Researcher profile

D. A. Tekueva

D. A. Tekueva contributes to research discovery and scholarly infrastructure.

ResearcherAffiliation not importedOpen to collaborate

Trust snapshot

Quick read

Trust 21 - Emerging
8works
0followers
4topics
4close collaborators

Actions

Decide how to stay connected

Follow researcher0

Research graph

See the researcher in context

Open full explorer

Inspect adjacent work, topics, institutions and collaborators without jumping out to a separate graph page.

Building this graph slice

BZPEER is loading the nearby papers, people, topics and institutions for this page.

Published work

8 published item(s)

preprint2018arXiv

The background simulation of experiment for searching of $2\nu2K$ capture in Xe-124

We describe the Monte Carlo (MC) simulation package of the `2K-CAPTURE' setup and discuss the agreement of its output with data. The `2K-CAPTURE' MC simulates the energy loss of particles in detector and components of the passive shield and generates the resulting response in working volume large proportional counter (LPC). The simulation accounts for absorption, reemission, and scattering of both photons and neutrons and tracks them until they either are absorbed. The algorithm proceeds with a detailed simulation of the electronics chain. The MC is tuned using data collected with radioactive calibration source deployed in the internal channel of the installation. The simulation reproduces the energy response of the detector corresponding to distribution of the generated pointwise clusters of a charge of primary ionization in LPC.

preprint2015arXiv

High-resolution ion pulse ionization chamber with air filling for the Rn-222 decays detection

The construction and characteristics of the cylindrical ion pulse ionization chamber (CIPIC) with a working volume of 3.2 L are described. The chamber is intended to register alpha-particles from the $^{222}$Rn and its daughter's decays in the filled air sample. The detector is less sensitive to electromagnetic pick-ups and mechanical noises. The digital pulse processing method is proposed to improve the energy resolution of the ion pulse ionization chamber. An energy resolution of 1.6% has been achieved for the 5.49 MeV alpha-line. The dependence of the energy resolution on high voltage and working media pressure has been investigated and the results are presented.

preprint2015arXiv

New limit on the mass of 9.4-keV solar axions emitted in an M1 transition in $^{83}$Kr nuclei

A search for resonant absorption of the solar axion by $^{83}\rm{Kr}$ nuclei was performed using the proportional counter installed inside the low-background setup at the Baksan Neutrino Observatory. The obtained model independent upper limit on the combination of isoscalar and isovector axion-nucleon couplings $|g_3-g_0|\leq 1.69\times 10^{-6}$ allowed us to set the new upper limit on the hadronic axion mass of $m_{A}\leq 130$ eV (95\% C.L.) with the generally accepted values $S$=0.5 and $z$=0.56.

preprint2015arXiv

The origin of the background radioactive isotope Xe-127 in the sample of Xe enriched in Xe-124

The results of investigation of Xe-127 radioactive isotope production in the xenon sample enriched in Xe-124, Xe-126, Xe-128 are presented. The isotope is supposed to be the source of the background events in the low-background experiment on search for 2K-capture of Xe-124. In this work we consider two channels of Xe-127 production: the neutron knock-out from Xe-128 nucleus by cosmogenic muons and the neutron capture by Xe-126 nucleus. For the first channel the upper limit of the cross section of Xe-127 production was found to be sigma >= 0.007 barn at 95\% C.L. For the second channel the value obtained for the cross section was found to be equal to sigma =(2.74+-0.4) barn, which coincides well, within the statistical error, with reference value.

preprint2015arXiv

The study of the thermal neutron flux in the deep underground laboratory DULB-4900

We report on the study of thermal neutron flux using monitors based on mixture of ZnS(Ag) and LiF enriched with a lithium-6 isotope at the deep underground laboratory DULB-4900 at the Baksan Neutrino Observatory. An annual modulation of thermal neutron flux in DULB-4900 is observed. Experimental evidences were obtained of correlation between the long-term thermal neutron flux variations and the absolute humidity of the air in laboratory. The amplitude of the modulation exceed 5\% of total neutron flux.

preprint2014arXiv

First result of the experimental search for the 2K-capture of Xe-124 with the copper proportional counter

First result of experiment for searching of 2K-capture of Xe-124 with the large-volume copper proportional counter is given. The 12 litre sample with 63.3% (44 g) of Xe-124 was used in measurements. The limit on the half-life of Xe-124 with regard to 2K(2ν)-capture for the ground state of Te-124 has been found: T_{1/2} > 4.67x10^{20} y (90% C.L.). A sample with volume 52 L comprising of Xe-124 (10.6 L - 58.6 g) and Xe-126 (14.1 L - 79.3 g) will used at the next step of the experiment to increase a sensitivity of 2K-caption of Xe-124 registration. In this case sensitivity to the investigated process will be at the level of S=1.46 x 10^{21} y (90% C.L.) for 1 year measurement.

preprint2014arXiv

First result of the experimental search for the 9.4 keV solar axion reactions with Kr-83 in the copper proportional counter

The experimental search for solar hadronic axions is started at the Baksan Neutrino Observatory of the Institute for Nuclear Researches Russian Academy of Science. It is assumed that axions are created in the Sun during M1-transition between the first thermally excited level at 9.4 keV and the ground state in Kr-83. The experiment is based on axion detection via resonant absorption process by the same nucleus in the detector. The big copper proportional counter filled with krypton is used to detect signals from axions. The experimental setup is situated in the deep underground low background laboratory. No evidence of axion detection were found after the 26.5 days data collection. Resulting new upper limit on axion mass is m_{A} < 130 eV at 95% C.L.