Source author record

D. Hallman

D. Hallman appears in the imported research catalog. Authorship, coauthor and topic links are available while profile ownership is still unclaimed.

ResearcherUnclaimed source record

Catalog footprint

What is connected

9works
4topics
4close collaborators

Actions

Connect this record

Log in to claim

Research graph

See the researcher in context

Open full explorer

Inspect adjacent papers, topics, institutions and collaborators without losing the researcher page.

Building this map preview

BZPEER is loading the nearby papers, people, topics and institutions for this page.

Published work

9 published item(s)

preprint2025arXiv

First Evidence of Solar Neutrino Interactions on $^{13}$C

The SNO+ Collaboration reports the first evidence of $^{8}\text{B}$ solar neutrinos interacting on $^{13}\text{C}$ nuclei. The charged current interaction proceeds through $^{13}\text{C} + ν_e \rightarrow {}^{13}\text{N} + e^-$ which is followed, with a 10 minute half-life, by ${}^{13}\text{N} \rightarrow {}^{13}\text{C} + e^+ +ν_e .$ The detection strategy is based on the delayed coincidence between the electron and the positron. Evidence for the charged current signal is presented with a significance of 4.2$σ$. Using the natural abundance of $^{13}\text{C}$ present in the scintillator, 5.7 tonnes of $^{13}\text{C}$ over 231 days of data were used in this analysis. The 5.6$^{+3.0}_{-2.3}$ observed events in the data set are consistent with the expectation of 4.7$^{+0.6}_{-1.3}$ events. This result is the second real-time measurement of CC interactions of $^{8}\text{B}$ neutrinos with nuclei and constitutes the lowest energy observation of neutrino interactions on $^{13}\text{C}$ generally. This enables the first direct measurement of the CC $ν_e$ reaction to the ground state of ${}^{13}\text{N}$, yielding an average cross section of $(16.1 ^{+8.5}_{-6.7} (\text{stat.}) ^{+1.6}_{-2.7} (\text{syst.}) )\times 10^{-43}$ cm$^{2}$ over the relevant $^{8}\text{B}$ solar neutrino energies.

preprint2022arXiv

Improved search for invisible modes of nucleon decay in water with the SNO+ detector

This paper reports results from a search for single and multi-nucleon disappearance from the $^{16}$O nucleus in water within the \snoplus{} detector using all of the available data. These so-called "invisible" decays do not directly deposit energy within the detector but are instead detected through their subsequent nuclear de-excitation and gamma-ray emission. New limits are given for the partial lifetimes: $τ(n\rightarrow inv) > 9.0\times10^{29}$ years, $τ(p\rightarrow inv) > 9.6\times10^{29}$ years, $τ(nn\rightarrow inv) > 1.5\times10^{28}$ years, $τ(np\rightarrow inv) > 6.0\times10^{28}$ years, and $τ(pp\rightarrow inv) > 1.1\times10^{29}$ years at 90\% Bayesian credibility level (with a prior uniform in rate). All but the ($nn\rightarrow inv$) results improve on existing limits by a factor of about 3.

preprint2020arXiv

Measurement of neutron-proton capture in the SNO+ water phase

The SNO+ experiment collected data as a low-threshold water Cherenkov detector from September 2017 to July 2019. Measurements of the 2.2-MeV $γ$ produced by neutron capture on hydrogen have been made using an Am-Be calibration source, for which a large fraction of emitted neutrons are produced simultaneously with a 4.4-MeV $γ$. Analysis of the delayed coincidence between the 4.4-MeV $γ$ and the 2.2-MeV capture $γ$ revealed a neutron detection efficiency that is centered around 50% and varies at the level of 1% across the inner region of the detector, which to our knowledge is the highest efficiency achieved among pure water Cherenkov detectors. In addition, the neutron capture time constant was measured and converted to a thermal neutron-proton capture cross section of $336.3^{+1.2}_{-1.5}$ mb.

