Source author record

Dominik Egarter

Dominik Egarter appears in the imported research catalog. Authorship, coauthor and topic links are available while profile ownership is still unclaimed.

ResearcherUnclaimed source record

Catalog footprint

What is connected

6works
4topics
4close collaborators

Actions

Connect this record

Log in to claim

Research graph

See the researcher in context

Open full explorer

Inspect adjacent papers, topics, institutions and collaborators without losing the researcher page.

Building this map preview

BZPEER is loading the nearby papers, people, topics and institutions for this page.

Published work

6 published item(s)

preprint2015arXiv

An Open Solution to Provide Personalized Feedback for Building Energy Management

The integration of renewable energy sources increases the complexity in mantaining the power grid. In particular, the highly dynamic nature of generation and consumption demands for a better utilization of energy resources, which seen the cost of storage infrastructure, can only be achieved through demand-response. Accordingly, the availability of energy and potential overload situations can be reflected using a price signal. The effectiveness of this mechanism arises from the flexibility of device operation, which is nevertheless heavily reliant on the exchange of information between the grid and its consumers. In this paper, we investigate the capability of an interactive energy management system to timely inform users on energy usage, in order to promote an optimal use of local resources. In particular, we analyze data being collected in several households in Italy and Austria to gain insights into usage behavior and drive the design of more effective systems. The outcome is the formulation of energy efficiency policies for residential buildings, as well as the design of an energy management system, consisting of hardware measurement units and a management software. The Mjölnir framework, which we release for open use, provides a platform where various feedback concepts can be implemented and assessed. This includes widgets displaying disaggregated and aggregated consumption information, as well as daily production and tailored advices. The formulated policies were implemented as an advisor widget able to autonomously analyze usage and provide tailored energy feedback.

preprint2015arXiv

Complexity of Power Draws for Load Disaggregation

Non-Intrusive Load Monitoring (NILM) is a technology offering methods to identify appliances in homes based on their consumption characteristics and the total household demand. Recently, many different novel NILM approaches were introduced, tested on real-world data and evaluated with a common evaluation metric. However, the fair comparison between different NILM approaches even with the usage of the same evaluation metric is nearly impossible due to incomplete or missing problem definitions. Each NILM approach typically is evaluated under different test scenarios. Test results are thus influenced by the considered appliances, the number of used appliances, the device type representing the appliance and the pre-processing stages denoising the consumption data. This paper introduces a novel complexity measure of aggregated consumption data providing an assessment of the problem complexity affected by the used appliances, the appliance characteristics and the appliance usage over time. We test our load disaggregation complexity on different real-world datasets and with a state-of-the-art NILM approach. The introduced disaggregation complexity measure is able to classify the disaggregation problem based on the used appliance set and the considered measurement noise.

preprint2015arXiv

Proficiency of Power Values for Load Disaggregation

Load disaggregation techniques infer the operation of different power consuming devices from a single measurement point that records the total power draw over time. Thus, a device consuming power at the moment can be understood as information encoded in the power draw. However, similar power draws or similar combinations of power draws limit the ability to detect the currently active device set. We present an information coding perspective of load disaggregation to enable a better understanding of this process and to support its future improvement. In typical cases of quantity and type of devices and their respective power consumption, not all possible device configurations can be mapped to distinguishable power values. We introduce the term of proficiency to describe the suitability of a device set for load disaggregation. We provide the notion and calculation of entropy of initial device states, mutual information of power values and the resulting uncertainty coefficient or proficiency. We show that the proficiency is highly dependent from the device running probability especially for devices with multiple states of power consumption. The application of the concept is demonstrated by exemplary artificial data as well as with actual power consumption data from real-world power draw datasets.

preprint2014arXiv

GREEND: An Energy Consumption Dataset of Households in Italy and Austria

Home energy management systems can be used to monitor and optimize consumption and local production from renewable energy. To assess solutions before their deployment, researchers and designers of those systems demand for energy consumption datasets. In this paper, we present the GREEND dataset, containing detailed power usage information obtained through a measurement campaign in households in Austria and Italy. We provide a description of consumption scenarios and discuss design choices for the sensing infrastructure. Finally, we benchmark the dataset with state-of-the-art techniques in load disaggregation, occupancy detection and appliance usage mining.

preprint2014arXiv

Integration of Legacy Appliances into Home Energy Management Systems

The progressive installation of renewable energy sources requires the coordination of energy consuming devices. At consumer level, this coordination can be done by a home energy management system (HEMS). Interoperability issues need to be solved among smart appliances as well as between smart and non-smart, i.e., legacy devices. We expect current standardization efforts to soon provide technologies to design smart appliances in order to cope with the current interoperability issues. Nevertheless, common electrical devices affect energy consumption significantly and therefore deserve consideration within energy management applications. This paper discusses the integration of smart and legacy devices into a generic system architecture and, subsequently, elaborates the requirements and components which are necessary to realize such an architecture including an application of load detection for the identification of running loads and their integration into existing HEM systems. We assess the feasibility of such an approach with a case study based on a measurement campaign on real households. We show how the information of detected appliances can be extracted in order to create device profiles allowing for their integration and management within a HEMS.

preprint2014arXiv

YoMo - The Arduino based Smart Metering Board

Smart meters are an enabling technology for many smart grid applications. This paper introduces a design for a low-cost smart meter system as well as the fundamentals of smart metering. The smart meter platform, provided as open hardware, is designed with a connector interface compatible to the Arduino platform, thus opening the possibilities for smart meters with flexible hardware and computation features, starting from low-cost 8 bit micro controllers up to powerful single board computers that can run Linux. The metering platform features a current transformer which allows a non-intrusive installation of the current measurement unit. The suggested design can switch loads, offers a variable sampling frequency, and provides measurement data such as active power, reactive and apparent power. Results indicate that measurement accuracy and resolution of the proposed metering platform are sufficient for a range of different applications and loads from a few watts up to five kilowatts.