absolute calibration of the polarization angle. The Crab nebula is known to be a polarization calibrator on the sky for CMB experiments, already used for the Planck satellite it exhibits a high polarized signal at microwave wavelengths. In this work we present Crab polarization observations obtained at the central frequency of 260 GHz with the NIKA2 instrument and discuss the accuracy needed on such a measurement to improve the constraints on the absolute angle calibration for CMB experiments.

preprint2021arXiv

Dust Emission in Galaxies at Millimeter Wavelengths: Cooling of star forming regions in NGC6946

Interstellar dust plays an important role in the formation of molecular gas and the heating and cooling of the interstellar medium. The spatial distribution of the mm-wavelength dust emission from galaxies is largely unexplored. The NIKA2 Guaranteed Time Project IMEGIN (Interpreting the Millimeter Emission of Galaxies with IRAM and NIKA2) has recently mapped the mm emission in the grand design spiral galaxy NGC6946. By subtracting the contributions from the free-free, synchrotron, and CO line emission, we map the distribution of the pure dust emission at 1:15mm and 2mm. Separating the arm/interarm regions, we find a dominant 2mm emission from interarms indicating the significant role of the general interstellar radiation field in heating the cold dust. Finally, we present maps of the dust mass, temperature, and emissivity index using the Bayesian MCMC modeling of the spectral energy distribution in NGC6946.

preprint2021arXiv

Exploring the millimetre emission in nearby galaxies: analysis of the edge-on galaxy NGC 891

New observations of the edge-on galaxy NGC 891, at 1.15 and 2 mm obtained with the IRAM 30-m telescope and the NIKA2 camera, within the framework of the IMEGIN (Interpreting the Millimetre Emission of Galaxies with IRAM and NIKA2) Large Program, are presented in this work. By using multiwavelength maps (from the mid-IR to the cm wavelengths) we perform SED fitting in order to extract the physical properties of the galaxy on both global and local ($\sim$kpc) scales. For the interpretation of the observations we make use of a state-of-the-art SED fitting code, HerBIE (HiERarchical Bayesian Inference for dust Emission). The observations indicate a galaxy morphology, at mm wavelengths, similar to that of the cold dust emission traced by sub-mm observations and to that of the molecular gas. The contribution of the radio emission at the NIKA2 bands is very small (negligible at 1.15 mm and $\sim10\%$ at 2 mm) while it dominates the total energy budget at longer wavelengths (beyond 5 mm). On local scales, the distribution of the free-free emission resembles that of the dust thermal emission while the distribution of the synchrotron emission shows a deficiency along the major axis of the disc of the galaxy.

preprint2021arXiv

Galactic Star Formation with NIKA2 (GASTON): Evidence of mass accretion onto dense clumps

High-mass stars ($m_* \gtrsim 8 \, M_\odot$) play a crucial role in the evolution of galaxies, and so it is imperative that we understand how they are formed. We have used the New IRAM KIDs Array 2 (NIKA2) camera on the Institut de Radio Astronomie Millimétrique (IRAM) 30-m telescope to conduct high-sensitivity continuum mapping of $\sim2$ deg$^2$ of the Galactic plane (GP) as part of the Galactic Star Formation with NIKA2 (GASTON) large program. We have identified a total of 1467 clumps within our deep 1.15 mm continuum maps and, by using overlapping continuum, molecular line, and maser parallax data, we have determined their distances and physical properties. By placing them upon an approximate evolutionary sequence based upon 8 $μ$m $\textit{Spitzer}$ imaging, we find evidence that the most massive dense clumps accrete material from their surrounding environment during their early evolution, before dispersing as star formation advances, supporting clump-fed models of high-mass star formation.

preprint2021arXiv

Galactic star formation with NIKA2 (GASTON): Filament convergence and its link to star formation

In the past decade filaments have been recognised as a major structural element of the interstellar medium, the densest of these filaments hosting the formation of most stars. In some star-forming molecular clouds converging networks of filaments, also known as hub filament systems, can be found. These hubs are believed to be preferentially associated to massive star formation. As of today, there are no metrics that allow the systematic quantification of a filament network convergence. Here, we used the IRAM 30m NIKA2 observations of the Galactic plane from the GASTON large programme to systematically identify filaments and produce a filament convergence parameter map. We use such a map to show that: i. hub filaments represent a small fraction of the global filament population; ii. hubs host, in proportion, more massive and more luminous compact sources that non-hubs; iii. hub-hosting clumps are more evolved that non-hubs; iv. no discontinuities are observed in the properties of compact sources as a function of convergence parameter. We propose that the rapid global collapse of clumps is responsible for (re)organising filament networks into hubs and, in parallel, enhancing the mass growth of compact sources.

preprint2021arXiv

GASTON: Galactic Star Formation with NIKA2. Evidence for the mass growth of star-forming clumps

Determining the mechanism by which high-mass stars are formed is essential for our understanding of the energy budget and chemical evolution of galaxies. By using the New IRAM KIDs Array 2 (NIKA2) camera on the Institut de Radio Astronomie Millimétrique (IRAM) 30-m telescope, we have conducted high-sensitivity and large-scale mapping of a fraction of the Galactic plane in order to search for signatures of the transition between the high- and low-mass star-forming modes. Here, we present the first results from the Galactic Star Formation with NIKA2 (GASTON) project, a Large Programme at the IRAM 30-m telescope which is mapping $\approx$2 deg$^2$ of the inner Galactic plane (GP), centred on $\ell$=23.9$^\circ$, $b$=0.05$^\circ$, as well as targets in Taurus and Ophiuchus in 1.15 and 2.00 mm continuum wavebands. In this paper we present the first of the GASTON GP data taken, and present initial science results. We conduct an extraction of structures from the 1.15 mm maps using a dendrogram analysis and, by comparison to the compact source catalogues from Herschel survey data, we identify a population of 321 previously-undetected clumps. Approximately 80 per cent of these new clumps are 70 $μ$m-quiet, and may be considered as starless candidates. We find that this new population of clumps are less massive and cooler, on average, than clumps that have already been identified. Further, by classifying the full sample of clumps based upon their infrared-bright fraction - an indicator of evolutionary stage - we find evidence for clump mass growth, supporting models of clump-fed high-mass star formation.

preprint2021arXiv

Mapping the intracluster medium temperature in the era of NIKA2 and MUSTANG-2

We present preliminary results from an on-going program that aims at mapping the intracluster medium (ICM) temperature of high redshift galaxy clusters from the MaDCoWS sample using a joint analysis of shallow X-ray data obtained by $Chandra$ and high angular resolution Sunyaev-Zel'dovich (SZ) observations realized with the NIKA2 and MUSTANG-2 cameras. We also present preliminary results from an on-going Open Time program within the NIKA2 collaboration that aims at mapping the ICM temperature of a galaxy cluster at $z=0.45$ from the resolved detection of the relativistic corrections to the SZ spectrum. These studies demonstrate how high angular resolution SZ observations will play a major role in the coming decade to push the investigation of ICM dynamics and non-gravitational processes to high redshift before the next generation X-ray observatories come into play.

preprint2021arXiv

Multi-probe analysis of the galaxy cluster CL J1226.9+3332: hydrostatic mass and hydrostatic-to-lensing bias

We present a multi-probe analysis of the well-known galaxy cluster CL J1226.9+3332 as a proof of concept for multi-wavelength studies within the framework of the NIKA2 Sunyaev-Zeldovich Large Program (LPSZ). CL J1226.9+3332 is a massive and high redshift (z = 0.888) cluster that has already been observed at several wavelengths. A joint analysis of the thermal SZ (tSZ) effect at millimeter wavelength with the NIKA2 camera and in X-ray with the XMM-Newton satellite permits the reconstruction of the cluster thermodynamical properties and mass assuming hydrostatic equilibrium. We test the robustness of our mass estimates against different definitions of the data analysis transfer function. Using convergence maps reconstructed from the data of the CLASH program we obtain estimates of the lensing mass, which we compare to the estimated hydrostatic mass. This allows us to measure the hydrostatic-to-lensing mass bias and the associated systematic effects related to the NIKA2 measurement. We obtain M500HSE = (7.65 +- 1.03) 1014 Msun and M500lens = (7.35 +- 0.65) 1014 Msun, which implies a HSE-to-lensing bias consistent with 0 within 20 percent.

preprint2021arXiv

Observations with KIDs Interferometer Spectrum Survey(KISS)

We describe the preliminary on-sky results of the KIDs Interferometer Spectrum Survey (KISS), a spectral imager with a 1 deg field of view (FoV). The instrument operates in the range 120-180 GHz from the 2.25 m Q-U-I JOint TEnerife telescope in Teide Observatory (Tenerife, Canary Islands), at 2 395 m altitude above sea level. Spectra at low resolution, up to 1.45 GHz, are obtained using a fast (3.72 Hz mechanical frequency) Fourier transform spectrometer, coupled to a continuous dilution cryostat with a stabilized temperature of 170 mK that hosts two 316-pixel arrays of lumped-element kinetic inductance detectors. KISS generates more than 3 000 spectra per second during observations and represents a pathfinder to demonstrate the potential for spectral mapping with large FoV. We give an overall description of the spectral mapping paradigm and we present recent results from observations, in this paper.

preprint2021arXiv

Overdensity of SubMillimiter Galaxies in the GJ526 Field mapped with the NIKA2 Camera

Using the NIKA2 dual band millimeter camera installed on the IRAM30m telescope, we have mapped a relatively large field (~70 arcmin^2) in the direction of the star GJ526 to investigate the nature of the sources found with the MAMBO camera at 1.2 mm ten years earlier. We have found that they must be dust-obscured galaxies (SMGs) in the background beyond the star. The new NIKA2 map at 1.15 mm reveals additional sources and, in fact, an overdensity of SMGs predominantly distributed along a filament-like structure in projection on the sky across the whole observed field. We speculate this might be a cosmic filament at high redshift as revealed in cosmological hydrodynamical simulations. Measurement of spectroscopic redshifts of the SMGs in the candidate filament is required now for a definitive confirmation of the nature of the structure.

