Source author record

Christophe Daussy

Christophe Daussy appears in the imported research catalog. Authorship, coauthor and topic links are available while profile ownership is still unclaimed.

ResearcherUnclaimed source record

Catalog footprint

What is connected

14works
6topics
4close collaborators

Actions

Connect this record

Log in to claim

Research graph

See the researcher in context

Open full explorer

Inspect adjacent papers, topics, institutions and collaborators without losing the researcher page.

Building this map preview

BZPEER is loading the nearby papers, people, topics and institutions for this page.

Published work

14 published item(s)

preprint2015arXiv

Accurate determination of the Boltzmann constant by Doppler spectroscopy: Towards a new definition of the kelvin

Accurate molecular spectroscopy in the mid-infrared region allows precision measurements of fundamental constants. For instance, measuring the linewidth of an isolated Doppler-broadened absorption line of ammonia around 10 $μ$m enables a determination of the Boltzmann constant k B. We report on our latest measurements. By fitting this lineshape to several models which include Dicke narrowing or speed-dependent collisional effects, we find that a determination of k B with an uncertainty of a few ppm is reachable. This is comparable to the best current uncertainty obtained using acoustic methods and would make a significant contribution to any new value of k B determined by the CODATA. Furthermore, having multiple independent measurements at these accuracies opens the possibility of defining the kelvin by fixing k B, an exciting prospect considering the upcoming redefinition of the International System of Units.

preprint2014arXiv

A widely tunable 10-$μ$m quantum cascade laser phase-locked to a state-of-the-art mid-infrared reference for precision molecular spectroscopy

We report the coherent phase-locking of a quantum cascade laser (QCL) at 10-$μ$m to the secondary frequency standard of this spectral region, a CO2 laser stabilized on a saturated absorption line of OsO4. The stability and accuracy of the standard are transferred to the QCL resulting in a line width of the order of 10 Hz, and leading to our knowledge to the narrowest QCL to date. The locked QCL is then used to perform absorption spectroscopy spanning 6 GHz of NH3 and methyltrioxorhenium, two species of interest for applications in precision measurements.

preprint2014arXiv

Absorption line shape recovery beyond the detection bandwidth limit: application to the precision spectroscopic measurement of the Boltzmann constant

A theoretical model of the influence of detection bandwidth properties on observed line shapes in laser absorption spectroscopy is described. The model predicts artificial frequency shifts, extra broadenings and line asymmetries which must be taken into account in order to obtain accurate central frequencies and other spectroscopic parameters. This reveals sources of systematic effects most probably underestimated so far potentially affecting spectroscopic measurements. This may impact many fields of research, from atmospheric and interstellar physics to precision spectroscopic measurements devoted to metrological applications, tests of quantum electrodynamics or other fundamental laws of nature. Our theoretical model is validated by linear absorption experiments performed on H2O and NH3 molecular lines recorded by precision laser spectroscopy in two distinct spectral regions, near- and mid-infrared. Possible means of recovering original line shape parameters or experimental conditions under which the detection bandwidth has a negligible impact, given a targeted accuracy, are proposed. Particular emphasis is put on the detection bandwidth adjustments required to use such high-quality molecular spectra for a spectroscopic determination of the Boltzmann constant at the 1 ppm level of accuracy.

preprint2014arXiv

Quantum cascade laser frequency stabilisation at the sub-Hz level

Quantum Cascade Lasers (QCL) are increasingly being used to probe the mid-infrared "molecular fingerprint" region. This prompted efforts towards improving their spectral performance, in order to reach ever-higher resolution and precision. Here, we report the stabilisation of a QCL onto an optical frequency comb. We demonstrate a relative stability and accuracy of 2x10-15 and 10-14, respectively. The comb is stabilised to a remote near-infrared ultra-stable laser referenced to frequency primary standards, whose signal is transferred via an optical fibre link. The stability and frequency traceability of our QCL exceed those demonstrated so far by two orders of magnitude. As a demonstration of its capability, we then use it to perform high-resolution molecular spectroscopy. We measure absorption frequencies with an 8x10-13 relative uncertainty. This confirms the potential of this setup for ultra-high precision measurements with molecules, such as our ongoing effort towards testing the parity symmetry by probing chiral species.

