Researcher profile

D. Habs

D. Habs contributes to research discovery and scholarly infrastructure.

ResearcherAffiliation not importedOpen to collaborate

Trust snapshot

Quick read

Trust 21 - EmergingVerification L1Unclaimed author
6works
0followers
5topics
4close collaborators

Actions

Decide how to stay connected

Follow researcher0

Identity and collaboration

How to connect with this researcher

Claiming links this public author record to a researcher profile and unlocks direct collaboration workflows.

Log in to claim

Direct collaboration

Open a focused conversation when the fit is right

Claim this author entity first to unlock direct invitations.

Research graph

See the researcher in context

Open full explorer

Inspect adjacent work, topics, institutions and collaborators without jumping out to a separate graph page.

Building this graph slice

BZPEER is loading the nearby papers, people, topics and institutions for this page.

Published work

6 published item(s)

preprint2014arXiv

Scaling of laser-driven ion energies in the relativistic transparent regime

Laser-driven ions have compelling properties and their potential use for medical applications has attracted a huge global interest. One of the major challenges of these applications is generating beams of the required energies. To date, there has been no systematic study of the effect of laser intensity on the generation of laser-driven ions from ultrathin foils during relativistic transparency. Here we present a scaling for ion energies with respect to the on-target laser intensity and in considering target thickness we find an optimum thickness closely related to the experimentally observed relativistic transparency. A steep linear scaling with the normalized laser amplitude a0 has been measured and verified with PIC simulations. In contrast to TNSA, this scaling is much steeper and has been measured for ions with Z > 1. Following our results, ion energies exceeding 100MeV/amu are already accessible with currently available laser systems enabling realization of numerous advanced applications

preprint2014arXiv

Sub-millimeter nuclear medical imaging with high sensitivity in positron emission tomography using beta-gamma coincidences

We present a nuclear medical imaging technique, employing triple-gamma trajectory intersections from beta^+ - gamma coincidences, able to reach sub-millimeter spatial resolution in 3 dimensions with a reduced requirement of reconstructed intersections per voxel compared to a conventional PET reconstruction analysis. This '$γ$-PET' technique draws on specific beta^+ - decaying isotopes, simultaneously emitting an additional photon. Exploiting the triple coincidence between the positron annihilation and the third photon, it is possible to separate the reconstructed 'true' events from background. In order to characterize this technique, Monte-Carlo simulations and image reconstructions have been performed. The achievable spatial resolution has been found to reach ca. 0.4 mm (FWHM) in each direction for the visualization of a 22Na point source. Only 40 intersections are sufficient for a reliable sub-millimeter image reconstruction of a point source embedded in a scattering volume of water inside a voxel volume of about 1 mm^3 ('high-resolution mode'). Moreover, starting with an injected activity of 400 MBq for ^76Br, the same number of only about 40 reconstructed intersections are needed in case of a larger voxel volume of 2 x 2 x 3~mm^3 ('high-sensitivity mode'). Requiring such a low number of reconstructed events significantly reduces the required acquisition time for image reconstruction (in the above case to about 140 s) and thus may open up the perspective for a quasi real-time imaging.

preprint2012arXiv

A Quantal, Partially Ordered Electron Structure as a Basis for a γFree Electron Laser (γ-FEL)

When a rather cold electron bunch is transported during laser bubble acceleration in a strongly focusing plasma channel with typical forces of 100 GeV/m, it will form partially ordered long electron cylinders due to the relativistically longitudinal reduced repulsion between electrons, resulting in a long-range pair correlation function, when reaching energies in the laboratory above 0.5 GeV. During Compton back-scattering with a second laser, injected opposite to the electron bunch, the electron bunch will be further modulated with micro bunches and due to its ordered structure will reflect coherently, Mössbauer-like, resulting in a γfree electron laser (γ-FEL). Increasing the relativistic γfactor, the quantal regime becomes more dominant. We discuss the scaling laws with γ.

preprint2012arXiv

Medical Application Studies at ELI-NP

We study the production of radioisotopes for nuclear medicine in (gamma,gamma') photoexcitation reactions or (gamma,xn + yp) photonuclear reactions for the examples of ^195mPt, ^117mSn and ^44Ti with high flux [(10^13 - 10^15) gamma/s], small beam diameter and small energy band width (Delta E/E ~ 10^-3 -10^-4) gamma beams. In order to realize an optimum gamma-focal spot, a refractive gamma-lens consisting of a stack of many concave micro-lenses will be used. It allows for the production of a high specific activity and the use of enriched isotopes. For photonuclear reactions with a narrow gamma beam, the energy deposition in the target can be reduced by using a stack of thin target wires, hence avoiding direct stopping of the Compton electrons and e^+e^- pairs. The well-defined initial excitation energy of the compound nucleus leads to a small number of reaction channels and enables new combinations of target isotope and final radioisotope. The narrow-bandwidth gamma excitation may make use of collective resonances in gamma-width, leading to increased cross sections. (gamma,gamma') isomer production via specially selected gamma cascades allows to produce high specific activity in multiple excitations, where no back-pumping of the isomer to the ground state occurs. The produced isotopes will open the way for completely new clinical applications of radioisotopes. For example ^195mPt could be used to verify the patient's response to chemotherapy with platinum compounds before a complete treatment is performed. In targeted radionuclide therapy the short-range Auger and conversion electrons of ^195mPt and ^117mSn enable a very local treatment. The generator ^44Ti allows for a PET with an additional gamma-quantum (gamma-PET), resulting in a reduced dose or better spatial resolution.

preprint2012arXiv

Submillimeter nuclear medical imaging with a Compton Camera using triple coincidences of collinear β+ annihilation photons and γ-rays

Modern PET systems reach a spatial resolution of 3-10 mm. A disadvantage of this technique is the diffusion of the positron before its decay with a typical range of ca. 1 mm (depending on its energy). This motion and Compton scattering of the 511 keV photons within the patient limit the performance of PET. We present a nuclear medical imaging technique, able to reach submillimeter spatial resolution in 3 dimensions with a reduced activity application compared to conventional PET. This 'gamma-PET' technique draws on specific positron sources simultaneously emitting an additional photon with the β+ decay. Exploiting the triple coincidence between the positron annihilation and the third photon, it is possible to separate the reconstructed 'true' events from background. In order to test the feasibility of this technique, Monte-Carlo simulations and image reconstruction has been performed. The spatial resolution amounts to 0.2 mm (FWHM) in each direction, surpassing the performance of conventional PET by about an order of magnitude. The simulated detector geometry exhibits a coincidence detection efficiency of 1.92e-7 per decay. Starting with only 0.7 MBq of source activity (ca. 200-500 times less compared to conventional PET) an exposure time of 450 s is sufficient for source reconstruction.

preprint2010arXiv

Dynamics of Nanometer-Scale Foil Targets Irradiated with Relativistically Intense Laser Pulses

In this letter we report on an experimental study of high harmonic radiation generated in nanometer-scale foil targets irradiated under normal incidence. The experiments constitute the first unambiguous observation of odd-numbered relativistic harmonics generated by the $\vec{v}\times\vec{B}$ component of the Lorentz force verifying a long predicted property of solid target harmonics. Simultaneously the observed harmonic spectra allow in-situ extraction of the target density in an experimental scenario which is of utmost interest for applications such as ion acceleration by the radiation pressure of an ultraintense laser.