preprint2021arXiv

Probing the role of magnetic fields in star-forming filaments: NIKA2-Pol commissioning results toward OMC-1

Dust polarization observations are a powerful, practical tool to probe the geometry (and to some extent, the strength) of magnetic fields in star-forming regions. In particular, Planck polarization data have revealed the importance of magnetic fields on large scales in molecular clouds. However, due to insufficient resolution, Planck observations are unable to constrain the B-field geometry on prestellar and protostellar scales. The high angular resolution of 11.7 arcsec provided by NIKA2-Pol 1.15 mm polarimetric imaging, corresponding to $\sim$ 0.02 pc at the distance of the Orion molecular cloud (OMC), makes it possible to advance our understanding of the B-field morphology in star-forming filaments and dense cores (IRAM 30m large program B-FUN). The commissioning of the NIKA2-Pol instrument has led to several challenging issues, in particular, the instrumental polarization or intensity-to-polarization (leakage) effect. In the present paper, we illustrate how this effect can be corrected for, leading to reliable exploitable data in a structured, extended source such as OMC-1. We present a statistical comparison between NIKA2-Pol and SCUBA2-Pol2 results in the OMC-1 region. We also present tentative evidence of local pinching of the B-field lines near Orion-KL, in the form of a new small-scale hourglass pattern, in addition to the larger-scale hourglass already seen by other instruments such as Pol2.

preprint2021arXiv

PSZ2G091:A massive double cluster at z=0.822 observed by the NIKA2 camera

PSZ2 G091.83+26.11 is a massive galaxy cluster with M500 = 7.43 x 10^14 Msun at z = 0.822. This object exhibits a complex morphology with a clear bimodality observed in X-rays. However, it was detected and analysed in the Planck sample as a single, spherical cluster following a universal profile [1]. This model can lead to miscalculations of thermodynamical quantities, like the pressure profile. As future multiwavelength cluster experiments will detect more and more objects at higher redshifts (where we expect the fraction of merging objects to be higher), it is crucial to quantify this systematic effect. In this work, we use high-resolution observations of PSZ2 G091.83+26.11 by the NIKA2 camera to integrate the morphological characteristics of the cluster in our modelling. This is achieved by fitting a two-halo model to the SZ image and then by reconstruction of the resulting projected pressure profile. We then compare these results with the spherical assumption.

preprint2021arXiv

Searching for high-z DSFGs with NIKA2 and NOEMA

As the possible progenitors of passive galaxies at z=2-3, dusty star-forming galaxies (DSFGs) at z>4 provide a unique perspective to study the formation, assembly, and early quenching of massive galaxies in the early Universe. The extreme obscuration in optical-IR makes (sub)mm spectral scans the most universal and unbiased way to confirm/exclude the high-z nature of candidate dusty star-forming galaxies. We present here the status of the NIKA2 Cosmological Legacy Survey (N2CLS), which is the deepest wide-area single-dish survey in the millimeter searching for high-z DSFGs. We also introduce a joint-analysis method to efficiently search for the spectroscopic redshift of high-z DSFGs with noisy spectra and photometric data and present its success in identifying the redshift of DSFGs found in NIKA2 science verification data.

preprint2021arXiv

The LPSZ-CLASH galaxy cluster sample: combining lensing and hydrostatic mass estimates

Starting from the clusters included in the NIKA sample and in the NIKA2 Sunyaev-Zel'dovich Large Program (LPSZ) we have selected a sample of six common objects with the Cluster Lensing And Supernova survey with Hubble (CLASH) lensing data. For the LPSZ clusters we have at our disposal both high-angular resolution observations of the thermal SZ with NIKA and NIKA2 and X-ray observations with XMM-Newton from which hydrostatic mass estimates can be derived. In addition, the CLASH dataset includes lensing convergence maps that can be converted into lensing estimates of the total mass of the cluster. One-dimensional mass profiles are used to derive integrated mass estimates accounting for systematic effects (data processing, modeling, etc.). Two-dimensional analysis of the maps can reveal substructures in the cluster and, therefore, inform us about the dynamical state of each system. Moreover, we are able to study the hydrostatic mass to lensing mass bias, across different morphology and a range of redshift clusters to give more insight on the hydrostatic mass bias. The analysis presented in this proceeding follows the study discussed in Ferragamo et al. 2021.

preprint2021arXiv

The NIKA2 Sunyaev-Zeldovich Large Program

The NIKA2 Guaranteed-Time SZ Large Program (LPSZ) is dedicated to the high-angular resolution SZ mapping of a representative sample of 45 SZ-selected galaxy clusters drawn from the catalogues of the Planck satellite, or of the Atacama Cosmology Telescope. The LPSZ sample spans a mass range from $3$ to $11 \times 10^{14} M_{\odot}$ and a redshift range from $0.5$ to $0.9$, extending to higher redshift and lower mass the previous samples dedicated to the cluster mass calibration and universal properties estimation. The main goals of the LPSZ are the measurement of the average radial profile of the ICM pressure up to $R_{500}$ by combining NIKA2 with Planck or ACT data, and the estimation of the scaling law between the SZ observable and the mass using NIKA2, XMM-Newton and Planck/ACT data. Furthermore, combining LPSZ data with existing or forthcoming public data in lensing, optical/NIR or radio domains, we will build a consistent picture of the cluster physics and further gain knowledge on the mass estimate as a function of the cluster morphology and dynamical state.

preprint2020arXiv

Calibration and Performance of the NIKA2 camera at the IRAM 30-meter Telescope

NIKA2 is a dual-band millimetric continuum camera of 2900 Kinetic Inductance Detectors (KID), operating at $150$ and $260\,\rm{GHz}$, installed at the IRAM 30-meter telescope. We present the performance assessment of NIKA2 after one year of observation using a dedicated point-source calibration method, referred to as the \emph{baseline} method. Using a large data set acquired between January 2017 and February 2018 that span the whole range of observing elevations and atmospheric conditions encountered at the IRAM 30-m telescope, we test the stability of the performance parameters. We report an instantaneous field of view (FOV) of 6.5' in diameter, filled with an average fraction of $84\%$ and $90\%$ of valid detectors at $150$ and $260\,\rm{GHz}$, respectively. The beam pattern is characterized by a FWHM of $17.6'' \pm 0.1''$ and $11.1''\pm 0.2''$, and a beam efficiency of $77\% \pm 2\%$ and $55\% \pm 3\%$ at $150$ and $260\,\rm{GHz}$, respectively. The rms calibration uncertainties are about $3\%$ at $150\,\rm{GHz}$ and $6\%$ at $260\,\rm{GHz}$. The absolute calibration uncertainties are of $5\%$ and the systematic calibration uncertainties evaluated at the IRAM 30-m reference Winter observing conditions are below $1\%$ in both channels. The noise equivalent flux density (NEFD) at $150$ and $260\,\rm{GHz}$ are of $9 \pm 1\, \rm{mJy}\cdot s^{1/2}$ and $30 \pm 3\, \rm{mJy}\cdot s^{1/2}$. This state-of-the-art performance confers NIKA2 with mapping speeds of $1388 \pm 174$ and $111 \pm 11 \,\rm{arcmin}^2\cdot \rm{mJy}^{-2}\cdot \rm{h}^{-1}$ at $150$ and $260\,\rm{GHz}$. With these unique capabilities of fast dual-band mapping at high (better that 18'') angular resolution, NIKA2 is providing an unprecedented view of the millimetre Universe.

preprint2020arXiv

Cluster cosmology with the NIKA2 SZ Large Program

The main limiting factor of cosmological analyses based on thermal Sunyaev-Zel'dovich (SZ) cluster statistics comes from the bias and systematic uncertainties that affect the estimates of the mass of galaxy clusters. High-angular resolution SZ observations at high redshift are needed to study a potential redshift or morphology dependence of both the mean pressure profile and of the mass-observable scaling relation used in SZ cosmological analyses. The NIKA2 camera is a new generation continuum instrument installed at the IRAM 30-m telescope. With a large field of view, a high angular resolution and a high-sensitivity, the NIKA2 camera has unique SZ mapping capabilities. In this paper, we present the NIKA2 SZ large program, aiming at observing a large sample of clusters at redshifts between 0.5 and 0.9, and the characterization of the first cluster oberved with NIKA2.

preprint2020arXiv

Exploiting NIKA2/XMM-Newton imaging synergy for intermediate mass, high-$z$ galaxy clusters within the NIKA2 SZ Large Program

High-resolution mapping of the intra-cluster medium (ICM) up to high redshift and down to low masses is crucial to derive accurate mass estimates of the galaxy cluster and to understand the systematic effects affecting cosmological studies based on galaxy clusters. We present a spatially-resolved Sunyaev-Zel'dovich (SZ)/X-ray analysis of ACT-CL J0215.4+0030, a high redshift ($z=0.865$) galaxy cluster of intermediate mass ($M_{500}\simeq3.5\times10^{14}\;\mathrm{M_\odot}$) observed as part of the ongoing NIKA2 SZ Large Program, a follow up of a representative sample of objects at $0.5 \leqslant z \leqslant 0.9$. In addition to the faintness and small angular size induced by its mass and redshift, the cluster is contaminated by point sources that significantly affect the SZ signal. Therefore, this is an interesting case study for the most challenging sources of the NIKA2 cluster sample. We present the NIKA2 observations of this cluster and the resulting data. We reconstruct the ICM pressure profile by performing a joint analysis of the SZ signal and of the point sources in the NIKA2 150 GHz map. We obtain high-quality estimates of the ICM thermodynamical properties with NIKA2. We compare the pressure profile extracted from the NIKA2 map to the pressure profile obtained from X-ray data only by deprojecting XMM-Newton observations of the cluster. We combine the NIKA2 pressure profile with the X-ray deprojected density to extract detailed information on the ICM. The radial distribution of its thermodynamic properties indicate that the cluster has a disturbed core. The hydrostatic mass of the cluster is to be compatible with estimations from SZ and X-rays scaling relations. We conclude that the NIKA2 SZ large program can deliver quality information on the thermodynamics of the ICM even for one of its faintest clusters, after a careful treatment of the contamination by point sources.