preprint2013arXiv

A revised uncertainty budget for measuring the Boltzmann constant using the Doppler Broadening Technique on ammonia

We report on our on-going effort to measure the Boltzmann constant, kB, using the Doppler Broadening Technique. The main systematic effects affecting the measurement are discussed. A revised error budget is presented in which the global uncertainty on systematic effects is reduced to 2.3 ppm. This corresponds to a reduction of more than one order of magnitude compared to our previous Boltzmann constant measurement. Means to reach a determination of kB at the part per million accuracy level are outlined.

preprint2013arXiv

Probing weak force induced parity violation by high resolution mid-infrared molecular spectroscopy

To date no experiment has reached the level of sensitivity required to observe weak nuclear force induced parity violation (PV) energy differences in chiral molecules. In this paper, we present the approach, adopted at Laboratoire de Physique des Lasers (LPL), to measure frequency differences in the vibrational spectrum of enantiomers. We review different spectroscopic methods developed at LPL leading to the highest resolutions, as well as 20 years of CO2 laser stabilization work enabling such precise measurements. After a first attempt to observe PV vibrational frequency shifts using sub-Doppler saturated absorption spectroscopy in a cell, we are currently aiming at an experiment based on Doppler-free two-photon Ramsey interferometry on a supersonic beam. We report on our latest progress towards observing PV with chiral organo-metallic complexes containing a heavy rhenium atom.

preprint2012arXiv

Evidence for speed-dependent effects in NH3 self-broadened spectra: towards a new determination of the Boltzmann constant

In this paper we present an accurate analysis of the shape of an isolated rovibrational ammonia line from the strong nu2 band around 10 $μ$m, recorded by laser absorption spectroscopy. Experimental spectra obtained under controlled temperature and pressure, are confronted to various models that take into account Dicke narrowing or speed-dependent effects. Our results show clear evidence for speed-dependent broadening and shifting, which had never been demonstrated so far in NH3. Accurate lineshape parameters of the nu2 saQ(6,3) line are obtained. Our current project aiming at measuring the Boltzmann constant, kB, by laser spectroscopy will straight away benefit from such knowledge. We anticipate that a first optical determination of kB with a competitive uncertainty of a few ppm is now reachable.

preprint2012arXiv

Progress towards an accurate determination of the Boltzmann constant by Doppler spectroscopy

In this paper, we present significant progress performed on an experiment dedicated to the determination of the Boltzmann constant, k, by accurately measuring the Doppler absorption profile of a line in a gas of ammonia at thermal equilibrium. This optical method based on the first principles of statistical mechanics is an alternative to the acoustical method which has led to the unique determination of k published by the CODATA with a relative accuracy of 1.7 ppm. We report on the first measurement of the Boltzmann constant by laser spectroscopy with a statistical uncertainty below 10 ppm, more specifically 6.4 ppm. This progress results from improvements in the detection method and in the statistical treatment of the data. In addition, we have recorded the hyperfine structure of the probed saQ(6,3) rovibrational line of ammonia by saturation spectroscopy and thus determine very precisely the induced 4.36 (2) ppm broadening of the absorption linewidth. We also show that, in our well chosen experimental conditions, saturation effects have a negligible impact on the linewidth. Finally, we draw the route to future developments for an absolute determination of with an accuracy of a few ppm.

preprint2010arXiv

Progress toward a first observation of parity violation in chiral molecules by high-resolution laser spectroscopy

Parity violation (PV) effects in chiral molecules have so far never been experimentally observed. To take this challenge up, a consortium of physicists, chemists, theoreticians and spectroscopists has been established and aims at measuring PV energy differences between two enantiomers by using high-resolution laser spectroscopy. In this article, we present our common strategy to reach this goal, the progress accomplished in the diverse areas, and point out directions for future PV observations. The work of André Collet on bromochlorofluoromethane enantiomers, their synthesis and their chiral recognition by cryptophanes made feasible the first generation of experiments presented in this paper.

