Source author record

D. Fields

D. Fields appears in the imported research catalog. Authorship, coauthor and topic links are available while profile ownership is still unclaimed.

ResearcherUnclaimed source record

Catalog footprint

What is connected

7works
5topics
4close collaborators

Actions

Connect this record

Log in to claim

Research graph

See the researcher in context

Open full explorer

Inspect adjacent papers, topics, institutions and collaborators without losing the researcher page.

Building this map preview

BZPEER is loading the nearby papers, people, topics and institutions for this page.

Published work

7 published item(s)

preprint2022arXiv

First Dark Matter Search Results From Coherent CAPTAIN-Mills

This paper describes the operation of the Coherent CAPTAIN-Mills (CCM) detector located at the Lujan Neutron Science Center (LANSCE) at Los Alamos National Laboratory (LANL). CCM is a 10-ton liquid argon (LAr) detector located 20 meters from a high flux neutron/neutrino source and is designed to search for sterile neutrinos ($ν_s$) and light dark matter (LDM). An engineering run was performed in Fall 2019 to study the characteristics of the CCM120 detector by searching for coherent scattering signals consistent with $ν_s$'s and LDM resulting from $π^+$ and $π^0$ decays in the tungsten target. New parameter space in a leptophobic dark matter model was excluded for DM masses between $\sim2.0$ and 30 MeV. The lessons learned from this run have guided the development and construction of the new CCM200 detector that will begin operations in 2021 and significantly improve on these searches.

preprint2022arXiv

First Leptophobic Dark Matter Search from Coherent CAPTAIN-Mills

We report the first results of a search for leptophobic dark matter (DM) from the Coherent CAPTAIN-Mills (CCM) liquid argon (LAr) detector. An engineering run with 120 photomultiplier tubes (PMTs) and $17.9 \times 10^{20}$ protons-on-target (POT) was performed in Fall 2019 to study the characteristics of the CCM detector. The operation of this 10-ton detector was strictly light-based with a threshold of 50 keV and used coherent elastic scattering off argon nuclei to detect DM. Despite only 1.5 months of accumulated luminosity, contaminated LAr, and non-optimized shielding, CCM's first engineering run already achieved sensitivity to previously unexplored parameter space of light dark matter (LDM) models with a baryonic vector portal. With an expected background of 115,005 events, we observe 115,005+16.5 events which is compatible with background expectations. For a benchmark mediator-to-dark matter mass ratio of $m_{_{V_B}}/m_χ=2.1$, DM masses within the range $9\,\text{MeV} \lesssim m_χ\lesssim 50\,\text{MeV}$ have been excluded at 90% C.L. in the leptophobic model after applying the Feldman-Cousins test statistic. CCM's upgraded run with 200 PMTs, filtered LAr, improved shielding, and ten times more POT will be able to exclude the remaining thermal relic density parameter space of this model, as well as probe new parameter space of other leptophobic DM models.

preprint2020arXiv

AI-optimized detector design for the future Electron-Ion Collider: the dual-radiator RICH case

Advanced detector R&D requires performing computationally intensive and detailed simulations as part of the detector-design optimization process. We propose a general approach to this process based on Bayesian optimization and machine learning that encodes detector requirements. As a case study, we focus on the design of the dual-radiator Ring Imaging Cherenkov (dRICH) detector under development as part of the particle-identification system at the future Electron-Ion Collider (EIC). The EIC is a US-led frontier accelerator project for nuclear physics, which has been proposed to further explore the structure and interactions of nuclear matter at the scale of sea quarks and gluons. We show that the detector design obtained with our automated and highly parallelized framework outperforms the baseline dRICH design within the assumptions of the current model. Our approach can be applied to any detector R&D, provided that realistic simulations are available.

