Source author record

Jenny List

Jenny List appears in the imported research catalog. Authorship, coauthor and topic links are available while profile ownership is still unclaimed.

ResearcherUnclaimed source record

Catalog footprint

What is connected

39works
5topics
4close collaborators

Actions

Connect this record

Log in to claim

Research graph

See the researcher in context

Open full explorer

Inspect adjacent papers, topics, institutions and collaborators without losing the researcher page.

Building this map preview

BZPEER is loading the nearby papers, people, topics and institutions for this page.

Published work

39 published item(s)

preprint2023arXiv

The International Linear Collider: Report to Snowmass 2021

The International Linear Collider (ILC) is on the table now as a new global energy-frontier accelerator laboratory taking data in the 2030s. The ILC addresses key questions for our current understanding of particle physics. It is based on a proven accelerator technology. Its experiments will challenge the Standard Model of particle physics and will provide a new window to look beyond it. This document brings the story of the ILC up to date, emphasizing its strong physics motivation, its readiness for construction, and the opportunity it presents to the US and the global particle physics community.

preprint2022arXiv

Interplay of Beam Polarisation and Systematic Uncertainties in Electroweak Precision Measurements at Future $e^+ e^-$ Colliders

Future high-energy $\textrm{e}^+\textrm{e}^-$ colliders will provide some of the most precise tests of the Standard Model. Statistical uncertainties on electroweak precision observables and triple gauge couplings are expected to improve by orders of magnitude over current measurements. This provides a new challenge in accurately assessing and minimizing the impact of experimental systematic uncertainties. Beam polarization may hold a unique potential to isolate and determine the size of systematic effects. So far, studies have mainly focused on the statistical improvements from beam polarisation. This study aims to assess, for the first time, its impact on systematic uncertainties. A combined fit of precision observables, such as chiral fermion couplings and anomalous triple gauge couplings, together with experimental systematic effects is performed on generator-level differential distribution of 2-fermion and 4-fermion final-states. Different configurations of available beam polarisations and luminosities are tested with and without systematic effects, and will be discussed in the context of the existing projections on fermion and gauge boson couplings from detailed experimental simulations.

preprint2022arXiv

Polarized Electron Beams from Laser Plasma Acceleration and Their Polarimetry

In recent years, Laser Plasma Acceleration (LPA) has become a promising alternative to conventional RF accelerators. However, so far, it has only been theoretically shown that generating polarized LPA beams is possible. The LEAP (Laser Electron Acceleration with Polarization) project at DESY aims to demonstrate this experimentally for the first time, using a pre-polarized plasma target. The electron polarization will be measured with photon transmission polarimetry, which makes use of the production of circularly polarized bremsstrahlung during the passage of the electron beams through a suitable converter target. The photon polarization is then measured with the aid of transmission asymmetry arising from reversing the magnetization direction of an iron absorber. In this contribution an overview of the LEAP project is presented, detailing the generation of the polarized electron beams along with the design and simulation studies of the polarimeter.

preprint2021arXiv

ILC Study Questions for Snowmass 2021

To aid contributions to the Snowmass 2021 US Community Study on physics at the International Linear Collider and other proposed $e^+e^-$ colliders, we present a list of study questions that could be the basis of useful Snowmass projects. We accompany this with links to references and resources on $e^+e^-$ physics, and a description of a new software framework that we are preparing for $e^+e^-$ studies at Snowmass.

preprint2021arXiv

Polarised Beams at Future $e^+e^-$ Colliders

Beam polarisation is an integral part of the physics case of future Linear Colliders. In this contribution, important examples from Higgs coupling measurements, top and electroweak physics at high energies, the Z pole program as well as from searches for production of new particles will be reviewed. The full exploitation of its advantages requires the polarisation to be known at the permille-level. The a polarimetry concept based on the combination of Compton polarimeters, spin-tracking simulations and a global analysis of collision data which has been developed for the ILC to achieve the required precision will be presented.