preprint2020arXiv

KISS: a spectrometric imager for millimetre cosmology

Clusters of galaxies are used to map the large-scale structures in the universe and as probe of universe evolution. They can be observed through the Sunyaev-Zel'dovich (SZ) effect. At this respect the spectro-imaging at low resolution frequency is an important tool, today, for the study of cluster of galaxies. We have developed KISS (KIDs-Interferometer-Spectrum-Survey), a spectrometric imager dedicated to the secondary anisotropies of the Cosmic Microwave Background (CMB). The multi-frequency approach permits to improve the component separation with respect to predecessor experiments. In this paper, firstly, we provide a description of the scientific context and the state of the art of SZ observations. Secondly, we describe the KISS instrument. Finally, we show preliminary results of the ongoing commissioning campaign.

preprint2019arXiv

A low-mass galaxy cluster as a test-case study for the NIKA2 SZ Large Program

High-resolution mapping of the hot gas in galaxy clusters is a key tool for cluster-based cosmological analyses. Taking advantage of the NIKA2 millimeter camera operated at the IRAM 30-m telescope, the NIKA2 SZ Large Program seeks to get a high-resolution follow-up of 45 galaxy clusters covering a wide mass range at high redshift in order to re-calibrate some of the tools needed for the cosmological exploitation of SZ surveys. We present the second cluster analysis of this program, targeting one of the faintest sources of the sample in order to tackle the difficulties in data reduction for such faint, low-SNR clusters. In this study, the main challenge is the precise estimation of the contamination by sub-millimetric point sources, which greatly affects the tSZ map of the cluster. We account for this contamination by performing a joint fit of the SZ signal and of the flux density of the compact sources. A prior knowledge of these fluxes is given by the adjustment of the SED of each source using data from both NIKA2 and the \textit{Herschel} satellite. The first results are very promising and demonstrate the possibility to estimate thermodynamic properties with NIKA2, even in a compact cluster heavily contaminated by point sources.

preprint2019arXiv

Debris disks around stars in the NIKA2 era

The new NIKA2 camera at the IRAM 30m radiotelescope was used to observe three known debris disks in order to constrain the SED of their dust emission in the millimeter wavelength domain. We have found that the spectral index between the two NIKA2 bands (1mm and 2mm) is consistent with the Rayleigh-Jeans regime (lambda^{-2}), unlike the steeper spectra (lambda^{-3}) measured in the submillimeter-wavelength domain for two of the three disks $-$ around the stars Vega and HD107146. We provide a succesful proof of concept to model this spectral inversion in using two populations of dust grains, those smaller and those larger than a grain radius a0 of 0.5mm. This is obtained in breaking the slope of the size distribution and the functional form of the absorption coefficient of the standard model at a0. The third disk - around the star HR8799 - does not exhibit this spectral inversion but is also the youngest.

preprint2019arXiv

GASTON: Galactic Star Formation with NIKA2: A new population of cold massive sources discovered

Understanding where and when the mass of stars is determined is one of the fundamental, mostly unsolved, questions in astronomy. Here, we present the first results of GASTON, the Galactic Star Formation with NIKA2 large programme on the IRAM 30m telescope, that aims to identify new populations of low-brightness sources to tackle the question of stellar mass determination across all masses. In this paper, we focus on the high-mass star formation part of the project, for which we map a $\sim2$ deg$^2$ region of the Galactic plane around $l=24^\circ$ in both 1.2 mm and 2.0 mm continuum. Half-way through the project, we reach a sensitivity of 3.7 mJy/beam at 1.2mm. Even though larger than our target sensitivity of 2 mJy, the current sensitivity already allows the identification of a new population of cold, compact sources that remained undetected in any (sub-)mm Galactic plane survey so far. In fact, about 25% of the $\sim 1600$ compact sources identified in the 1.2 mm GASTON image are new detections. We present a preliminary analysis of the physical properties of the GASTON sources as a function of their evolutionary stage, arguing for a potential evolution of the mass distribution of these sources with time.

preprint2019arXiv

Mapping the gas thermodynamic properties of the massive cluster merger MOO J1142$+$1527 at z = 1.2

We present the results of the analysis of the very massive cluster MOO J1142$+$1527 at a redshift $z = 1.2$ based on high angular resolution NIKA2 Sunyaev-Zel'dovich (SZ) and $Chandra$ X-ray data. This multi-wavelength analysis enables us to estimate the shape of the temperature profile with unprecedented precision at this redshift and to obtain a map of the gas entropy distribution averaged along the line of sight. The comparison between the cluster morphological properties observed in the NIKA2 and $Chandra$ maps together with the analysis of the entropy map allows us to conclude that MOO J1142$+$1527 is an on-going merger hosting a cool-core at the position of the X-ray peak. This work demonstrates how the addition of spatially-resolved SZ observations to low signal-to-noise X-ray data can bring valuable insights on the intracluster medium thermodynamic properties at $z>1$.

preprint2019arXiv

NIKA: a mm camera for Sunyaev-Zel'dovich science in clusters of galaxies

Clusters of galaxies, the largest bound objects in the Universe, constitute a cosmological probe of choice, which is sensitive to both dark matter and dark energy. Within this framework, the Sunyaev-Zel'dovich (SZ) effect has opened a new window for the detection of clusters of galaxies and for the characterization of their physical properties such as mass, pressure and temperature. NIKA, a KID-based dual band camera installed at the IRAM 30-m telescope, was particularly well adapted in terms of frequency, angular resolution, field-of-view and sensitivity, for the mapping of the thermal and kinetic SZ effect in high-redshift clusters. In this paper, we present the NIKA cluster sample and a review of the main results obtained via the measurement of the SZ effect on those clusters: reconstruction of the cluster radial pressure profile, mass, temperature and velocity.

preprint2019arXiv

NIKA2 mapping and cross-instrument SED extraction of extended sources with Scanamorphos

The steps taken to tailor to NIKA2 observations the Scanamorphos algorithm (initially developed to subtract low-frequency noise from Herschel on-the-fly observations) are described, focussing on the consequences of the different instrument architecture and observation strategy. The method, making the most extensive use of the redundancy built in the multi-scan coverage with large arrays of a given region of the sky, is applicable to extended sources, while the pipeline is so far optimized for compact sources. An example of application is given. A related tool to build consistent broadband SEDs from 60 microns to 2 mm, combining Herschel and NIKA2 data, has also been developed. Its main task is to process the data least affected by low-frequency noise and coverage limitations (i.e. the Herschel data) through the same transfer function as the NIKA2 data, simulating the same scan geometry and applying the same noise and atmospheric signal as extracted from the 1 mm and 2 mm data.

preprint2019arXiv

Observing with NIKA2Pol from the IRAM 30m telescope. Early results on the commissioning phase

The NIKA2 polarization channel at 260 GHz (1.15 mm) has been proposed primarily to observe galactic star-forming regions and probe the critical scales between 0.01-0.05 pc at which magnetic field lines may channel the matter of interstellar filaments into growing dense cores. The NIKA2 polarimeter consists of a room temperature continuously rotating multi-mesh HWP and a cold polarizer that separates the two orthogonal polarizations onto two 260 GHz KIDs arrays. We describe in this paper the preliminary results obtained during the most recent commissioning campaign performed in December 2018. We concentrate here on the analysis of the extended sources, while the observation of compact sources is presented in a companion paper [12]. We present preliminary NIKA2 polarization maps of the Crab nebula. We find that the integrated polarization intensity flux measured by NIKA2 is consistent with expectations.In terms of polarization angle, we are still limited by systematic uncertainties that will be further investigated in the forthcoming commissioning campaigns.

preprint2019arXiv

The KISS experiment

Mapping millimetre continuum emission has become a key issue in modern multi-wavelength astrophysics. In particular, spectrum-imaging at low frequency resolution is an asset for characterizing the clusters of galaxies via the Sunyaev Zeldovich (SZ) effect. In this context, we have built a ground-based spectrum-imager named KIDs Interferometer Spectrum Survey (KISS). This instrument is based on two 316-pixel arrays of Kinetic Inductance Detectors (KID) cooled to 150 mK by a custom dilution refrigerator-based cryostat. By using Ti-Al and Al absorbers, we can cover a wide frequency range between 80 and 300 GHz. In order to preserve a large instantaneous Field of View (FoV) 1 degree the spectrometer is based on a Fourier Transform interferometer. This represents a technological challenge due to the fast scanning speed that is needed to overcome the effects of background atmospheric fluctuations. KISS is installed at the QUIJOTE 2.25 m telescope in Tenerife since February 2019 and is currently in its commissioning phase. In this proceeding we present an overview of the instrument and the latest results.

preprint2019arXiv

The NIKA polarimeter on science targets. Crab nebula observations at 150 GHz and dual-band polarization images of Orion Molecular Cloud OMC-1

We present here the polarization system of the NIKA camera and give a summary of the main results obtained and performed studies on Orion and the Crab nebula. The polarization system was equipped with a room temperature continuously rotating multi-mesh half wave plate and a grid polarizer facing the NIKA cryostat window. NIKA even though less sensitive than NIKA2 had polarization capability in both 1 and 2 millimiter bands. NIKA polarization observations demonstrated the ability of such a technology in detecting the polarization of different targets, compact and extended sources like the Crab nebula and Orion Molecular Cloud region OMC-1. These measurements together with the developed techniques to deal with systematics, opened the way to the current observations of NIKA2 in polarization that will provide important advances in the studies of galactic and extra-galactic emission and magnetic fields.

preprint2019arXiv

Unveiling the merger dynamics of the most massive MaDCoWS cluster at $z = 1.2$ from a multi-wavelength mapping of its intracluster medium properties

