Source author record

Christopher H. Betters

Christopher H. Betters appears in the imported research catalog. Authorship, coauthor and topic links are available while profile ownership is still unclaimed.

ResearcherUnclaimed source record

Catalog footprint

What is connected

4works
4topics
4close collaborators

Actions

Connect this record

Log in to claim

Research graph

See the researcher in context

Open full explorer

Inspect adjacent papers, topics, institutions and collaborators without losing the researcher page.

Building this map preview

BZPEER is loading the nearby papers, people, topics and institutions for this page.

Published work

4 published item(s)

preprint2020arXiv

A Multi-Core Fibre Photonic Lantern Based Spectrograph for Raman Spectroscopy

We report on the development of a compact (volume $\approx$ 100\:cm$^3$), multimode diffraction-limited Raman spectrograph and probe designed to be compact as possible. The spectrograph uses `off the shelf' optics, a custom 3D-printed two-part housing and harnesses a multi-core fibre (MCF) photonic lantern (multimode to few-mode converter), which slices a large 40~\textmu m multimode input into a near-diffraction-limited 6~\textmu m aperture. Our unique design utilises the hexagonal geometry of our MCF, permitting high multimode collection efficiency with near-diffraction-limited performance in a compact design. Our approach does not require a complex reformatter or mask and thus preserves spectral information and throughput when forming the entrance slit of the spectrograph. We demonstrate the technology over the interval 800~nm to 940~nm (200~cm$^{-1}$ to 2000~cm$^{-1}$) with a resolution of 0.3\:nm (4\:cm$^{-1}$), but other spectral regions and resolutions from the UV to the near infrared are also possible. We demonstrate the performance of our system by recording the Raman spectra of several compounds, including the pharmaceuticals paracetamol and ibuprofen.

preprint2013arXiv

Beating the classical limit: A diffraction-limited spectrograph for an arbitrary input beam

We demonstrate a new approach to classical fiber-fed spectroscopy. Our method is to use a photonic lantern that converts an arbitrary (e.g. incoherent) input beam into N diffraction-limited outputs. For the highest throughput, the number of outputs must be matched to the total number of unpolarized spatial modes on input. This approach has many advantages: (i) after the lantern, the instrument is constructed from 'commercial off the shelf' components; (ii) the instrument is the minimum size and mass configuration at a fixed resolving power and spectral order (~shoebox sized in this case); (iii) the throughput is better than 60% (slit to detector, including detector QE of ~80%); (iv) the scattered light at the detector can be less than 0.1% (total power). Our first implementation operates over 1545-1555 nm (limited by the detector, a 640$\times$512 array with 20$μ$m pitch) with a spectral resolution of 0.055nm (R~30,000) using a 1$\times$7 (1 multi-mode input to 7 single-mode outputs) photonic lantern. This approach is a first step towards a fully integrated, multimode photonic microspectrograph.

preprint2012arXiv

Single mode, extreme precision Doppler spectrographs

The 'holy grail' of exoplanet research today is the detection of an earth-like planet: a rocky planet in the habitable zone around a main-sequence star. Extremely precise Doppler spectroscopy is an indispensable tool to find and characterize earth-like planets; however, to find these planets around solar-type stars, we need nearly one order of magnitude better radial velocity (RV) precision than the best current spectrographs provide. Recent developments in astrophotonics (Bland-Hawthorn & Horton 2006, Bland-Hawthorn et al. 2010) and adaptive optics (AO) enable single mode fiber (SMF) fed, high resolution spectrographs, which can realize the next step in precision. SMF feeds have intrinsic advantages over multimode fiber or slit coupled spectrographs: The intensity distribution at the fiber exit is extremely stable, and as a result the line spread function of a well-designed spectrograph is fully decoupled from input coupling conditions, like guiding or seeing variations (Ihle et al. 2010). Modal noise, a limiting factor in current multimode fiber fed instruments (Baudrand & Walker 2001), can be eliminated by proper design, and the diffraction limited input to the spectrograph allows for very compact instrument designs, which provide excellent optomechanical stability. A SMF is the ideal interface for new, very precise wavelength calibrators, like laser frequency combs (Steinmetz et al. 2008, Osterman et al. 2012), or SMF based Fabry-Perot Etalons (Halverson et al. 2012). At near infrared wavelengths, these technologies are ready to be implemented in on-sky instruments, or already in use. We discuss a novel concept for such a spectrograph.

preprint2012arXiv

The Photonic TIGER: a multicore fiber-fed spectrograph

We present a proof of concept compact diffraction limited high-resolution fiber-fed spectrograph by using a 2D multicore array input. This high resolution spectrograph is fed by a 2D pseudo-slit, the Photonic TIGER, a hexagonal array of near-diffraction limited single-mode cores. We study the feasibility of this new platform related to the core array separation and rotation with respect to the dispersion axis. A 7 core compact Photonic TIGER fiber-fed spectrograph with a resolving power of around R~31000 and 8 nm bandwidth in the IR centered on 1550 nm is demonstrated. We also describe possible architectures based on this concept for building small scale compact diffraction limited Integral Field Spectrographs (IFS).