Source author record

Curt A. Richter

Curt A. Richter appears in the imported research catalog. Authorship, coauthor and topic links are available while profile ownership is still unclaimed.

ResearcherUnclaimed source record

Catalog footprint

What is connected

7works
5topics
4close collaborators

Actions

Connect this record

Log in to claim

Research graph

See the researcher in context

Open full explorer

Inspect adjacent papers, topics, institutions and collaborators without losing the researcher page.

Building this map preview

BZPEER is loading the nearby papers, people, topics and institutions for this page.

Published work

7 published item(s)

preprint2022arXiv

How to Report and Benchmark Emerging Field-Effect Transistors

Emerging low-dimensional nanomaterials have been studied for decades in device applications as field-effect transistors (FETs). However, properly reporting and comparing device performance has been challenging due to the involvement and interlinking of multiple device parameters. More importantly, the interdisciplinarity of this research community results in a lack of consistent reporting and benchmarking guidelines. Here we report a consensus among the authors regarding guidelines for reporting and benchmarking important FET parameters and performance metrics. We provide an example of this reporting and benchmarking process for a two-dimensional (2D) semiconductor FET. Our consensus will help promote an improved approach for assessing device performance in emerging FETs, thus aiding the field to progress more consistently and meaningfully.

preprint2021arXiv

Geometric interference in a high-mobility graphene annulus p-n junction device

The emergence of interference is observed in the resistance of a graphene annulus pn junction device as a result of applying two separate gate voltages. The observed resistance patterns are carefully inspected, and it is determined that the position of the peaks resulting from those patterns are independent of temperature and magnetic field. Furthermore, these patterns are not attributable to Aharonov-Bohm oscillations, Fabry Perot interference at the junction, or moiré potentials. The device data are compared with those of another device fabricated with a traditional Hall bar geometry, as well as with quantum transport simulation data. Since the two devices are of different topological classes, the subtle differences observed in the corresponding measured data indicate that the most likely source of the observed geometric interference patterns is quantum scarring.

preprint2019arXiv

Rapid, Quantitative Therapeutic Screening for Alzheimer's Enzymes Enabled by Optimal Signal Transduction with Transistors

We show that simple, commercially sourced n-channel silicon field-effect transistors (nFETs) operating under closed loop control exhibit an ~3-fold improvement in pH readout resolution to (7.2+/-0.3)x10^-3 at a bandwidth of 10 Hz when compared with the open loop operation commonly employed by integrated ion-sensitive field-effect transistors (ISFETs). We leveraged the improved nFET performance to measure the change in solution pH arising from the activity of a pathological form of the kinase Cdk5, an enzyme implicated in Alzheimer's disease, and showed quantitative agreement with previous measurements. The improved pH resolution was realized while the devices were operated in a remote sensing configuration with the pH sensing element off-chip and connected electrically to the FET gate terminal. We compared these results with those measured by using a custom-built dual-gate 2D field-effect transistor (dg2DFET) fabricated with 2D semi-conducting MoS2 channels and a moderate device gain, alpha=8. Under identical solution conditions the pH resolution of the nFETs was only 2-fold worse than the dg2DFETs pH resolution of (3.9+/-0.7)x10^-3. Finally, using the nFETs, we demonstrated the effectiveness of a custom polypeptide, p5, as a therapeutic agent in restoring the function of Cdk5. We expect that the straight-forward modifications to commercially sourced nFETs demonstrated here will lower the barrier to widespread adoption of these remote-gate devices and enable sensitive bioanalytical measurements for high throughput screening in drug discovery and precision medicine applications.