The characterization of the Intra-Cluster Medium (ICM) properties of high-redshift galaxy clusters is fundamental to our understanding of large-scale structure formation processes. We present the results of a multi-wavelength analysis of the very massive cluster MOO J1142$+$1527 at a redshift $z = 1.2$ discovered as part of the Massive and Distant Clusters of WISE Survey (MaDCoWS). This analysis is based on high angular resolution $Chandra$ X-ray and NIKA2 Sunyaev-Zel'dovich (SZ) data. Although the X-ray data have only about 1700 counts, we are able to determine the ICM thermodynamic radial profiles, namely temperature, entropy, and hydrostatic mass. These have been obtained with unprecedented precision at this redshift and up to $0.7R_{500}$, thanks to the combination of high-resolution X-ray and SZ data. The comparison between the galaxy distribution mapped in infrared by $Spitzer$ and the morphological properties of the ICM derived from the combined analysis of the $Chandra$ and NIKA2 data leads us to the conclusion that the cluster is an on-going merger. We measure the hydrostatic mass profile of the cluster in four angular sectors centered on the large-scale X-ray centroid. This allows us to estimate a systematic uncertainty on the cluster total mass that characterizes both the impact of the observed deviations from spherical symmetry and of the core dynamics on the mass profile. We further combine the X-ray and SZ data at the pixel level to obtain maps of the temperature and entropy distributions averaged along the line of sight. We find a relatively low entropy core at the position of the X-ray peak and high temperature regions located on its south and west sides. The increase in ICM temperature at the location of the SZ peak is expected given the merger dynamics. (abridged)

preprint2018arXiv

NIKA 150 GHz polarization observations of the Crab nebula and its spectral energy distribution

The Crab nebula is a supernova remnant exhibiting a highly polarized synchrotron radiation at radio and millimeter wavelengths. It is the brightest source in the microwave sky with an extension of 7 by 5 arcminutes and commonly used as a standard candle for any experiment which aims at measuring the polarization of the sky. Though its spectral energy distribution has been well characterized in total intensity, polarization data are still lacking at millimetre wavelengths. We report in this paper high resolution (18 arcsec FWHM) observations of the Crab nebula in total intensity and linear polarization at 150 GHz with the NIKA camera. NIKA, operated at the IRAM 30 m telescope from 2012 to 2015, is a camera made of Lumped Element Kinetic Inductance Detectors (LEKIDs) observing the sky at 150 and 260 GHz. From these observations we are able to reconstruct the spatial distribution of the polarization degree and angle of the Crab nebula, which is found to be compatible with previous observations at lower and higher frequencies. Averaging across the source and using other existing data sets we find that the Crab nebula polarization angle is consistent with being constant over a wide range of frequencies with a value of -87.7$^\circ$ +- 0.3 in Galactic coordinates. We also present the first estimation of the Crab nebula spectral energy distribution polarized flux in a wide frequency range: 30-353 GHz. Assuming a single power law emission model we find that the polarization spectral index $β_{pol}$ = - 0.347 +- 0.026 is compatible with the intensity spectral index $β$ = - 0.323 +- 0.001.

preprint2016arXiv

High angular resolution Sunyaev-Zel'dovich observations of MACS J1423.8+2404 with NIKA: Multiwavelength analysis

The prototype of the NIKA2 camera, NIKA, is an instrument operating at the IRAM 30-m telescope, which can observe simultaneously at 150 and 260GHz. One of the main goals of NIKA2 is to measure the pressure distribution in galaxy clusters at high resolution using the thermal SZ (tSZ) effect. Such observations have already proved to be an excellent probe of cluster pressure distributions even at high redshifts. However, an important fraction of clusters host submm and/or radio point sources, which can significantly affect the reconstructed signal. Here we report on <20" resolution observations at 150 and 260GHz of the cluster MACSJ1424, which hosts both radio and submm point sources. We examine the morphology of the tSZ signal and compare it to other datasets. The NIKA data are combined with Herschel satellite data to study the SED of the submm point source contaminants. We then perform a joint reconstruction of the intracluster medium (ICM) electronic pressure and density by combining NIKA, Planck, XMM-Newton, and Chandra data, focusing on the impact of the radio and submm sources on the reconstructed pressure profile. We find that large-scale pressure distribution is unaffected by the point sources because of the resolved nature of the NIKA observations. The reconstructed pressure in the inner region is slightly higher when the contribution of point sources are removed. We show that it is not possible to set strong constraints on the central pressure distribution without accurately removing these contaminants. The comparison with X-ray only data shows good agreement for the pressure, temperature, and entropy profiles, which all indicate that MACSJ1424 is a dynamically relaxed cool core system. The present observations illustrate the possibility of measuring these quantities with a relatively small integration time, even at high redshift and without X-ray spectroscopy.

preprint2016arXiv

High angular resolution SZ observations with NIKA and NIKA2

NIKA2 (New IRAM KID Arrays) is a dual band (150 and 260 GHz) imaging camera based on Kinetic Inductance Detectors (KIDs) and designed to work at the IRAM 30 m telescope (Pico Veleta, Spain). Built on the experience of the NIKA prototype, NIKA2 has been installed at the 30 m focal plane in October 2015 and the commissioning phase is now ongoing. Through the thermal Sunyaev-Zeldovich (tSZ) effect, NIKA2 will image the ionized gas residing in clusters of galaxies with a resolution of 12 and 18 arcsec FWHM (at 150 and 260 GHz, respectively). We report on the recent tSZ measurements with the NIKA camera and discuss the future objectives for the NIKA2 SZ large Program, 300h of observation dedicated to SZ science. With this program we intend to perform a high angular resolution follow-up of a cosmologically-representative sample of clusters belonging to SZ catalogues, with redshift greater than 0.5. The main output of the program will be the study of the redshift evolution of the cluster pressure profile as well as that of the scaling laws relating the cluster global properties.

preprint2016arXiv

High-resolution tSZ cartography of clusters of galaxies with NIKA at the IRAM 30-m telescope

The thermal Sunyaev-Zeldovich effect (tSZ) is a powerful probe to study clusters of galaxies and is complementary with respect to X-ray, lensing or optical observations. Previous arcmin resolution tSZ observations ({\it e.g.} SPT, ACT and Planck) only enabled detailed studies of the intra-cluster medium morphology for low redshift clusters ($z < 0.2$). Thus, the development of precision cosmology with clusters requires high angular resolution observations to extend the understanding of galaxy cluster towards high redshift. NIKA2 is a wide-field (6.5 arcmin field of view) dual-band camera, operated at $100 \ {\rm mK}$ and containing $\sim 3300$ KID (Kinetic Inductance Detectors), designed to observe the millimeter sky at 150 and 260 GHz, with an angular resolution of 18 and 12 arcsec respectively. The NIKA2 camera has been installed on the IRAM 30-m telescope (Pico Veleta, Spain) in September 2015. The NIKA2 tSZ observation program will allow us to observe a large sample of clusters (50) at redshift ranging between 0.5 and 1. As a pathfinder for NIKA2, several clusters of galaxies have been observed at the IRAM 30-m telescope with the NIKA prototype to cover the various configurations and observation conditions expected for NIKA2.

preprint2016arXiv

Lumped element kinetic inductance detectors maturity for space-borne instruments in the range between 80 and 180 GHz

This work intends to give the state-of-the-art of our knowledge of the performance of LEKIDs at millimetre wavelengths (from 80 to 180~GHz). We evaluate their optical sensitivity under typical background conditions and their interaction with ionising particles. Two LEKID arrays, originally designed for ground-based applications and composed of a few hundred pixels each, operate at a central frequency of 100, and 150~GHz ($Δν/ ν$ about 0.3). Their sensitivities have been characterised in the laboratory using a dedicated closed-circle 100~mK dilution cryostat and a sky simulator, allowing for the reproduction of realistic, space-like observation conditions. The impact of cosmic rays has been evaluated by exposing the LEKID arrays to alpha particles ($^{241}$Am) and X sources ($^{109}$Cd) with a readout sampling frequency similar to the ones used for Planck HFI (about 200~Hz), and also with a high resolution sampling level (up to 2~MHz) in order to better characterise and interpret the observed glitches. In parallel, we have developed an analytical model to rescale the results to what would be observed by such a LEKID array at the second Lagrangian point.

preprint2016arXiv

Microfabrication technology for large LEKID arrays : from NIKA2 to future applications

The Lumped Element Kinetic Inductance Detectors (LEKID)demonstrated full maturity in the NIKA (New IRAM KID Arrays)instrument. These results allow directly comparing LEKID performance with other competing technologies (TES, doped silicon) in the mm and sub-mm range. A continuing effort is ongoing to improve the microfabrication technologies and concepts in order to satisfy the requirements of new instruments. More precisely, future satellites dedicated to CMB (Cosmic Microwave Background) studies will require the same focal plane technology to cover, at least, the frequency range of 60 to 600 GHz. Aluminium LEKID developed for NIKA have so far demonstrated, under real telescope conditions, performance approaching photon-noise limitation in the band 120-300 GHz. By implementing superconducting bi-layers we recently demonstrated LEKID arrays working in the range 80-120 GHz and with sensitivities approaching the goals for CMB missions. NIKA itself (350 pixels) is followed by a more ambitious project requiring several thousands (3000-5000) pixels. NIKA2 has been installed in October 2015 at the IRAM 30-m telescope. We will describe in detail the technological improvements that allowed a relatively harmless 10-fold up-scaling in pixels count without degrading the initial sensitivity. In particular we will briefly describe a solution to simplify the difficult fabrication step linked to the slot-line propagation mode in coplanar waveguide.

preprint2016arXiv

MIMAC low energy electron-recoil discrimination measured with fast neutrons

MIMAC (MIcro-TPC MAtrix of Chambers) is a directional WIMP Dark Matter detector project. Direct dark matter experiments need a high level of electron/recoil discrimination to search for nuclear recoils produced by WIMP-nucleus elastic scattering. In this paper, we proposed an original method for electron event rejection based on a multivariate analysis applied to experimental data acquired using monochromatic neutron fields. This analysis shows that a $10^5$ rejection power is reachable for electron/recoil discrimination. Moreover, the efficiency was estimated by a Monte-Carlo simulation showing that a 105 electron rejection power is reached with a $86.49\pm 0.17$\% nuclear recoil efficiency considering the full energy range and $94.67\pm0.19$\% considering a 5~keV lower threshold.

