Researcher profile

Bernhard Lendl

Bernhard Lendl contributes to research discovery and scholarly infrastructure.

ResearcherAffiliation not importedOpen to collaborate

Trust snapshot

Quick read

Trust 17 - UnverifiedVerification L1Unclaimed author
4works
0followers
5topics
4close collaborators

Actions

Decide how to stay connected

Follow researcher0

Identity and collaboration

How to connect with this researcher

Claiming links this public author record to a researcher profile and unlocks direct collaboration workflows.

Log in to claim

Direct collaboration

Open a focused conversation when the fit is right

Claim this author entity first to unlock direct invitations.

Research graph

See the researcher in context

Open full explorer

Inspect adjacent work, topics, institutions and collaborators without jumping out to a separate graph page.

Building this graph slice

BZPEER is loading the nearby papers, people, topics and institutions for this page.

Published work

4 published item(s)

preprint2020arXiv

Correlative infrared optical coherence tomography and hyperspectral chemical imaging

Optical coherence tomography (OCT) is a high-resolution three-dimensional imaging technique that enables non-destructive measurements of surface and subsurface microstructures. Recent developments of OCT operating in the mid-infrared (MIR) range (around 4 μm) lifted fundamental scattering limitations and initiated applied material research in formerly inaccessible fields. The MIR spectral region, however, is also of great interest for spectroscopy and hyperspectral imaging, which allow highly selective and sensitive chemical studies of materials. In this contribution, we introduce an OCT system (dual-band, central wavelengths of 2 μm m and 4 μm) combined with MIR spectroscopy that is implemented as a raster scanning chemical imaging modality. The fully-integrated and cost-effective optical instrument is based on a single supercontinuum laser source (emission spectrum spanning from 1.1 μm to 4.4 μm). Capabilities of the in-situ correlative measurements are experimentally demonstrated by obtaining complex multidimensional material data, comprising morphological and chemical information, from a multi-layered composite ceramic-polymer specimen.

preprint2020arXiv

Resonant Tunneling Diodes Strongly Coupled to the Cavity Field

We demonstrate Resonant Tunneling Diodes, embedded in double metal cavities, strongly coupled to the cavity field, while maintaining their electronic properties. We measure the polariton dispersion and find a relative vacuum Rabi splitting of 16%, which explicitly qualifies for the strong-coupling regime. Additionally we show that electronic transport has a significant influence on the polaritons by modulating the coupling strength. The merge between electronic transport and polaritonic physics in our devices opens up a new aspect of cavity quantum electro-dynamics and integrated photonics.

preprint2020arXiv

Sensitivity-enhanced Fourier transform mid-infrared spectroscopy using a supercontinuum laser source

Fourier transform infrared (FTIR) spectrometers have been the dominant technology in the field of mid-infrared (MIR)spectroscopy for decades. Supercontinuum laser sources operating in the MIR spectral region now offer the potential to enrich the field of FTIR spectroscopy due to their distinctive properties, such as high-brightness, broadband spectral coverage and enhanced stability. In our contribution, we introduce this advanced light source as a replacement for conventional thermal emitters. Furthermore, an approach to efficient coupling of pulsed MIR supercontinuum sources to FTIR spectrometers is proposed and considered in detail. The experimental part is devoted to pulse-to-pulse energy fluctuations of the applied supercontinuum laser, performance of the system, as well as the noise and long-term stability. Comparative measurements performed with a conventional FTIR instrument equipped with a thermal emitter illustrate that similar noise levels can be achieved with the supercontinuum-based system. The analytical performance of the supercontinuum-based FTIR spectrometer was tested for a concentration series of aqueous formaldehyde solutions in a liquid flow cell (500 $μ$m path length) and compared with the conventional FTIR (130 $μ$m path length). The results show a four-times-enhanced detection limit due to the extended path length enabled by the high brightness of the laser. In conclusion, FTIR spectrometers equipped with novel broadband MIR supercontinuum lasers could outperform traditional systems providing superior performance, e.g., interaction path lengths formerly unattainable, while maintaining low noise levels known from highly stable thermal emitters.

preprint2020arXiv

Ultra-sensitive refractive index gas sensor with functionalized silicon nitride photonic circuits

Portable and cost-effective gas sensors are gaining demand for a number of environmental, biomedical and industrial applications, yet current devices are confined into specialized labs and cannot be extended to general use. Here, we demonstrate a part-per-billion-sensitive refractive index gas sensor on a photonic chip based on silicon nitride waveguides functionalized with a mesoporous silica top-cladding layer. Low-concentration chemical vapors are detected by monitoring the output spectral pattern of an integrated Mach-Zehnder interferometer having one coated arm exposed to the gas vapors. We retrieved a limit of detection of 65 ppb, 247 ppb and 1.6 ppb for acetone, isopropyl alcohol and ethanol, respectively. Our on-chip refractive index sensor provides, to the best of our knowledge, an unprecedented sensitivity for low gas concentrations based on photonic integrated circuits. As such, our results herald the implementation of compact, portable and inexpensive devices for on-site and real-time environmental monitoring and medical diagnostics.