preprint2016arXiv

Current Status and Future Prospects of the SNO+ Experiment

SNO+ is a large liquid scintillator-based experiment located 2km underground at SNOLAB, Sudbury, Canada. It reuses the Sudbury Neutrino Observatory detector, consisting of a 12m diameter acrylic vessel which will be filled with about 780 tonnes of ultra-pure liquid scintillator. Designed as a multipurpose neutrino experiment, the primary goal of SNO+ is a search for the neutrinoless double-beta decay (0$νββ$) of 130Te. In Phase I, the detector will be loaded with 0.3% natural tellurium, corresponding to nearly 800 kg of 130Te, with an expected effective Majorana neutrino mass sensitivity in the region of 55-133 meV, just above the inverted mass hierarchy. Recently, the possibility of deploying up to ten times more natural tellurium has been investigated, which would enable SNO+ to achieve sensitivity deep into the parameter space for the inverted neutrino mass hierarchy in the future. Additionally, SNO+ aims to measure reactor antineutrino oscillations, low-energy solar neutrinos, and geoneutrinos, to be sensitive to supernova neutrinos, and to search for exotic physics. A first phase with the detector filled with water will begin soon, with the scintillator phase expected to start after a few months of water data taking. The 0$νββ$ Phase I is foreseen for 2017.

preprint2011arXiv

A magnetically-driven piston pump for ultra-clean applications

A magnetically driven piston pump for xenon gas recirculation is presented. The pump is designed to satisfy extreme purity and containment requirements, as is appropriate for the recirculation of isotopically enriched xenon through the purification system and large liquid xenon TPC of EXO-200. The pump, using sprung polymer gaskets, is capable of pumping more than 16 standard liters per minute (SLPM) of xenon gas with 750 torr differential pressure.

preprint2011arXiv

A xenon gas purity monitor for EXO

We discuss the design, operation, and calibration of two versions of a xenon gas purity monitor (GPM) developed for the EXO double beta decay program. The devices are sensitive to concentrations of oxygen well below 1 ppb at an ambient gas pressure of one atmosphere or more. The theory of operation of the GPM is discussed along with the interactions of oxygen and other impurities with the GPM's tungsten filament. Lab tests and experiences in commissioning the EXO-200 double beta decay experiment are described. These devices can also be used on other noble gases.

preprint2011arXiv

Xenon purity analysis for EXO-200 via mass spectrometry

We describe purity measurements of the natural and enriched xenon stockpiles used by the EXO-200 double beta decay experiment based on a mass spectrometry technique. The sensitivity of the spectrometer is enhanced by several orders of magnitude by the presence of a liquid nitrogen cold trap, and many impurity species of interest can be detected at the level of one part-per-billion or better. We have used the technique to screen the EXO-200 xenon before, during, and after its use in our detector, and these measurements have proven useful. This is the first application of the cold trap mass spectrometry technique to an operating physics experiment.

preprint2010arXiv

A simple radionuclide-driven single-ion source

We describe a source capable of producing single barium ions through nuclear recoils in radioactive decay. The source is fabricated by electroplating 148Gd onto a silicon α-particle detector and vapor depositing a layer of BaF2 over it. 144Sm recoils from the alpha decay of 148Gd are used to dislodge Ba+ ions from the BaF2 layer and emit them in the surrounding environment. The simultaneous detection of an α particle in the substrate detector allows for tagging of the nuclear decay and of the Ba+ emission. The source is simple, durable, and can be manipulated and used in different environments. We discuss the fabrication process, which can be easily adapted to emit most other chemical species, and the performance of the source.

preprint2009arXiv

Characterization of large area APDs for the EXO-200 detector

EXO-200 uses 468 large area avalanche photodiodes (LAAPDs) for detection of scintillation light in an ultra-low-background liquid xenon (LXe) detector. We describe initial measurements of dark noise, gain and response to xenon scintillation light of LAAPDs at temperatures from room temperature to 169K - the temperature of liquid xenon. We also describe the individual characterization of more than 800 LAAPDs for selective installation in the EXO-200 detector.