preprint2020arXiv

Chargino production at the ILC

The lighter chargino, $\widetildeχ_1^{\pm}$, is a prime candidate to be the next-to-lightest SUSY particle (the NLSP). Several analyses of $\widetildeχ_1^{\pm}$ pair-production at the ILC, at specific model-points, have been performed, showing that detection and property-determination is possible, even for very difficult cases. However, no recent studies have evaluated the reach of the ILC to detect $\widetildeχ_1^{\pm}$ pair production in general. In this study, cross sections for $\widetildeχ_1^{\pm}$ pair production at the ILC were evaluated within a wide range of parameters. The aim was to determine the conditions for the lowest cross sections and compare these worst-case values with an estimation of the cross section limit for the observation of the lightest charginos at the ILC. The estimated limits were extrapolated from the studies performed at LEP, which can also be regarded as a worst-case scenario, since the tremendous advances in detector and accelerator technologies are disregarded

preprint2020arXiv

ILD benchmark: Quartic Gauge Couplings

The quartic gauge coupling (QGC) of the electroweak interaction can be used as a probe for physics beyond the Standard Model and has been previously measured at the Large Hadron Collider. However, to achieve sensitivity to small deviations the couplings must be measured with precision beyond the capability of a hadron collider. An electron-positron collider with center-of-mass energies in the TeV range can precisely probe the QGC and test a variety of models. The International Linear Collider is such a collider project with a possible extension to $1\,$TeV. In this note the critical reconstruction aspects of a QGC analysis in the vector boson scattering (VBS) channel of $e^+e^- \rightarrow ν\barν q\bar{q} q\bar{q}$ at $\sqrt{s}=1\,$TeV are identified for the International Large Detector. Generator level information from the event generator and simulation is used to gain access to influence of separate reconstruction effects. The separation of hadronic $WW$ and $ZZ$ decays by their invariant mass is chosen to quantify the strength of the effects. In the current simple reconstruction scheme the main obstacles are observed to be the removal of beam backgrounds, the jet clustering, and semi-leptonic decays within jets. At high center-of-mass energies of the VBS interaction jet clustering is found to no longer be a limiting factor. Points of optimizations are laid out for these aspects. In the case of semi-leptonic decays, proof-of-principal tests for corrections are performed and found to be challenging. A full analysis which includes the extraction of limits on anomalous QGCs remains open. Sensitivities similar to those achieved in generator level studies with approximated detector effects are expected.

preprint2020arXiv

ILD Benchmark: Search for Extra Scalars Produced in Association with a $Z$ boson at $\sqrt{s}=500$ GeV

We study the prospects for discovering an extra scalar boson $S^0$ at the International Linear Collider (ILC) based on a full simulation of the International Large Detector (ILD). In order to provide results in an as model-independent way as possible, the analysis uses the recoil of the scalar against a $Z$ boson decaying into a pair of muons, $e^+e^- \to μμS^{0}$. This process serves as a physics benchmark for the ILD detector performance at $\sqrt{s}=500$ GeV, specifically for the muon ID and momentum resolution, as well as for the identification of initial state radiation photons and their energy measurement. As final results, the sensitivities for discovering the extra scalars at 2 $σ$ level are evaluated in terms of a scale factor $\sin^2θ$ with respect to the Standard Model value of the cross section for the Higgs--strahlung process. Two detector models, IDR-L and IDR-S, are considered in the analysis, which differ in radius of the tracking volume, aspect ratio and strength of the magnetic field. While the two detector models show a visible difference in the precision of the reconstructed invariant di-muon mass, no difference is found at the level of the final results.

preprint2020arXiv

Precision measurements of Triple Gauge Couplings at future electron-positron colliders

A precise knowledge of charged Triple Gauge Couplings (cTGCs) is important for the determination of Higgs couplings and for constraining physics beyond the Standard Model. Future high-energy $e^{+}e^{-}$ colliders could have a significantly improved sensitivity to anomalous cTGCs. The fit framework presented here extracts cTGCs in parallel with chiral cross sections and beam polarisation parameters. It demonstrates that cTGCs can be measured with precision in the $10^{-3}-10^{-4}$ range. A strong dependence of the cTGC sensitivity on the available luminosities and polarisations is observed.

preprint2020arXiv

Prospects of measuring the branching fraction of the Higgs boson decaying into muon pairs at the International Linear Collider

