Source author record

Christoph Klemenjak

Christoph Klemenjak appears in the imported research catalog. Authorship, coauthor and topic links are available while profile ownership is still unclaimed.

ResearcherUnclaimed source record

Catalog footprint

What is connected

4works
5topics
4close collaborators

Actions

Connect this record

Log in to claim

Research graph

See the researcher in context

Open full explorer

Inspect adjacent papers, topics, institutions and collaborators without losing the researcher page.

Building this map preview

BZPEER is loading the nearby papers, people, topics and institutions for this page.

Published work

4 published item(s)

preprint2020arXiv

Augmenting an Assisted Living Lab with Non-Intrusive Load Monitoring

The need for reducing our energy consumption footprint and the increasing number of electric devices in today's homes is calling for new solutions that allow users to efficiently manage their energy consumption. Real-time feedback at device level would be of a significant benefit for this application. In addition, the aging population and their wish to be more autonomous have motivated the use of this same real-time data to indirectly monitor the household's occupants for their safety. By breaking down aggregate power consumption into its components, Non-Intrusive Load Monitoring provides information on individual appliances and their current state of operation. Since no additional metering equipment is required, residents are not confronted with intrusion into their familiar environment. Our work aims to depict an architecture supporting non-intrusive measurement with a smart electricity meter and the handling of these data using an open-source platform that allows to visualize and process real-time data about the total energy consumed. As a case study, we describe a series of measurements from common household devices and show how abnormal behavior can be detected.

preprint2020arXiv

Exploring Bayesian Surprise to Prevent Overfitting and to Predict Model Performance in Non-Intrusive Load Monitoring

Non-Intrusive Load Monitoring (NILM) is a field of research focused on segregating constituent electrical loads in a system based only on their aggregated signal. Significant computational resources and research time are spent training models, often using as much data as possible, perhaps driven by the preconception that more data equates to more accurate models and better performing algorithms. When has enough prior training been done? When has a NILM algorithm encountered new, unseen data? This work applies the notion of Bayesian surprise to answer these questions which are important for both supervised and unsupervised algorithms. We quantify the degree of surprise between the predictive distribution (termed postdictive surprise), as well as the transitional probabilities (termed transitional surprise), before and after a window of observations. We compare the performance of several benchmark NILM algorithms supported by NILMTK, in order to establish a useful threshold on the two combined measures of surprise. We validate the use of transitional surprise by exploring the performance of a popular Hidden Markov Model as a function of surprise threshold. Finally, we explore the use of a surprise threshold as a regularization technique to avoid overfitting in cross-dataset performance. Although the generality of the specific surprise threshold discussed herein may be suspect without further testing, this work provides clear evidence that a point of diminishing returns of model performance with respect to dataset size exists. This has implications for future model development, dataset acquisition, as well as aiding in model flexibility during deployment.

preprint2020arXiv

Towards Comparability in Non-Intrusive Load Monitoring: On Data and Performance Evaluation

Non-Intrusive Load Monitoring (NILM) comprises of a set of techniques that provide insights into the energy consumption of households and industrial facilities. Latest contributions show significant improvements in terms of accuracy and generalisation abilities. Despite all progress made concerning disaggregation techniques, performance evaluation and comparability remains an open research question. The lack of standardisation and consensus on evaluation procedures makes reproducibility and comparability extremely difficult. In this paper, we draw attention to comparability in NILM with a focus on highlighting the considerable differences amongst common energy datasets used to test the performance of algorithms. We divide discussion on comparability into data aspects, performance metrics, and give a close view on evaluation processes. Detailed information on pre-processing as well as data cleaning methods, the importance of unified performance reporting, and the need for complexity measures in load disaggregation are found to be the most urgent issues in NILM-related research. In addition, our evaluation suggests that datasets should be chosen carefully. We conclude by formulating suggestions for future work to enhance comparability.

preprint2014arXiv

YoMo - The Arduino based Smart Metering Board

Smart meters are an enabling technology for many smart grid applications. This paper introduces a design for a low-cost smart meter system as well as the fundamentals of smart metering. The smart meter platform, provided as open hardware, is designed with a connector interface compatible to the Arduino platform, thus opening the possibilities for smart meters with flexible hardware and computation features, starting from low-cost 8 bit micro controllers up to powerful single board computers that can run Linux. The metering platform features a current transformer which allows a non-intrusive installation of the current measurement unit. The suggested design can switch loads, offers a variable sampling frequency, and provides measurement data such as active power, reactive and apparent power. Results indicate that measurement accuracy and resolution of the proposed metering platform are sufficient for a range of different applications and loads from a few watts up to five kilowatts.