preprint2014arXiv

The PHENIX Forward Silicon Vertex Detector

A new silicon detector has been developed to provide the PHENIX experiment with precise charged particle tracking at forward and backward rapidity. The Forward Silicon Vertex Tracker (FVTX) was installed in PHENIX prior to the 2012 run period of the Relativistic Heavy Ion Collider (RHIC). The FVTX is composed of two annular endcaps, each with four stations of silicon mini-strip sensors, covering a rapidity range of $1.2<|η|<2.2$ that closely matches the two existing PHENIX muon arms. Each station consists of 48 individual silicon sensors, each of which contains two columns of mini-strips with 75 $μ$m pitch in the radial direction and lengths in the $ϕ$ direction varying from 3.4 mm at the inner radius to 11.5 mm at the outer radius. The FVTX has approximately 0.54 million strips in each endcap. These are read out with FPHX chips, developed in collaboration with Fermilab, which are wire bonded directly to the mini-strips. The maximum strip occupancy reached in central Au-Au collisions is approximately 2.8%. The precision tracking provided by this device makes the identification of muons from secondary vertices away from the primary event vertex possible. The expected distance of closest approach (DCA) resolution of 200 $μ$m or better for particles with a transverse momentum of 5 GeV/$c$ will allow identification of muons from relatively long-lived particles, such as $D$ and $B$ mesons, through their broader DCA distributions.

preprint2010arXiv

XMM-{\em Newton} and FUSE Tentative Evidence for a WHIM filament along the Line of Sight to PKS~0558-504

We present a possible OVIII X-ray absorption line at $z=0.117 \pm 0.001$ which, if confirmed, will be the first one associated with a broad HI Ly$β$ (BLB: FWHM=$160^{+50}_{-30}$ km s$^{-1}$) absorber. The absorber lies along the line of sight to the nearby ($z=0.1372$) Seyfert 1 galaxy PKS~0558-504, consistent with being a WHIM filament. The X-ray absorber is marginally detected in two independent XMM-Newton spectra of PKS~0558-504, a long $\sim 600$ ks Guest-Observer observation and a shorter, $\sim 300$ ks total, calibration observation, with a combined single line statistical significance of 2.8$σ$ (2.7$σ$ and 1.2$σ$ in the two spectra, respectively). When fitted with our self-consistent hybrid-photoionization WHIM models, the combined XMM-{\em Newton} spectrum is consistent with the presence of OVIII K$α$ at $z=(0.117 \pm 0.001)$. This model gives best fitting temperature and equivalent H column density of the absorber of log$T=6.56_{-0.17}^{+0.19}$ K, and logN$_H=(21.5 \pm 0.3) (Z/Z_{0.01\odot})^{-1}$ cm$^{-2}$. The statistical sigificance of this single X-ray detection is increased by the detection of broad and complex HI Ly$β$ absorption in archival FUSE spectra of PKS~0558-504, at redshifts $z=0.1183 \pm 0.0001$ consistent with the best-fitting redshift of the X-ray absorber. The single line statistical significance of this line is 4.1$σ$ (3.7$σ$ if systematics are considered), and thus the combined (HI+OVIII) statistical significance of the detection is of 5.0$σ$. The detection of both metal and H lines at a consistent redshift, in this hot absorbing system, allows us to speculate on its metallicity. By associating the bulk of the X-ray absorber with the BLB line detected in the FUSE spectrum at $z_{BLB}=0.1183 \pm 0.0001$, we obtain a metallicity of 1-4\% Solar.

preprint2009arXiv

XMM-Newton observations of SDSS J143030.22$-$001115.1: an unusually flat spectrum AGN

We present XMM observations of the AGN SDSS 1430-0011. The low S/N spectrum of this source obtained in a snap shot Chandra observation showed an unusually flat continuum. With the follow up XMM observations we find that the source spectrum is complex; it either has an ionized absorber or a partially covering absorber. The underlying power-law is in the normal range observed for AGNs. The low luminosity of the source during Chandra observations can be understood in terms of variations in the absorber properties. The X-ray and optical properties of this source are such that it cannot be securely classified as either a narrow line Seyfert 1 or a broad line Seyfert 1 galaxy.

preprint2002arXiv

Measurement of Spin Transfer Observables in Antiproton-Proton -> Antilambda-Lambda at 1.637 GeV/c

Spin transfer observables for the strangeness-production reaction Antiproton-Proton -> Antilambda-Lambda have been measured by the PS185 collaboration using a transversely-polarized frozen-spin target with an antiproton beam momentum of 1.637 GeV/c at the Low Energy Antiproton Ring at CERN. This measurement investigates observables for which current models of the reaction near threshold make significantly differing predictions. Those models are in good agreement with existing measurements performed with unpolarized particles in the initial state. Theoretical attention has focused on the fact that these models produce conflicting predictions for the spin-transfer observables D_{nn} and K_{nn}, which are measurable only with polarized target or beam. Results presented here for D_{nn} and K_{nn} are found to be in disagreement with predictions from existing models. These results also underscore the importance of singlet-state production at backward angles, while current models predict complete or near-complete triplet-state dominance.