The prospects for measuring the branching fraction of $H \to μ^+ μ^-$ at the International Linear Collider (ILC) have been evaluated based on a full detector simulation of the International Large Detector (ILD) concept, considering centre-of-mass energies ($\sqrt{s}$) of 250 GeV and 500 GeV. For both $\sqrt{s}$ cases, the two final states $e^+ e^- \to q\overline{q}H$ and $e^+ e^- \to ν\overlineνH$ have been analyzed. For integrated luminosities of 2 ab$^{-1}$ at $\sqrt{s} = 250$ GeV and 4 ab$^{-1}$ at $\sqrt{s} = 500$ GeV, the combined precision on the branching fraction of $H \to μ^+ μ^-$ is estimated to be 17{\%}. The impact of the transverse momentum resolution for this analysis is also studied.

preprint2020arXiv

WIMP Dark Matter at the International Linear Collider

In this study, the sensitivity of future lepton colliders to WIMP dark matter is evaluated assuming WIMP pair production accompanied by a photon from initial state radiation, through which the process can be identified. A full detector simulation for the International Large Detector (ILD) concept at the International Linear Collider (ILC) is performed for a \com energy of 500\,GeV. Energy scales of up to $3$\,TeV can be tested for different effective operators for WIMP masses almost up to half the \com energy. The sensitivity benefits from the polarised beams, which can reduce the main SM background from neutrino pair production substantially. In addition, systematic uncertainties are shown to be significantly reduced by combining data with several different polarisation configurations. In comparison to a previous study, the reconstruction of the forward detectors has been improved and the systematic uncertainties are fully treated. The results are also extrapolated to other \com energies, luminosities and beam polarisations. This allows to provide results for the full ILC programme, i.e.\ from 250\,GeV to 1\,TeV, as well as to give approximate results for other planned lepton colliders.

preprint2019arXiv

The ILC as a natural SUSY discovery machine and precision microscope: from light higgsinos to tests of unification

The requirement of electroweak naturalness in simple supersymmetric models implies the existence of a cluster of four light higgsinos with mass $\sim 100-300$\,GeV, the lighter the better. While such light compressed spectra may be challenging to observe at LHC, the International Linear $e^+e^-$ Collider (ILC) with $\sqrt{s}>2m_{\rm higgsino}$ would serve as both a SUSY discovery machine and a precision microscope. We study higgsino pair production signatures at the ILC based on full, \texttt{Geant4-}based simulation of the ILD detector concept. We examine several benchmark scenarios that may be challenging for discovery at HL-LHC due to mass differences between the higgsino states between $20$ and $4$\,GeV. Assuming $\sqrt{s}= 500$\,GeV and 1000\,fb$^{-1}$ of integrated luminosity, the individual higgsino masses can be measured to $1-2\%$ precision in case of the larger mass differences, and at the level of $5\%$ for the smallest mass difference case. The higgsino mass splittings are sensitive to the electroweak gaugino masses and allow extraction of gaugino masses to $\sim 3-20\%$ (depending on the model). Extrapolation of gaugino masses via renormalization group running can test the hypothesis of gaugino mass unification. We also examine a case with natural generalized mirage mediation where the unification of gaugino masses at an intermediate scale apparently gives rise to a natural SUSY spectrum somewhat beyond the reach of HL-LHC.

preprint2016arXiv

Dark matter relic density from observations of supersymmetry at the ILC

Supersymmetry can explain the observed dark matter relic density with a neutralino dark matter particle and a coannihilating, almost mass-degenerate sparticle. If this were the case in nature, a linear electron positron collider like the ILC could discover the two sparticles if their masses are in the kinematic reach of the collider. This contribution discusses which observations are necessary at the ILC for predicting the dark matter relic density correctly and for confirming that the observed lightest neutralino is the only kind of dark matter. We take the case of stau coannihilation as an example.

preprint2016arXiv

Implications of the 750 GeV gamma-gamma Resonance as a Case Study for the International Linear Collider