preprint2016arXiv

NIKA 2: next-generation continuum/polarized camera at the IRAM 30 m telescope and its prototype

NIKA 2 (New Instrument of Kids Array) is a next generation continuum and polarized instrument successfully installed in October 2015 at the IRAM 30 m telescope on Pico-Veleta (Granada, Spain). NIKA 2 is a high resolution dual-band camera, operating with frequency multiplexed LEKIDs (Lumped Element Kinetic Inductance Detectors) cooled at 100 mK. Dual color images are obtained thanks to the simultaneous readout of a 1020 pixels array at 2 mm and 1140 x 2 pixels arrays at 1.15 mm with a final resolution of 18 and 12 arcsec respectively, and 6.5 arcmin of Field of View (FoV). The two arrays at 1.15 mm allow us to measure the linear polarization of the incoming light. This will place NIKA 2 as an instrument of choice to study the role of magnetic fields in the star formation process. The NIKA experiment, a prototype for NIKA 2 with a reduced number of detectors (about 400 LEKIDs) and FoV (1.8 arcmin), has been successfully operated at the IRAM 30 telescope in several open observational campaigns. The performance of the NIKA 2 polarization setup has been successfully validated with the NIKA prototype.

preprint2016arXiv

NIKEL_AMC: Readout electronics for the NIKA2 experiment

The New Iram Kid Arrays-2 (NIKA2) instrument has recently been installed at the IRAM 30 m telescope. NIKA2 is a state-of-art instrument dedicated to mm-wave astronomy using microwave kinetic inductance detectors (KID) as sensors. The three arrays installed in the camera, two at 1.25 mm and one at 2.05 mm, feature a total of 3300 KIDs. To instrument these large array of detectors, a specifically designed electronics, composed of 20 readout boards and hosted in three microTCA crates, has been developed. The implemented solution and the achieved performances are presented in this paper. We find that multiplexing factors of up to 400 detectors per board can be achieved with homogeneous performance across boards in real observing conditions, and a factor of more than 3 decrease in volume with respect to previous generations.

preprint2016arXiv

Readout technologies for directional WIMP Dark Matter detection

The measurement of the direction of WIMP-induced nuclear recoils is a compelling but technologically challenging strategy to provide an unambiguous signature of the detection of Galactic dark matter. Most directional detectors aim to reconstruct the dark-matter-induced nuclear recoil tracks, either in gas or solid targets. The main challenge with directional detection is the need for high spatial resolution over large volumes, which puts strong requirements on the readout technologies. In this paper we review the various detector readout technologies used by directional detectors. In particular, we summarize the challenges, advantages and drawbacks of each approach, and discuss future prospects for these technologies.

preprint2016arXiv

The NIKA2 commissioning campaign: performance and first results

The New IRAM KID Array 2 (NIKA 2) is a dual-band camera operating with three frequency-multiplexed kilopixels arrays of Lumped Element Kinetic Inductance Detectors (LEKID) cooled at 150 mK. NIKA 2 is designed to observe the intensity and polarisation of the sky at 1.15 and 2.0 mm wavelength from the IRAM 30 m telescope. The NIKA 2 instrument represents a huge step in performance as compared to the NIKA pathfinder instrument, which has already shown state-of-the-art detector and photometric performance. After the commissioning planned to be accomplished at the end of 2016, NIKA 2 will be an IRAM resident instrument for the next ten years or more. NIKA 2 should allow the astrophysical community to tackle a large number of open questions reaching from the role of the Galactic magnetic field in star formation to the discrepancy between cluster-based and CMB-based cosmology possibly induced by the unknown cluster physics. We present an overview of the commissioning phase together with some first results.

preprint2016arXiv

The NIKA2 instrument, a dual-band kilopixel KID array for millimetric astronomy

NIKA2 (New IRAM KID Array 2) is a camera dedicated to millimeter wave astronomy based upon kilopixel arrays of Kinetic Inductance Detectors (KID). The pathfinder instrument, NIKA, has already shown state-of-the-art detector performance. NIKA2 builds upon this experience but goes one step further, increasing the total pixel count by a factor $\sim$10 while maintaining the same per pixel performance. For the next decade, this camera will be the resident photometric instrument of the Institut de Radio Astronomie Millimetrique (IRAM) 30m telescope in Sierra Nevada (Spain). In this paper we give an overview of the main components of NIKA2, and describe the achieved detector performance. The camera has been permanently installed at the IRAM 30m telescope in October 2015. It will be made accessible to the scientific community at the end of 2016, after a one-year commissioning period. When this happens, NIKA2 will become a fundamental tool for astronomers worldwide.

preprint2016arXiv

Trigger and readout electronics for the STEREO experiment

The STEREO experiment will search for a sterile neutrino by measuring the anti-neutrino energy spectrum as a function of the distance from the source, the ILL nuclear reactor. A dedicated electronic system, hosted in a single microTCA crate, was designed for this experiment. It performs triggering in two stages with various selectable conditions, processing and readout via UDP/IPBUS of 68 photomultiplier signals continuously digitized at 250 MSPS. Additionally, for detector performance monitoring, the electronics allow on-line calibration by driving LED synchronously with the data acquisition. This paper describes the electronics requirements, architecture and the performances achieved.

preprint2016arXiv

UCTM2: An updated User friendly Configurable Trigger, scaler and delay Module for nuclear and particle physics

We developed a highly integrated and versatile electronic module to equip small nuclear physics experiments and lab teaching classes: the User friendly Configurable Trigger, scaler and delay Module for nuclear and particle physics (UCTM). It is configurable through a Graphical User Interface (GUI) and provides a large number of possible trigger conditions without any Hardware Description Language (HDL) required knowledge. This new version significantly enhances the previous capabilities by providing two additional features: signal digitization and time measurements. The design, performances and a typical application are presented.

preprint2015arXiv

Bi-layer Kinetic Inductance Detectors for space observations between 80-120 GHz

We have developed Lumped Element Kinetic Inductance Detectors (LEKID) sensitive in the frequency band from 80 to 120~GHz. In this work, we take advantage of the so-called proximity effect to reduce the superconducting gap of Aluminium, otherwise strongly suppressing the LEKID response for frequencies smaller than 100~GHz. We have designed, produced and optically tested various fully multiplexed arrays based on multi-layers combinations of Aluminium (Al) and Titanium (Ti). Their sensitivities have been measured using a dedicated closed-circle 100 mK dilution cryostat and a sky simulator allowing to reproduce realistic observation conditions. The spectral response has been characterised with a Martin-Puplett interferometer up to THz frequencies, and with a resolution of 3~GHz. We demonstrate that Ti-Al LEKID can reach an optical sensitivity of about $1.4$ $10^{-17}$~$W/Hz^{0.5}$ (best pixel), or $2.2$ $10^{-17}$~$W/Hz^{0.5}$ when averaged over the whole array. The optical background was set to roughly 0.4~pW per pixel, typical for future space observatories in this particular band. The performance is close to a sensitivity of twice the CMB photon noise limit at 100~GHz which drove the design of the Planck HFI instrument. This figure remains the baseline for the next generation of millimetre-wave space satellites.

preprint2015arXiv

First polarised light with the NIKA camera

NIKA is a dual-band camera operating with 315 frequency multiplexed LEKIDs cooled at 100 mK. NIKA is designed to observe the sky in intensity and polarisation at 150 and 260 GHz from the IRAM 30-m telescope. It is a test-bench for the final NIKA2 camera. The incoming linear polarisation is modulated at four times the mechanical rotation frequency by a warm rotating multi-layer Half Wave Plate. Then, the signal is analysed by a wire grid and finally absorbed by the LEKIDs. The small time constant (< 1ms ) of the LEKID detectors combined with the modulation of the HWP enables the quasi-simultaneous measurement of the three Stokes parameters I, Q, U, representing linear polarisation. In this paper we present results of recent observational campaigns demonstrating the good performance of NIKA in detecting polarisation at mm wavelength.

preprint2015arXiv

High-energy interactions in Kinetic Inductance Detectors arrays

The impacts of Cosmic Rays on the detectors are a key problem for space-based missions. We are studying the effects of such interactions on arrays of Kinetic Inductance Detectors (KID), in order to adapt this technology for use on board of satellites. Before proposing a new technology such as the Kinetic Inductance Detectors for a space-based mission, the problem of the Cosmic Rays that hit the detectors during in-flight operation has to be studied in detail. We present here several tests carried out with KID exposed to radioactive sources, which we use to reproduce the physical interactions induced by primary Cosmic Rays, and we report the results obtained adopting different solutions in terms of substrate materials and array geometries. We conclude by outlining the main guidelines to follow for fabricating KID for space-based applications.

preprint2015arXiv

Pressure distribution of the high-redshift cluster of galaxies CL J1226.9+3332 with NIKA

The thermal Sunyaev-Zel'dovich (tSZ) effect is expected to provide a low scatter mass proxy for galaxy clusters since it is directly proportional to the cluster thermal energy. The tSZ observations have proven to be a powerful tool for detecting and studying them, but high angular resolution observations are now needed to push their investigation to a higher redshift. In this paper, we report high angular (< 20 arcsec) resolution tSZ observations of the high-redshift cluster CL J1226.9+3332 (z=0.89). It was imaged at 150 and 260 GHz using the NIKA camera at the IRAM 30-meter telescope. The 150 GHz map shows that CL J1226.9+3332 is morphologically relaxed on large scales with evidence of a disturbed core, while the 260 GHz channel is used mostly to identify point source contamination. NIKA data are combined with those of Planck and X-ray from Chandra to infer the cluster's radial pressure, density, temperature, and entropy distributions. The total mass profile of the cluster is derived, and we find $M_{500} = 5.96^{+1.02}_{-0.79} $ x $10^{14} M_{\odot}$ within the radius $R_{500} = 930^{+50}_{-43}$ kpc, at a 68% confidence level. ($R_{500}$ is the radius within which the average density is 500 times the critical density at the cluster's redshift.) NIKA is the prototype camera of NIKA2, a KIDs (kinetic inductance detectors) based instrument to be installed at the end of 2015. This work is, therefore, part of a pilot study aiming at optimizing tSZ NIKA2 large programs.