preprint2014arXiv

Broad Band Optical Properties of Large Area Monolayer CVD Molybdenum Disulfide

Recently emerging large-area single-layer MoS2 grown by chemical vapor deposition has triggered great interest due to its exciting potential for applications in advanced electronic and optoelectronic devices. Unlike gapless graphene, MoS2 has an intrinsic band gap in the visible which crosses over from an indirect to a direct gap when reduced to a single atomic layer. In this article, we report a comprehensive study of fundamental optical properties of MoS2 revealed by optical spectroscopy of Raman, photoluminescence, and vacuum ultraviolet spectroscopic ellipsometry. A band gap of 1.42 eV is determined by the absorption threshold of bulk MoS2 that shifts to 1.83 eV in monolayer MoS2. We extracted the high precision dielectric function up to 9.0 eV which leads to the identification of many unique interband transitions at high symmetry points in the MoS2 momentum space. The positions of the A and B excitons in single layers are found to shift upwards in energy compared with those of the bulk form and have smaller separation. A very strong optical critical point predicted to correspond to a quasi-particle gap is observed at 2.86 eV, which is attributed to optical transitions along the parallel bands between the M and gama points in the reduced Brillouin zone. The absence of the bulk MoS2 spin-orbit interaction peak at ~ 3.0 eV in monolayer MoS2 is, as predicted, the consequence of the coalescence of nearby excitons. A higher energy optical transition at 3.98 eV, commonly occurred in bulk semiconductors, is associated with a combination of several critical points.These optical transitions herein reported enhance our understanding of monolayer MoS2 as well as of two-dimensional systems in general, and thus provide informative guidelines for MoS2 optical device designs and theoretical considerations.

preprint2014arXiv

Electron and Hole Photoemission Detection for Band Offset Determination of Tunnel Field-Effect Transistor Heterojunctions

The electrical performance of a tunnel field-effect transistor depends critically on the band offset at their semiconductor heterojunction interface. Historically, it has been difficult to experimentally determine how the electronic bands align at the heterojunction interface. We report here on experimental methods to ascertain a complete energy band alignment of a broken-gap tunnel field-effect transistor based on an InAs/GaSb hetero-junction. By using graphene as an optically transparent electrode in a traditional internal photoemission measurement, both the electron and hole barrier heights at the InAs/GaSb interface can be quantified. For a Al2O3/InAs/GaSb layer structure, the barrier height from the top of InAs and GaSb valence band to the bottom of Al2O3 conduction band is inferred from electron emission whereas hole emissions reveal the barrier height from the top of Al2O3 valence band to the bottom of InAs and GaSb conduction band. Subsequently, the offset parameter at the broken gap InAs/GaSb interface is extracted and thus can be used to facilitate the development of predicted model of electron quantum tunneling efficiency and transistor performance.

preprint2013arXiv

Graphene as Transparent Electrode for Direct Observation of Hole Photoemission from Silicon to Oxide

The outstanding electrical and optical properties of graphene make it an excellent alternative as a transparent electrode. Here we demonstrate the application of graphene as collector material in internal photoemission (IPE) spectroscopy; enabling the direct observation of both electron and hole injections at a Si/Al2O3 interface and successfully overcoming the long-standing difficulty of detecting holes injected from a semiconductor emitter in IPE measurements. The observed electron and hole barrier heights are 3.5 eV and 4.1 eV, respectively. Thus the bandgap of Al2O3 can be further deduced to be 6.5 eV, in close agreement with the valued obtained by vacuum ultraviolet spectroscopic ellipsometry analysis. The detailed optical modeling of a graphene/Al2O3/Si stack reveals that by using graphene in IPE measurements the carrier injection from the emitter is significantly enhanced and the contribution of carrier injection from the collector electrode is minimal. The method can be readily extended to various IPE test structures for a complete band alignment analysis and interface characterization.

preprint2013arXiv

Highly reproducible metal/graphene contacts and stable electrical performance by UV-Ozone treatment

Resist residue from the device fabrication process is a general and significant source of the metal/graphene contact interface contamination. In this paper, Ultraviolet-Ozone (UVO) treatment is proven to be an effective way of cleaning the metal/graphene interface. Electrical measurements of devices, which were fabricated by using UVO treatment of the metal/graphene contact region, show that stable and highly reproducible low contact resistance between metal and graphene is obtained without affecting the electrical properties of the graphene channel itself.