Source author record

Benedikt Vormwald

Benedikt Vormwald appears in the imported research catalog. Authorship, coauthor and topic links are available while profile ownership is still unclaimed.

ResearcherUnclaimed source record

Catalog footprint

What is connected

7works
4topics
4close collaborators

Actions

Connect this record

Log in to claim

Research graph

See the researcher in context

Open full explorer

Inspect adjacent papers, topics, institutions and collaborators without losing the researcher page.

Building this map preview

BZPEER is loading the nearby papers, people, topics and institutions for this page.

Published work

7 published item(s)

preprint2022arXiv

The tracking detector of the FASER experiment

FASER is a new experiment designed to search for new light weakly-interacting long-lived particles (LLPs) and study high-energy neutrino interactions in the very forward region of the LHC collisions at CERN. The experimental apparatus is situated 480 m downstream of the ATLAS interaction-point aligned with the beam collision axis. The FASER detector includes four identical tracker stations constructed from silicon microstrip detectors. Three of the tracker stations form a tracking spectrometer, and enable FASER to detect the decay products of LLPs decaying inside the apparatus, whereas the fourth station is used for the neutrino analysis. The spectrometer has been installed in the LHC complex since March 2021, while the fourth station is not yet installed. FASER will start physics data taking when the LHC resumes operation in early 2022. This paper describes the design, construction and testing of the tracking spectrometer, including the associated components such as the mechanics, readout electronics, power supplies and cooling system.

preprint2022arXiv

The trigger and data acquisition system of the FASER experiment

The FASER experiment is a new small and inexpensive experiment that is placed 480 meters downstream of the ATLAS experiment at the CERN LHC. FASER is designed to capture decays of new long-lived particles, produced outside of the ATLAS detector acceptance. These rare particles can decay in the FASER detector together with about 500-1000 Hz of other particles originating from the ATLAS interaction point. A very high efficiency trigger and data acquisition system is required to ensure that the physics events of interest will be recorded. This paper describes the trigger and data acquisition system of the FASER experiment and presents performance results of the system acquired during initial commissioning.

preprint2015arXiv

A Calibration System for Compton Polarimetry at $e^+e^-$ Linear Colliders

Polarimetry with permille-level precision is essential for future electron-positron linear colliders. Compton polarimeters can reach negligible statistical uncertainties within seconds of measurement time. The dominating systematic uncertainties originate from the response and alignment of the detector which records the Compton scattered electrons. The robust baseline technology for the Compton polarimeters foreseen at future linear colliders is based on an array of gas Cherenkov detectors read out by photomultipliers. In this paper, we will present a calibration method which promises to monitor nonlinearities in the response of such a detector at the level of a few permille. This method has been implemented in an LED-based calibration system which matches the existing prototype detector. The performance of this calibration system is sufficient to control the corresponding contribution to the total uncertainty on the extracted polarisation to better than $0.1\%$.

preprint2015arXiv

A Quartz Cherenkov Detector for Compton-Polarimetry at Future e+e- Colliders

Precision polarimetry is essential for future e+ e- colliders and requires Compton polarimeters designed for negligible statistical uncertainties. In this paper, we discuss the design and construction of a quartz Cherenkov detector for such Compton polarimeters. The detector concept has been developed with regard to the main systematic uncertainties of the polarisation measurements, namely the linearity of the detector response and detector alignment. Simulation studies presented here imply that the light yield reachable by using quartz as Cherenkov medium allows to resolve in the Cherenkov photon spectra individual peaks corresponding to different numbers of Compton electrons. The benefits of the application of a detector with such single-peak resolution to the polarisation measurement are shown for the example of the upstream polarimeters foreseen at the International Linear Collider. Results of a first testbeam campaign with a four-channel prototype confirming simulation predictions for single electrons are presented.

preprint2014arXiv

Bilinear R Parity Violation at the ILC - Neutrino Physics at Colliders

Supersymmetry (SUSY) with bilinearly broken R parity (bRPV) offers an attractive possibility to explain the origin of neutrino masses and mixings. In such scenarios, the study of neutralino decays at colliders gives access to neutrino sector parameters. The ILC offers a very clean environment to study the neutralino properties as well as its subsequent decays, which typically involve a $W$ or $Z$ boson and a lepton. This study is based on ILC beam parameters according to the Technical Design Report for a center of mass energy of $500\,\mathrm{GeV}$. A full detector simulation of the International Large Detector (ILD) was performed for all Standard Model backgrounds and for $\widetildeχ_1^0$-pair production within a simplified model. The bRPV parameters are fixed according to current neutrino data. In this scenario, the $\widetildeχ_1^0$ mass can be reconstructed with an uncertainty of $δm = (40(\text{stat.}) + 50(\text{syst.}))\,\mathrm{MeV}$ for an integrated luminosity of $500\,\mathrm{fb}^{-1}$ from direct $\widetildeχ_1^0$-pair production, thus, to a large extent independently of the rest of the SUSY spectrum. The achievable precision on the atmospheric neutrino mixing angle $\sin^2 θ_{23}$ from measuring the neutralino branching fractions $\mathrm{BR}(\widetildeχ_1^0 \rightarrow W μ)$ and $\mathrm{BR}(\widetildeχ_1^0 \rightarrow W τ)$ at the ILC is better than current uncertainties from neutrino experiments. Thus, the ILC could have the opportunity to unveil the mechanism of neutrino mass generation.

preprint2014arXiv

Polarisation and Beam Energy Measurement at a Linear $e^+e^-$ Collider

The International Linear Collider (ILC) is a future electron/positron collider at the energy frontier. Its physics goals are clearly focused on precision measurements at the electroweak scale and beyond. Beam energy and beam polarisation are two important beam parameters, which need to be measured and monitored to any possible precision. We discuss in this publication the foreseen concepts of beam energy and beam polarisation measurement at the ILC: Two Compton polarimeters per beam line will determine the beam polarisation. The anticipated precision of this measurement amounts to $Δ\mathcal{P} / \mathcal{P} =2.5 \times 10^{-3}$, which is a challenging goal putting highest demands on detector alignment and linearity. Recent detector developments as well as a detector calibration technique are described, which allow for meeting these requirements. The beam energy is measured before and after the interaction point to a targeted precision of $ΔE/E = 10^{-4}$. Thereby, the two foreseen concepts are introduced: A noninvasive energy spectrometer based on beam position monitors is planned to be operated before the interaction region. Behind, a synchrotron radiation imaging detector will allow not only for measuring the beam energy, but also gives access to the beam energy spread of the (disrupted) beam.

preprint2014arXiv

Spin Transport and Polarimetry in the Beam Delivery System of the International Linear Collider

Polarised electron and positron beams are key ingredients to the physics programme of future linear colliders. Due to the chiral nature of weak interactions in the Standard Model - and possibly beyond - the knowledge of the luminosity-weighted average beam polarisation at the $e^+e^-$ interaction point is of similar importance as the knowledge of the luminosity and has to be controlled to permille-level precision in order to fully exploit the physics potential. The current concept to reach this challenging goal combines measurements from Laser-Compton polarimeters before and after the interaction point with measurements at the interaction point. A key element for this enterprise is the understanding of spin-transport effects between the polarimeters and the interaction point as well as collision effects. We show that without collisions, the polarimeters can be cross-calibrated to 0.1 %, and we discuss in detail the impact of collision effects and beam parameters on the polarisation value relevant for the interpretation of the $e^+e^-$ collision data.