Source author record

Benjamin J. Reschovsky

Benjamin J. Reschovsky appears in the imported research catalog. Authorship, coauthor and topic links are available while profile ownership is still unclaimed.

ResearcherUnclaimed source record

Catalog footprint

What is connected

2works
5topics
4close collaborators

Actions

Connect this record

Log in to claim

Research graph

See the researcher in context

Open full explorer

Inspect adjacent papers, topics, institutions and collaborators without losing the researcher page.

Building this map preview

BZPEER is loading the nearby papers, people, topics and institutions for this page.

Published work

2 published item(s)

preprint2026arXiv

Electro-optic frequency comb Doppler thermometry

We demonstrate a Doppler thermometer based on direct optical frequency comb spectroscopy of an $^{85}$Rb vapor with a chirped electro-optic frequency comb (EOFC). The direct EOFC Doppler thermometer is accurate to within its approximately 1 K statistical uncertainty. We experimentally compare direct EOFC spectroscopy with conventional Doppler spectroscopy using a single-frequency, step-scanned laser probe. Our results show that direct EOFC spectroscopy mitigates transit-induced optical pumping distortion of the atomic lineshape, which is the dominant systematic temperature shift in alkali atom Doppler thermometry. Optical Bloch equation simulations of conventional and direct EOFC Doppler spectroscopy confirm that EOFC spectroscopy can use higher optical power to reduce statistical noise without optical pumping distortion. Our results indicate that EOFC Doppler thermometry is a promising approach to realizing a primary thermometer with size and measurement rate sufficient for applications including pharmaceutical manufacturing and nuclear waste monitoring.

preprint2022arXiv

Intrinsically accurate sensing with an optomechanical accelerometer

We demonstrate a microfabricated optomechanical accelerometer that is capable of percent-level accuracy without external calibration. To achieve this capability, we use a mechanical model of the device behavior that can be characterized by the thermal noise response along with an optical frequency comb readout method that enables high sensitivity, high bandwidth, high dynamic range, and SI-traceable displacement measurements. The resulting intrinsic accuracy was evaluated over a wide frequency range by comparing to a primary vibration calibration system and local gravity. The average agreement was found to be 2.1 % for the calibration system between 0.1 kHz and 15 kHz and better than 0.2 % for the static acceleration. This capability has the potential to replace costly external calibrations and improve the accuracy of inertial guidance systems and remotely deployed accelerometers. Due to the fundamental nature of the intrinsic accuracy approach, it could be extended to other optomechanical transducers, including force and pressure sensors.