Researcher profile

Carlos Alberola-López

Carlos Alberola-López contributes to research discovery and scholarly infrastructure.

ResearcherAffiliation not importedOpen to collaborate

Trust snapshot

Quick read

Trust 13 - Baseline
2works
0followers
3topics
4close collaborators

Actions

Decide how to stay connected

Follow researcher0

Research graph

See the researcher in context

Open full explorer

Inspect adjacent work, topics, institutions and collaborators without jumping out to a separate graph page.

Building this graph slice

BZPEER is loading the nearby papers, people, topics and institutions for this page.

Published work

2 published item(s)

preprint2023arXiv

Physics-informed self-supervised deep learning reconstruction for accelerated first-pass perfusion cardiac MRI

First-pass perfusion cardiac magnetic resonance (FPP-CMR) is becoming an essential non-invasive imaging method for detecting deficits of myocardial blood flow, allowing the assessment of coronary heart disease. Nevertheless, acquisitions suffer from relatively low spatial resolution and limited heart coverage. Compressed sensing (CS) methods have been proposed to accelerate FPP-CMR and achieve higher spatial resolution. However, the long reconstruction times have limited the widespread clinical use of CS in FPP-CMR. Deep learning techniques based on supervised learning have emerged as alternatives for speeding up reconstructions. However, these approaches require fully sampled data for training, which is not possible to obtain, particularly high-resolution FPP-CMR images. Here, we propose a physics-informed self-supervised deep learning FPP-CMR reconstruction approach for accelerating FPP-CMR scans and hence facilitate high spatial resolution imaging. The proposed method provides high-quality FPP-CMR images from 10x undersampled data without using fully sampled reference data.

preprint2016arXiv

Exact Calculation of Noise Maps and g-Factor in GRAPPA using a k-space Analysis

Noise characterization in MRI has multiple applications, including quality assurance and protocol optimization. It is particularly important in the presence of parallel imaging acceleration, where the noise distribution can contain severe spatial heterogeneities. If the parallel imaging reconstruction is a linear process, an exact noise analysis is possible by taking into account the correlations between all the samples involved. However, for k-space based techniques like GRAPPA, the exact analysis has been considered computationally prohibitive due to the very large size of the noise covariance matrices required to characterize the noise propagation from k-space to image-space. Previous methods avoid this computational burden by approximating the GRAPPA reconstruction as a pixel-wise linear operation performed in the image-space. However, these methods are not exact in the presence of non-uniform k-space undersampling (e.g.: containing a calibration region). For this reason, in this work we develop an exact characterization of the noise distribution for self-calibrated parallel imaging in the presence of arbitrary Cartesian undersampling patterns. By exploiting the symmetries and separability in the noise propagation process, the proposed method is computationally efficient and does not require large matrices. In this manuscript, we present the proposed noise characterization method and compare it to previous techniques using Monte-Carlo simulations as well as phantom acquisitions.