preprint2014arXiv

First observation of the thermal Sunyaev-Zel'dovich effect with kinetic inductance detectors

Clusters of galaxies provide valuable information on the evolution of the Universe and large scale structures. Recent cluster observations via the thermal Sunyaev-Zel'dovich (tSZ) effect have proven to be a powerful tool to detect and study them. In this context, high resolution tSZ observations (~ tens of arcsec) are of particular interest to probe intermediate and high redshift clusters. Observations of the tSZ effect will be carried out with the millimeter dual-band NIKA2 camera, based on Kinetic Inductance Detectors (KIDs) to be installed at the IRAM 30-meter telescope in 2015. To demonstrate the potential of such an instrument, we present tSZ observations with the NIKA camera prototype, consisting of two arrays of 132 and 224 detectors that observe at 140 and 240 GHz with a 18.5 and 12.5 arcsec angular resolution, respectively. The cluster RX J1347.5-1145 was observed simultaneously at 140 and 240 GHz. We used a spectral decorrelation technique to remove the atmospheric noise and obtain a map of the cluster at 140 GHz. The efficiency of this procedure has been characterized through realistic simulations of the observations. The observed 140 GHz map presents a decrement at the cluster position consistent with the tSZ nature of the signal. We used this map to study the pressure distribution of the cluster by fitting a gNFW model to the data. Subtracting this model from the map, we confirm that RX J1347.5-1145 is an ongoing merger, which confirms and complements previous tSZ and X-ray observations. For the first time, we demonstrate the tSZ capability of KID based instruments. The NIKA2 camera with ~ 5000 detectors and a 6.5 arcmin field of view will be well-suited for in-depth studies of the intra cluster medium in intermediate to high redshifts, which enables the characterization of recently detected clusters by the Planck satellite.

preprint2014arXiv

High resolution SZ observations at the IRAM 30-m telescope with NIKA

High resolution observations of the thermal Sunyaev-Zel'dovich (tSZ) effect are necessary to allow the use of clusters of galaxies as a probe for large scale structures at high redshifts. With its high resolution and dual-band capability at millimeter wavelengths, the NIKA camera can play a significant role in this context. NIKA is based on newly developed Kinetic Inductance Detectors (KIDs) and operates at the IRAM 30m telescope, Pico Veleta, Spain. In this paper, we give the status of the NIKA camera, focussing on the KID technology. We then present observations of three galaxy clusters: RX J1347.5-1145 as a demonstrator of the NIKA capabilities and the recent observations of CL J1226.9+3332 (z = 0.89) and MACS J0717.5+3745 (z = 0.55). We also discuss prospects for the final NIKA2 camera, which will have a 6.5 arcminute field of view with about 5000 detectors in two bands at 150 and 260 GHz.

preprint2014arXiv

In situ measurement of the electron drift velocity for upcoming directional Dark Matter detectors

Three-dimensional track reconstruction is a key issue for directional Dark Matter detection and it requires a precise knowledge of the electron drift velocity. Magboltz simulations are known to give a good evaluation of this parameter. However, large TPC operated underground on long time scale may be characterized by an effective electron drift velocity that may differ from the value evaluated by simulation. In situ measurement of this key parameter is hence needed as it is a way to avoid bias in the 3D track reconstruction. We present a dedicated method for the measurement of the electron drift velocity with the MIMAC detector. It is tested on two gas mixtures: CF4 and CF4 + CHF3. The latter has been chosen for the MIMAC detector as we expect that adding CHF3 to pure CF4 will lower the electron drift velocity. This is a key point for directional Dark Matter as the track sampling along the drift field will be improved while keeping almost the same Fluorine content of the gas mixture. We show that the drift velocity at 50 mbar is reduced by a factor of about 5 when adding 30% of CHF3.

preprint2014arXiv

Latest NIKA results and the NIKA-2 project

NIKA (New IRAM KID Arrays) is a dual-band imaging instrument installed at the IRAM (Institut de RadioAstronomie Millimetrique) 30-meter telescope at Pico Veleta (Spain). Two distinct Kinetic Inductance Detectors (KID) focal planes allow the camera to simultaneously image a field-of-view of about 2 arc-min in the bands 125 to 175 GHz (150 GHz) and 200 to 280 GHz (240 GHz). The sensitivity and stability achieved during the last commissioning Run in June 2013 allows opening the instrument to general observers. We report here the latest results, in particular in terms of sensitivity, now comparable to the state-of-the-art Transition Edge Sensors (TES) bolometers, relative and absolute photometry. We describe briefly the next generation NIKA-2 instrument, selected by IRAM to occupy, from 2015, the continuum imager/polarimeter slot at the 30-m telescope.

preprint2014arXiv

Measurement of a 127 keV Neutron Field with a micro-TPC Spectrometer

In order to measure the energy of neutron fields, with energy ranging from 8 keV to 1 MeV, a new primary standard is being developed at the IRSN (Institute for Radioprotection and Nuclear Safety). This project, micro-TPC (Micro Time Projection Chamber), carried out in collaboration with the LPSC (Laboratoire de Physique Subatomique et de Cosmologie), is based on the nuclear recoil detector principle. The instrument is presented with the associated method to measure the neutron energy. This article emphasizes the proton energy calibration procedure and energy measurements of a neutron field produced at 127 keV with the IRSN facility AMANDE.

preprint2014arXiv

Measurement of the electron drift velocity for directional dark matter detectors

Three-dimensional track reconstruction is a key issue for directional Dark Matter detection. It requires a precise knowledge of the electron drift velocity. Magboltz simulations are known to give a good evaluation of this parameter. However, large TPC operated underground on long time scale may be characterized by an effective electron drift velocity that may differ from the value evaluated by simulation. In situ measurement of this key parameter is hence a way to avoid bias in the 3D track reconstruction. We present a dedicated method for the measurement of the electron drift velocity with the MIMAC detector. It is tested on two gas mixtures : $\rm CF_4$ and $\rm CF_4+CHF_3$. We also show that adding $\rm CHF_3$ allows us to lower the electron drift velocity while keeping almost the same Fluorine content of the gas mixture.

preprint2014arXiv

Performance and calibration of the NIKA camera at the IRAM 30 m telescope

The New IRAM KID Array (NIKA) instrument is a dual-band imaging camera operating with Kinetic Inductance Detectors (KID) cooled at 100 mK. NIKA is designed to observe the sky at wavelengths of 1.25 and 2.14 mm from the IRAM 30 m telescope at Pico Veleta with an estimated resolution of 13\,arcsec and 18 arcsec, respectively. This work presents the performance of the NIKA camera prior to its opening to the astrophysical community as an IRAM common-user facility in early 2014. NIKA is a test bench for the final NIKA2 instrument to be installed at the end of 2015. The last NIKA observation campaigns on November 2012 and June 2013 have been used to evaluate this performance and to improve the control of systematic effects. We discuss here the dynamical tuning of the readout electronics to optimize the KID working point with respect to background changes and the new technique of atmospheric absorption correction. These modifications significantly improve the overall linearity, sensitivity, and absolute calibration performance of NIKA. This is proved on observations of point-like sources for which we obtain a best sensitivity (averaged over all valid detectors) of 40 and 14 mJy.s$^{1/2}$ for optimal weather conditions for the 1.25 and 2.14 mm arrays, respectively. NIKA observations of well known extended sources (DR21 complex and the Horsehead nebula) are presented. This performance makes the NIKA camera a competitive astrophysical instrument.

preprint2014arXiv

The NIKA 2012-2014 observing campaigns: control of systematic effects and results

The New IRAM KID Array (NIKA) is a dual-band camera operating with frequency multiplexed arrays of Lumped Element Kinetic Inductance Detectors (LEKIDs) cooled to 100 mK. NIKA is designed to observe the intensity and polarisation of the sky at 1.25 and 2.14 mm from the IRAM 30 m telescope. We present the improvements on the control of systematic effects and astrophysical results made during the last observation campaigns between 2012 and 2014.

preprint2013arXiv

Dark Matter directional detection with MIMAC

Directional detection is a promising direct Dark Matter (DM) search strategy. The angular distribution of the nuclear recoil tracks from WIMP events should present an anisotropy in galactic coordinates. This strategy requires both a measurement of the recoil energy with a threshold of about 5 keV and 3D recoil tracks down to few millimeters. The MIMAC project, based on a \textmu-TPC matrix, with $CF_4$ and $CHF_3$, is being developed. In June 2012, a bi-chamber prototype was installed at the LSM (Laboratoire Souterrain de Modane). A preliminary analysis of the first four months data taking allowed, for the first time, the observation of recoils from the $\mathrm{^{222}Rn}$ progeny.

preprint2013arXiv

Detection of the tSZ effect with the NIKA camera

We present the first detection of the thermal Sunyaev-Zel'dovich (tSZ) effect from a cluster of galaxies performed with a KIDs (Kinetic Inductance Detectors) based instrument. The tSZ effect is a distortion of the black body CMB (Cosmic Microwave Background) spectrum produced by the inverse Compton interaction of CMB photons with the hot electrons of the ionized intra-cluster medium. The massive, intermediate redshift cluster RX J1347.5-1145 has been observed using NIKA (New IRAM KIDs arrays), a dual-band (140 and 240 GHz) mm-wave imaging camera, which exploits two arrays of hundreds of KIDs: the resonant frequencies of the superconducting resonators are shifted by mm-wave photons absorption. This tSZ cluster observation demonstrates the potential of the next generation NIKA2 instrument, being developed for the 30m telescope of IRAM, at Pico Veleta (Spain). NIKA2 will have 1000 detectors at 140GHz and 2x2000 detectors at 240GHz, providing in that band also a measurement of the linear polarization. NIKA2 will be commissioned in 2015.

