Source author record

Christoph Reinhardt

Explore this author’s publications, collaborators and research topics. This catalog record has not been claimed by its author.

ResearcherUnclaimed source record

Catalog footprint

Research overview

4works
6topics
4close collaborators

Published work

4 publications

preprint2026arXiv

Design and construction of a cryogenic subcooler-box for supplying single phase supercritical helium to dark matter and gravitational wave experiments

We report on the design, development, and installation of the ALPS Cryo-Platform Subcooler Box (ACPS), which is part of the cryogenic platform being established in the HERA North Hall at DESY to supply helium for cooling large-scale dark-matter and gravitational-wave experiments with very high heat loads. The ACPS is capable of subcooling supercritical helium supplied via the 1.6-km-long HERA transfer line by means of a pipe heat exchanger immersed in a subcooler bath filled with liquid helium produced through Joule-Thomson valves. It is also equipped with numerous cryogenic components, including control valves, flow meters, and safety valves, enabling experimental operation to be carried out directly by the ACPS itself and thereby reducing the cryogenic requirements imposed on the experiments. To support a wide range of experiments, the ACPS provides three transfer lines that deliver different levels of cooling power.

preprint2026arXiv

Optomechanical platform for high-frequency gravitational wave and vector dark matter detection

We present a proposal for a nanomechanical membrane resonator integrated into a moderate-finesse (F∼10\mathcal{F}\sim 10) optical cavity as a versatile platform for detecting high-frequency gravitational waves and vector dark matter. Gravitational-wave sensitivity arises from cavity-length modulation, which resonantly drives membrane motion via the radiation-pressure force. This force also enables in situ tuning of the membrane's resonance frequency by nearly a factor of two, allowing a frequency coverage from 0.5 to 40 kHz using six membranes. The detector achieves a peak strain sensitivity of 2×10−23/Hz2\times 10^{-23}/\sqrt{\text{Hz}} at 40 kHz. Using a silicon membrane positioned near a gallium-arsenide input mirror additionally provides sensitivity to vector dark matter via differential acceleration from their differing atomic-to-mass number ratios. The projected reach surpasses the existing limits in the range of 2×10−122\times 10^{-12} to 2×10−102\times 10^{-10} eV/c2\text{eV}/c^2 for a one-year measurement. Consequently, the proposed detector offers a unified approach to searching for physics beyond the Standard Model, probing both high-frequency gravitational waves and vector dark matter.

preprint2016arXiv

Etch-Tuning and Design of Silicon Nitride Photonic Crystal Reflectors

By patterning a freestanding dielectric membrane into a photonic crystal reflector (PCR), it is possible to resonantly enhance its normal-incidence reflectivity, thereby realizing a thin, single-material mirror. In many PCR applications, the operating wavelength (e.g. that of a low-noise laser or emitter) is not tunable, imposing tolerances on crystal geometry that are not reliably achieved with standard nanolithography. Here we present a gentle technique to finely tune the resonant wavelength of a SiN PCR using iterative hydrofluoric acid etches. With little optimization, we achieve a 57-nm-thin photonic crystal having an operating wavelength within 0.15 nm (0.04 resonance linewidths) of our target (1550 nm). Our thin structure exhibits a broader and less pronounced transmission dip than is predicted by plane wave simulations, and we identify two effects leading to these discrepancies, both related to the divergence angle of a collimated laser beam. To overcome this limitation in future devices, we distill a series of simulations into a set of general design considerations for realizing robust, high-reflectivity resonances.

preprint2015arXiv

Enhanced Optomechanical Levitation of Minimally Supported Dielectrics

Optically levitated mechanical sensors promise isolation from thermal noise far beyond what is possible using flexible materials alone. One way to access this potential is to apply a strong optical trap to a minimally supported mechanical element, thereby increasing its quality factor QmQ_m. Current schemes, however, require prohibitively high laser power (∼10\sim10 W), and the QmQ_m enhancement is ultimately limited to a factor of ∼\sim 50 by hybridization between the trapped mode and the dissipative modes of the supporting structure. Here we propose a levitation scheme taking full advantage of an optical resonator to reduce the circulating power requirements by many orders of magnitude. Applying this scheme to the case of a dielectric disk in a Fabry-Perot cavity, we find a tilt-based tuning mechanism for optimizing both center-of-mass and torsional mode traps. Notably, the two modes are trapped with comparable efficiency, and we estimate that a 10-micron-diameter, 100-nm-thick Si disc could be trapped to a frequency of ∼\sim 10 MHz with only 3030 mW circulating in a cavity of (modest) finesse 1500. Finally, we simulate the effect such a strong trap would have on a realistic doubly-tethered disc. Of central importance, we find torsional motion is comparatively immune to QmQ_m-limiting hybridization, allowing a QmQ_m enhancement factor of ∼\sim 1500. This opens the possibility of realizing a laser-tuned 10 MHz mechanical system with a quality factor of order a billion.

Research graph

See the researcher in context

Open full explorer

Inspect adjacent papers, topics, institutions and collaborators without losing the researcher page.

Building this map preview

BZPEER is loading the nearby papers, people, topics and institutions for this page.