Researcher profile

Clayton R. Locke

Clayton R. Locke contributes to research discovery and scholarly infrastructure.

ResearcherAffiliation not importedOpen to collaborate

Trust snapshot

Quick read

Trust 15 - Baseline
3works
0followers
8topics
4close collaborators

Actions

Decide how to stay connected

Follow researcher0

Research graph

See the researcher in context

Open full explorer

Inspect adjacent work, topics, institutions and collaborators without jumping out to a separate graph page.

Building this graph slice

BZPEER is loading the nearby papers, people, topics and institutions for this page.

Published work

3 published item(s)

preprint2014arXiv

Spectroscopy and laser cooling on the $^{1}S_{0}-\,^{3}P_{1}$ line in Yb via an injection-locked diode laser at 1111.6nm

We generate 555.8nm light with sub-MHz linewidth through the use of laser injection-locking of a semiconductor diode at 1111.6nm, followed by frequency doubling in a resonant cavity. The integrity of the injection lock is investigated by studying an offset-beat signal between slave and master lasers, by performing spectroscopy on the $(6s)^{2}$ $^{1}S_{0}-\,(6s6p)$ $^{3}P_{1}$ transition in magneto-optically trapped ytterbium, and by demonstrating additional laser cooling of $^{171}$Yb with the 555.8nm light. For the $^{1}S_{0}-$ $^{3}P_{1}$ spectroscopy, we confirm the linear dependence between ground state linewidth and the intensity of an off-resonant laser, namely, that used to cool Yb atoms in a $^{1}S_{0}-$ $^{1}P_{1}$ magneto-optical trap. Our results demonstrate the suitability of injection locked 1100-1130nm laser diodes as a source for sub-MHz linewidth radiation in the yellow-green spectrum.

preprint2012arXiv

Laser frequency comb techniques for precise astronomical spectroscopy

Precise astronomical spectroscopic analyses routinely assume that individual pixels in charge-coupled devices (CCDs) have uniform sensitivity to photons. Intra-pixel sensitivity (IPS) variations may already cause small systematic errors in, for example, studies of extra-solar planets via stellar radial velocities and cosmological variability in fundamental constants via quasar spectroscopy, but future experiments requiring velocity precisions approaching ~1 cm/s will be more strongly affected. Laser frequency combs have been shown to provide highly precise wavelength calibration for astronomical spectrographs, but here we show that they can also be used to measure IPS variations in astronomical CCDs in situ. We successfully tested a laser frequency comb system on the Ultra-High Resolution Facility spectrograph at the Anglo-Australian Telescope. By modelling the 2-dimensional comb signal recorded in a single CCD exposure, we find that the average IPS deviates by <8 per cent if it is assumed to vary symmetrically about the pixel centre. We also demonstrate that series of comb exposures with absolutely known offsets between them can yield tighter constraints on symmetric IPS variations from ~100 pixels. We discuss measurement of asymmetric IPS variations and absolute wavelength calibration of astronomical spectrographs and CCDs using frequency combs.

preprint2005arXiv

Rotating Resonator-Oscillator Experiments to Test Lorentz Invariance in Electrodynamics

In this work we outline the two most commonly used test theories (RMS and SME) for testing Local Lorentz Invariance (LLI) of the photon. Then we develop the general framework of applying these test theories to resonator experiments with an emphasis on rotating experiments in the laboratory. We compare the inherent sensitivity factors of common experiments and propose some new configurations. Finally we apply the test theories to the rotating cryogenic experiment at the University of Western Australia, which recently set new limits in both the RMS and SME frameworks [hep-ph/0506074].