Source author record

Ebraham Alskaf

Ebraham Alskaf appears in the imported research catalog. Authorship, coauthor and topic links are available while profile ownership is still unclaimed.

ResearcherUnclaimed source record

Catalog footprint

What is connected

2works
3topics
4close collaborators

Actions

Connect this record

Log in to claim

Research graph

See the researcher in context

Open full explorer

Inspect adjacent papers, topics, institutions and collaborators without losing the researcher page.

Building this map preview

BZPEER is loading the nearby papers, people, topics and institutions for this page.

Published work

2 published item(s)

preprint2023arXiv

Physics-informed self-supervised deep learning reconstruction for accelerated first-pass perfusion cardiac MRI

First-pass perfusion cardiac magnetic resonance (FPP-CMR) is becoming an essential non-invasive imaging method for detecting deficits of myocardial blood flow, allowing the assessment of coronary heart disease. Nevertheless, acquisitions suffer from relatively low spatial resolution and limited heart coverage. Compressed sensing (CS) methods have been proposed to accelerate FPP-CMR and achieve higher spatial resolution. However, the long reconstruction times have limited the widespread clinical use of CS in FPP-CMR. Deep learning techniques based on supervised learning have emerged as alternatives for speeding up reconstructions. However, these approaches require fully sampled data for training, which is not possible to obtain, particularly high-resolution FPP-CMR images. Here, we propose a physics-informed self-supervised deep learning FPP-CMR reconstruction approach for accelerating FPP-CMR scans and hence facilitate high spatial resolution imaging. The proposed method provides high-quality FPP-CMR images from 10x undersampled data without using fully sampled reference data.

preprint2020arXiv

Left atrial ejection fraction estimation using SEGANet for fully automated segmentation of CINE MRI

Atrial fibrillation (AF) is the most common sustained cardiac arrhythmia, characterised by a rapid and irregular electrical activation of the atria. Treatments for AF are often ineffective and few atrial biomarkers exist to automatically characterise atrial function and aid in treatment selection for AF. Clinical metrics of left atrial (LA) function, such as ejection fraction (EF) and active atrial contraction ejection fraction (aEF), are promising, but have until now typically relied on volume estimations extrapolated from single-slice images. In this work, we study volumetric functional biomarkers of the LA using a fully automatic SEGmentation of the left Atrium based on a convolutional neural Network (SEGANet). SEGANet was trained using a dedicated data augmentation scheme to segment the LA, across all cardiac phases, in short axis dynamic (CINE) Magnetic Resonance Images (MRI) acquired with full cardiac coverage. Using the automatic segmentations, we plotted volumetric time curves for the LA and estimated LA EF and aEF automatically. The proposed method yields high quality segmentations that compare well with manual segmentations (Dice scores [$0.93 \pm 0.04$], median contour [$0.75 \pm 0.31$] mm and Hausdorff distances [$4.59 \pm 2.06$] mm). LA EF and aEF are also in agreement with literature values and are significantly higher in AF patients than in healthy volunteers. Our work opens up the possibility of automatically estimating LA volumes and functional biomarkers from multi-slice CINE MRI, bypassing the limitations of current single-slice methods and improving the characterisation of atrial function in AF patients.