preprint2013arXiv

Development of a microtpc detector as a standard instrument for low energy neutron field characterization

In order to measure energy and fluence of neutron fields, with energy ranging from 8 keV to 1 MeV, a new primary standard is being developed at the IRSN (Institute for Radioprotection and Nuclear Safety). This project, micro-TPC (Micro Time Projection Chamber), carried out in collaboration with the LPSC, is based on the nucleus recoil detector principle. The measurement strategy requires track reconstruction of recoiling nuclei down to a few keV, which can be achieved with a low pressure gaseous detector using a micro-pattern gaseous detector. A gas mixture, mainly isobutane, is used as a n-p converter to detect neutrons into the detection volume. Then electrons, coming from the ionization of the gas by the proton recoil, are collected by the pixelised anode (2D projection). A self-triggered electronics is able to perform the anode readout at a 50 MHz frequency in order to give the third dimension of the track. Then the scattering angle is deduced from this track using algorithms. The charge collection leads to the proton energy, taking into account the ionization quenching factor. This article emphasizes the neutron energy measurements of a monoenergetic neutron field produced at 127 keV. The measurements are compared to Monte Carlo simulations using realistic neutron fields and simulations of the detector response. The discrepancy between experiments and simulations is 5 keV mainly due to the calibration uncertainties of 10%.

preprint2013arXiv

MIMAC: A micro-tpc matrix for dark matter directional detection

The dark matter directional detection opens a new field in cosmology bringing the possibility to build a map of nuclear recoils that would be able to explore the galactic dark matter halo giving access to a particle characterization of such matter and the shape of the halo. The MIMAC (MIcro-tpc MAtrix of Chambers) collaboration has developed in the last years an original prototype detector based on the direct coupling of large pixelized micromegas with a devoted fast self-triggered electronics showing the feasibility of a new generation of directional detectors. The discovery potential of this search strategy is discussed and illustrated. In June 2012, the first bi-chamber prototype has been installed at Modane Underground Laboratory (LSM) and the first underground background events, the gain stability and calibration are shown.

preprint2013arXiv

MIMAC: MIcro-tpc MAtrix of Chambers for dark matter directional detection

Directional detection of non-baryonic Dark Matter is a promising search strategy for discriminating WIMP events from neutrons, the ultimate background for dark matter direct detection. This strategy requires both a precise measurement of the energy down to a few keV and 3D reconstruction of tracks down to a few mm. The MIMAC (MIcro-tpc MAtrix of Chambers) collaboration has developed in the last years an original prototype detector based on the direct coupling of large pixelized micromegas with a special developed fast self-triggered electronics showing the feasibility of a new generation of directional detectors. The first bi-chamber prototype has been installed at Modane, underground laboratory in June 2012. The first undergournd background events, the gain stability and calibration are shown. The first spectrum of nuclear recoils showing 3D tracks coming from the radon progeny is presented.

preprint2013arXiv

Niobium Silicon alloys for Kinetic Inductance Detectors

We are studying the properties of Niobium Silicon amorphous alloys as a candidate material for the fabrication of highly sensitive Kinetic Inductance Detectors (KID), optimized for very low optical loads. As in the case of other composite materials, the NbSi properties can be changed by varying the relative amounts of its components. Using a NbSi film with T_c around 1 K we have been able to obtain the first NbSi resonators, observe an optical response and acquire a spectrum in the band 50 to 300 GHz. The data taken show that this material has very high kinetic inductance and normal state surface resistivity. These properties are ideal for the development of KID. More measurements are planned to further characterize the NbSi alloy and fully investigate its potential.

preprint2013arXiv

SuperB Technical Design Report

In this Technical Design Report (TDR) we describe the SuperB detector that was to be installed on the SuperB e+e- high luminosity collider. The SuperB asymmetric collider, which was to be constructed on the Tor Vergata campus near the INFN Frascati National Laboratory, was designed to operate both at the Upsilon(4S) center-of-mass energy with a luminosity of 10^{36} cm^{-2}s^{-1} and at the tau/charm production threshold with a luminosity of 10^{35} cm^{-2}s^{-1}. This high luminosity, producing a data sample about a factor 100 larger than present B Factories, would allow investigation of new physics effects in rare decays, CP Violation and Lepton Flavour Violation. This document details the detector design presented in the Conceptual Design Report (CDR) in 2007. The R&D and engineering studies performed to arrive at the full detector design are described, and an updated cost estimate is presented. A combination of a more realistic cost estimates and the unavailability of funds due of the global economic climate led to a formal cancelation of the project on Nov 27, 2012.

preprint2013arXiv

The NIKA instrument: results and perspectives towards a permanent KID based camera for the Pico Veleta observatory

The New IRAM KIDs Array (NIKA) is a pathfinder instrument devoted to millimetric astronomy. In 2009 it was the first multiplexed KID camera on the sky; currently it is installed at the focal plane of the IRAM 30-meters telescope at Pico Veleta (Spain). We present preliminary data from the last observational run and the ongoing developments devoted to the next NIKA-2 kilopixels camera, to be commissioned in 2015. We also report on the latest laboratory measurements, and recent improvements in detector cosmetics and read-out electronics. Furthermore, we describe a new acquisition strategy allowing us to improve the photometric accuracy, and the related automatic tuning procedure.

preprint2012arXiv

A μ-TPC detector for the characterization of low energy neutron fields

The AMANDE facility produces monoenergetic neutron fields from 2 keV to 20 MeV for metrological purposes. To be considered as a reference facility, fluence and energy distributions of neutron fields have to be determined by primary measurement standards. For this purpose, a micro Time Projection Chamber is being developed to be dedicated to measure neutron fields with energy ranging from 8 keV up to 1 MeV. In this work we present simulations showing that such a detector, which allows the measurement of the ionization energy and the 3D reconstruction of the recoil nucleus, provides the determination of neutron energy and fluence of these neutron fields.

preprint2012arXiv

Development of a multifunction module for the neutron electric dipole moment experiment at PSI

Experiments aiming at measuring the neutron electric dipole moment (nEDM) are at the forefront of precision measurements and demand instrumentation of increasing sensitivity and reliability. In this paper, we report on the development of a dedicated acquisition and control electronics board for the nEDM experiment at the Paul Scherrer Institute (PSI) in Switzerland. This multifunction module is based on a FPGA (Field-programmable gate array) which allows an optimal combination of versatility and evolution capacities.

preprint2012arXiv

NIKEL: Electronics and data acquisition for kilopixels kinetic inductance camera

A prototype of digital frequency multiplexing electronics allowing the real time monitoring of microwave kinetic inductance detector (MKIDs) arrays for mm-wave astronomy has been developed. Thanks to the frequency multiplexing, it can monitor simultaneously 400 pixels over a 500 MHz bandwidth and requires only two coaxial cables for instrumenting such a large array. The chosen solution and the performances achieved are presented in this paper.

preprint2012arXiv

The ALICE EMCal L1 trigger first year of operation experience

The ALICE experiment at the LHC is equipped with an electromagnetic calorimeter (EMCal) designed to enhance its capabilities for jet, photon and electron measurement. In addition, the EMCal enables triggering on jets and photons with a centrality dependent energy threshold. After its commissioning in 2010, the EMCal Level 1 (L1) trigger was officially approved for physics data taking in 2011. After describing the L1 hardware and trigger algorithms, the commissioning and the first year of running experience, both in proton and heavy ion beams, are reviewed. Additionally, the upgrades to the original L1 trigger design are detailed.

preprint2011arXiv

A dual-band millimeter-wave kinetic inductance camera for the IRAM 30-meter telescope

Context. The Neel IRAM KIDs Array (NIKA) is a fully-integrated measurement system based on kinetic inductance detectors (KIDs) currently being developed for millimeter wave astronomy. In a first technical run, NIKA was successfully tested in 2009 at the Institute for Millimetric Radio Astronomy (IRAM) 30-meter telescope at Pico Veleta, Spain. This prototype consisted of a 27-42 pixel camera imaging at 150 GHz. Subsequently, an improved system has been developed and tested in October 2010 at the Pico Veleta telescope. The instrument upgrades included dual-band optics allowing simultaneous imaging at 150 GHz and 220 GHz, faster sampling electronics enabling synchronous measurement of up to 112 pixels per measurement band, improved single-pixel sensitivity, and the fabrication of a sky simulator to replicate conditions present at the telescope. Results. The new dual-band NIKA was successfully tested in October 2010, performing in-line with sky simulator predictions. Initially the sources targeted during the 2009 run were re-imaged, verifying the improved system performance. An optical NEP was then calculated to be around 2 \dot 10-16 W/Hz1/2. This improvement in comparison with the 2009 run verifies that NIKA is approaching the target sensitivity for photon-noise limited ground-based detectors. Taking advantage of the larger arrays and increased sensitivity, a number of scientifically-relevant faint and extended objects were then imaged including the Galactic Center SgrB2(FIR1), the radio galaxy Cygnus A and the NGC1068 Seyfert galaxy. These targets were all observed simultaneously in the 150 GHz and 220 GHz atmospheric windows.

preprint2011arXiv

Data acquisition electronics and reconstruction software for real time 3D track reconstruction within the MIMAC project

Directional detection of non-baryonic Dark Matter requires 3D reconstruction of low energy nuclear recoils tracks. A gaseous micro-TPC matrix, filled with either 3He, CF4 or C4H10 has been developed within the MIMAC project. A dedicated acquisition electronics and a real time track reconstruction software have been developed to monitor a 512 channel prototype. This autotriggered electronic uses embedded processing to reduce the data transfer to its useful part only, i.e. decoded coordinates of hit tracks and corresponding energy measurements. An acquisition software with on-line monitoring and 3D track reconstruction is also presented.

