Researcher profile

Christina Boemer

Christina Boemer contributes to research discovery and scholarly infrastructure.

ResearcherAffiliation not importedOpen to collaborate

Trust snapshot

Quick read

Trust 13 - UnverifiedVerification L1Unclaimed author
2works
0followers
2topics
4close collaborators

Actions

Decide how to stay connected

Follow researcher0

Identity and collaboration

How to connect with this researcher

Claiming links this public author record to a researcher profile and unlocks direct collaboration workflows.

Log in to claim

Direct collaboration

Open a focused conversation when the fit is right

Claim this author entity first to unlock direct invitations.

Research graph

See the researcher in context

Open full explorer

Inspect adjacent work, topics, institutions and collaborators without jumping out to a separate graph page.

Building this graph slice

BZPEER is loading the nearby papers, people, topics and institutions for this page.

Published work

2 published item(s)

preprint2021arXiv

A self-referenced in-situ arrival time monitor for X-ray free-electron lasers

We present a novel, highly versatile, and self-referenced arrival time monitor for measuring the femtosecond time delay between a hard X-ray pulse from a free-electron laser and an optical laser pulse, measured directly on the same sample used for pump-probe experiments. Two chirped and picosecond long optical supercontinuum pulses traverse the sample with a mutually fixed time delay of 970 fs, while a femtosecond X-ray pulse arrives at an instant in between both pulses. Behind the sample the supercontinuum pulses are temporally overlapped to yield near-perfect destructive interference in the absence of the X-ray pulse. Stimulation of the sample with an X-ray pulse delivers non-zero contributions at certain optical wavelengths, which serve as a measure of the relative arrival time of the X-ray pulse with an accuracy of better than 25 fs. We find an excellent agreement of our monitor with the existing timing diagnostics at the SACLA XFEL with a Pearson correlation value of 0.98. We demonstrate a high sensitivity to measure X-ray pulses with pulse energies as low as 30 $μ$J. Using a free-flowing liquid jet as interaction sample ensures the full replacement of the sample volume for each X-ray/optical event, thus enabling its utility even at MHz repetition rate XFEL sources.

preprint2020arXiv

X-ray parametric down-conversion: Challenging previous findings on the basis of improved experimental methods

X-ray parametric down-conversion is a fundamental nonlinear effect that promises a wide range of possible applications. Nevertheless, it has been scarcely investigated and unequivocal evidence of the effect is still missing for certain spectral regions. In particular, this is the case for down-conversion into pairs of x-ray and optical photons, which would open pathways to characterise and image valence electron-density fluctuations. In this work, we present a systematic approach to scan the parameter space, wherein we expect to identify the effect based on its characteristic signature. Within the resolution of the experimental setup we cannot establish any evidence for the nonlinear effect. Instead, we trace the measured signals back to elastic scattering contributions, thereby challenging the interpretation of previous studies on the effect of x-ray parametric down conversion producing photons in the visible spectral range. As a benchmark for future investigations of x-ray parametric down-conversion - both experimental and theoretical - we extract an upper bound for the effect's conversion efficiency of $10^{-11}$ within the resolution of our setup.