preprint2009arXiv

Determination of the Boltzmann constant by laser spectroscopy as a basis for future measurements of the thermodynamic temperature

In this paper, we present the latest results on the measurement of the Boltzmann constant kB, by laser spectroscopy of ammonia at 10 ?m. The Doppler absorption profile of a ro-vibrational line of an NH3 gas sample at thermal and pressure equilibrium is measured as accurately as possible. The absorption cell is placed inside a large 1m3 thermostat filled with an ice-water mixture, which sets the temperature very close to 273.15 K. Analysing this profile, which is related to the Maxwell-Boltzmann molecular speed distribution, leads to a determination of the Boltzmann constant via a measurement of the Doppler width (proportional tosqrt(kBT)). A spectroscopic determination of the Boltzmann constant with an uncertainty as low as 37 ppm is obtained. Recent improvements with a new passive thermostat lead to a temperature accuracy, stability and homogeneity of the absorption cell better than 1 ppm over a day.

preprint2009arXiv

Measurement of the Boltzmann constant by the Doppler broadening technique at a 3,8x10-5 accuracy level

In this paper, we describe an experiment performed at the Laboratoire de Physique des Lasers and dedicated to an optical measurement of the Boltzmann constant. With the proposed innovative technique, determining comes down to an ordinary frequency measurement. The method consists in measuring as accurately as possible the Doppler absorption profile of a rovibrational line of ammonia in thermal equilibrium. This profile is related to the Maxwell-Boltzmann molecular velocity distribution along the laser beam. A fit of the absorption line shape leads to a determination of the Doppler width proportional to sqrt(kT) and thus to a determination of the Boltzmann constant. The laser source is an ultra-stable CO2 laser with a wavelength . The absorption cell is placed in a thermostat keeping the temperature at 273.15 K within 1.4 mK. We were able to measure with a relative uncertainty as small as 3.8x10-5, which represents an improvement of an order of magnitude for an integration time comparable to our previous measurement published in 2007 [1]

preprint2007arXiv

First direct determination of the Boltzmann constant by an optical method

We have recorded the Doppler profile of a well-isolated rovibrational line in the \nu2 band of 14NH3. Ammonia gas was placed in an absorption cell thermalized by a water-ice bath. By extrapolating to zero pressure, we have deduced the Doppler width which gives a first measurement of the Boltzmann constant, kB, by laser spectroscopy. A relative uncertainty of 2x10-4 has been obtained. The present determination should be significantly improved in the near future and contribute to a new definition of the kelvin.

preprint2005arXiv

Long-distance frequency dissemination with a resolution of 10-17

We use a new technique to disseminate microwave reference signals along ordinary optical fiber. The fractional frequency resolution of a link of 86 km in length is 10-17 for a one day integration time, a resolution higher than the stability of the best microwave or optical clocks. We use the link to compare the microwave reference and a CO2/OsO4 frequency standard that stabilizes a femtosecond laser frequency comb. This demonstrates a resolution of 3.10-14 at 1 s. An upper value of the instability introduced by the femtosecond laser-based synthesizer is estimated as 1.10-14 at 1 s.

preprint2003arXiv

10 um wavefront spatial filtering: first results with chalcogenide fibers

Wavefront cleaning by single-mode fibers has proved to be efficient in optical-infrared interferometry to improve calibration quality. For instance, the FLUOR instrument has demonstrated the capability of fluoride glass single-mode fibers in this respect in the K and L bands. New interferometric instruments developped for the mid-infrared require the same capability for the 8-12 um range. We have initiated a program to develop single-mode fibers in the prospect of the VLTI mid-infrared instrument MIDI and of the ESA/DARWIN and NASA/TPF missions that require excellent wavefront quality. In order to characterize the performances of chalcogenide fibers we are developping, we have set up an experiment to measure the far-field pattern radiated at 10 um. In this paper, we report the first and promising results obtained with this new component.