preprint2011arXiv

Dedicated front-end and readout electronics developments for real time 3D directional detection of dark matter with MIMAC

A complete dedicated electronics, from front-end to back-end, was developed to instrument a MIMAC prototype. A front end ASIC able to monitor 64 strips of pixels and to provide their individual "Time Over Threshold" information has been designed. An associated acquisition electronics and a real time track reconstruction software have been developed to monitor a 512 channel prototype. This auto-triggered electronic uses embedded processing to reduce the data transfer to its useful part only, i.e. decoded coordinates of hit tracks and corresponding energy measurements. The electronic designs, acquisition software and the results obtained are presented.

preprint2011arXiv

Design and construction of a Cherenkov imager for charge measurement of nuclear cosmic rays

A proximity focusing Cherenkov imager called CHERCAM, has been built for the charge measurement of nuclear cosmic rays with the CREAM instrument. It consists of a silica aerogel radiator plane across from a detector plane equipped with 1,600 1" diameter photomultipliers. The two planes are separated by a ring expansion gap. The Cherenkov light yield is proportional to the charge squared of the incident particle. The expected relative light collection accuracy is in the few percents range. It leads to an expected single element separation over the range of nuclear charge Z of main interest 1 < Z < 26. CHERCAM is designed to fly with the CREAM balloon experiment. The design of the instrument and the implemented technical solutions allowing its safe operation in high altitude conditions (radiations, low pressure, cold) are presented.

preprint2011arXiv

Development and validation of a 64 channel front end ASIC for 3D directional detection for MIMAC

A front end ASIC has been designed to equip the μTPC prototype developed for the MIMAC project, which requires 3D reconstruction of low energy particle tracks in order to perform directional detection of galactic Dark Matter. Each ASIC is able to monitor 64 strips of pixels and provides the "Time Over Threshold" information for each of those. These 64 digital informations, sampled at a rate of 50 MHz, can be transferred at 400MHz by eight LVDS serial links. Eight ASIC were validated on a 2x256 strips of pixels prototype.

preprint2011arXiv

Electronics and data acquisition demonstrator for a kinetic inductance camera

A prototype of digital frequency multiplexing electronics allowing the real time monitoring of kinetic inductance detector (KIDs) arrays for mm-wave astronomy has been developed. It requires only 2 coaxial cables for instrumenting a large array. For that, an excitation comb of frequencies is generated and fed through the detector. The direct frequency synthesis and the data acquisition relies heavily on a large FPGA using parallelized and pipelined processing. The prototype can instrument 128 resonators (pixels) over a bandwidth of 125 MHz. This paper describes the technical solution chosen, the algorithm used and the results obtained.

preprint2011arXiv

Micromegas detector developments for Dark Matter directional detection with MIMAC

The aim of the MIMAC project is to detect non-baryonic Dark Matter with a directional TPC using a high precision Micromegas readout plane. We will describe in detail the recent developments done with bulk Micromegas detectors as well as the characterisation measurements performed in an Argon(95%)-Isobutane(5%) mixture. Track measurements with alpha particles will be shown.

preprint2011arXiv

MIMAC : A micro-tpc matrix for directional detection of dark matter

Directional detection of non-baryonic Dark Matter is a promising search strategy for discriminating WIMP events from background. However, this strategy requires both a precise measurement of the energy down to a few keV and 3D reconstruction of tracks down to a few mm. To achieve this goal, the MIMAC project has been developed. It is based on a gaseous micro-TPC matrix, filled with CF4 and CHF3. The first results on low energy nuclear recoils (H, F) obtained with a low mono-energetic neutron field are presented. The discovery potential of this search strategy is discussed and illustrated by a realistic case accessible to MIMAC.

preprint2011arXiv

MIMAC: A micro-tpc matrix project for directional detection of dark matter

Directional detection of non-baryonic DarkMatter is a promising search strategy for discriminating WIMP events from background ones. This strategy requires both a measurement of the recoil energy down to a few keV and 3D reconstruction of tracks down to a few mm. The MIMAC project, based on a micro-TPC matrix, filled with CF4 and CHF3 is being developed. The first results of a chamber prototype of this matrix, on low energy nuclear recoils (1H and 19F) obtained with mono-energetic neutron fields are presented. The discovery potential of this search strategy is illustrated by a realistic case accessible to MIMAC.

preprint2011arXiv

Quenching factor measurement in low pressure gas detector for directional dark matter search

There is considerable experimental effort dedicated to the directional detection of particle dark matter. Gaseous mu-TPC detectors present the privileged features of being able to reconstruct the track and the energy of the recoil nucleus following the interaction. A precise measurement of the recoil energy is a key point for the directional search strategy. Quenching has to be taken into account, i.e. only a certain fraction of the recoil energy is deposited in the ionization channel. Measurements of the ionization quenching factor for different gas mixture at room temperature have been made with a dedicated ion beam facility at the LPSC of Grenoble.

preprint2011arXiv

Status of the Super-B factory Design

The SuperB international team continues to optimize the design of an electron-positron collider, which will allow the enhanced study of the origins of flavor physics. The project combines the best features of a linear collider (high single-collision luminosity) and a storage-ring collider (high repetition rate), bringing together all accelerator physics aspects to make a very high luminosity of 10$^{36}$ cm$^{-2}$ sec$^{-1}$. This asymmetric-energy collider with a polarized electron beam will produce hundreds of millions of B-mesons at the $Υ$(4S) resonance. The present design is based on extremely low emittance beams colliding at a large Piwinski angle to allow very low $β_y^\star$ without the need for ultra short bunches. Use of crab-waist sextupoles will enhance the luminosity, suppressing dangerous resonances and allowing for a higher beam-beam parameter. The project has flexible beam parameters, improved dynamic aperture, and spin-rotators in the Low Energy Ring for longitudinal polarization of the electron beam at the Interaction Point. Optimized for best colliding-beam performance, the facility may also provide high-brightness photon beams for synchrotron radiation applications.

preprint2011arXiv

UCTM: A User friendly Configurable Trigger, scaler and delay Module for nuclear and particle physics

A configurable trigger scaler and delay NIM module has been designed to equip nuclear physics experiments and lab teaching classes. It is configurable through a Graphical User Interface (GUI) and provides a large number of possible trigger conditions without any Hardware Description Language (HDL) required knowledge. The design, performances and typical applications are presented.

preprint2010arXiv

Data acquisition electronics and reconstruction software for directional detection of Dark Matter with MIMAC

Directional detection of galactic Dark Matter requires 3D reconstruction of low energy nuclear recoils tracks. A dedicated acquisition electronics with auto triggering feature and a real time track reconstruction software have been developed within the framework of the MIMAC project of detector. This auto-triggered acquisition electronic uses embedded processing to reduce data transfer to its useful part only, i.e. decoded coordinates of hit tracks and corresponding energy measurements. An acquisition software with on-line monitoring and 3D track reconstruction is also presented.

preprint2010arXiv

Development of a front end ASIC for Dark Matter directional detection with MIMAC

A front end ASIC (BiCMOS-SiGe 0.35 \mum) has been developed within the framework of the MIMAC detector project, which aims at directional detection of non-baryonic Dark Matter. This search strategy requires 3D reconstruction of low energy (a few keV) tracks with a gaseous \muTPC. The development of this front end ASIC is a key point of the project, allowing the 3D track reconstruction. Each ASIC monitors 16 strips of pixels with charge preamplifiers and their time over threshold is provided in real time by current discriminators via two serializing LVDS links working at 320 MHz. The charge is summed over the 16 strips and provided via a shaper. These specifications have been chosen in order to build an auto triggered electronics. An acquisition board and the related software were developed in order to validate this methodology on a prototype chamber. The prototype detector presents an anode where 2 x 96 strips of pixels are monitored.

preprint2010arXiv

Directional detection of non-baryonic dark matter with MIMAC

Directional detection of non-baryonic Dark Matter is a promising search strategy for discriminating genuine WIMP events from background ones. However, carrying out such a strategy requires both a precise measurement of the energy down to a few keV and 3D reconstruction of tracks down to a few mm. To achieve this goal, the MIMAC project has been developed: it is based on a gaseous micro-TPC matrix, filled with 3He, CF4 and/or C4H10. Firsts results of low energy nuclei recoils obtained with a low energy neutron field are presented.

preprint2010arXiv

Level-1 jet trigger hardware for the ALICE electromagnetic calorimeter at LHC

The ALICE experiment at the LHC is equipped with an electromagnetic calorimeter (EMCal) designed to enhance its capabilities for jet measurement. In addition, the EMCal enables triggering on high energy jets. Based on the previous development made for the Photon Spectrometer (PHOS) level-0 trigger, a specific electronic upgrade was designed in order to allow fast triggering on high energy jets (level-1). This development was made possible by using the latest generation of FPGAs which can deal with the instantaneous incoming data rate of 26 Gbit/s and process it in less than 4 μs.

preprint2010arXiv

MIMAC : A micro-tpc matrix for directional detection of dark matter

Directional detection of non-baryonic Dark Matter is a promising search strategy for discriminating WIMP events from background. However, this strategy requires both a precise measurement of the energy down to a few keV and 3D reconstruction of tracks down to a few mm. To achieve this goal, the MIMAC project has been developed. It is based on a gaseous micro-TPC matrix, filled with 3He, CF4 and/or C4H10. The first results on low energy nuclear recoils (1H and 19F) obtained with a low mono-energetic neutron field are presented. The discovery potential of this search strategy is discussed and illustrated by a realistic case accessible to MIMAC.

preprint2009arXiv

A prototype of a directional detector for non-baryonic dark matter search: MIMAC (Micro-TPC Matrix of Chambers)

We have developed a micro-tpc using a pixelized bulk micromegas coupled to dedicated acquisition electronics as a read-out allowing to reconstruct the three dimensional track of a few keV recoils. The prototype has been tested with the Amande facility at the IRSN-Cadarache providing monochromatic neutrons. The first results concerning discrimination of a few keV electrons and proton recoils are presented.