If the gamma-gamma resonance at 750 GeV suggested by 2015 LHC data turns out to be a real effect, what are the implications for the physics case and upgrade path of the International Linear Collider? Whether or not the resonance is confirmed, this question provides an interesting case study testing the robustness of the ILC physics case. In this note, we address this question with two points: (1) Almost all models proposed for the new 750 GeV particle require additional new particles with electroweak couplings. The key elements of the 500 GeV ILC physics program---precision measurements of the Higgs boson, the top quark, and 4-fermion interactions---will powerfully discriminate among these models. This information will be important in conjunction with new LHC data, or alone, if the new particles accompanying the 750 GeV resonance are beyond the mass reach of the LHC. (2) Over a longer term, the energy upgrade of the ILC to 1 TeV already discussed in the ILC TDR will enable experiments in gamma-gamma and e+e- collisions to directly produce and study the 750 GeV particle from these unique initial states.

preprint2016arXiv

Naturalness and light higgsinos: A powerful reason to build the ILC

A core prediction of natural Supersymmetry is the existence of four light higgsinos not too far above the mass of the $Z$ boson. The small mass splittings amongst the higgsinos -- typically 5-20\,GeV -- imply very little visible energy release from decays of heavier higgsinos. In particular, if other SUSY particles are quite heavy, as can be the case in SUSY with radiatively-driven naturalness, the higgsinos are extremely hard to detect at hadron colliders. The clean environment of electron-positron colliders with $\sqrt{s} > 2m_{\mathrm{higgsino}}$, however, would allow for a decisive search for the required light higgsinos. Thus, $e^+e^-$ colliders should either discover or exclude natural SUSY. We present a detailed study of higgsino pair production at the proposed International Linear $e^+e^-$ Collider which is under consideration for construction in Japan. A variety of precision measurements should allow for extraction of underlying parameters and provide a window onto physics at the grand unified scale.

preprint2015arXiv

A Calibration System for Compton Polarimetry at $e^+e^-$ Linear Colliders

Polarimetry with permille-level precision is essential for future electron-positron linear colliders. Compton polarimeters can reach negligible statistical uncertainties within seconds of measurement time. The dominating systematic uncertainties originate from the response and alignment of the detector which records the Compton scattered electrons. The robust baseline technology for the Compton polarimeters foreseen at future linear colliders is based on an array of gas Cherenkov detectors read out by photomultipliers. In this paper, we will present a calibration method which promises to monitor nonlinearities in the response of such a detector at the level of a few permille. This method has been implemented in an LED-based calibration system which matches the existing prototype detector. The performance of this calibration system is sufficient to control the corresponding contribution to the total uncertainty on the extracted polarisation to better than $0.1\%$.

preprint2015arXiv

A Quartz Cherenkov Detector for Compton-Polarimetry at Future e+e- Colliders

Precision polarimetry is essential for future e+ e- colliders and requires Compton polarimeters designed for negligible statistical uncertainties. In this paper, we discuss the design and construction of a quartz Cherenkov detector for such Compton polarimeters. The detector concept has been developed with regard to the main systematic uncertainties of the polarisation measurements, namely the linearity of the detector response and detector alignment. Simulation studies presented here imply that the light yield reachable by using quartz as Cherenkov medium allows to resolve in the Cherenkov photon spectra individual peaks corresponding to different numbers of Compton electrons. The benefits of the application of a detector with such single-peak resolution to the polarisation measurement are shown for the example of the upstream polarimeters foreseen at the International Linear Collider. Results of a first testbeam campaign with a four-channel prototype confirming simulation predictions for single electrons are presented.

preprint2014arXiv

Bilinear R Parity Violation at the ILC - Neutrino Physics at Colliders

Supersymmetry (SUSY) with bilinearly broken R parity (bRPV) offers an attractive possibility to explain the origin of neutrino masses and mixings. In such scenarios, the study of neutralino decays at colliders gives access to neutrino sector parameters. The ILC offers a very clean environment to study the neutralino properties as well as its subsequent decays, which typically involve a $W$ or $Z$ boson and a lepton. This study is based on ILC beam parameters according to the Technical Design Report for a center of mass energy of $500\,\mathrm{GeV}$. A full detector simulation of the International Large Detector (ILD) was performed for all Standard Model backgrounds and for $\widetildeχ_1^0$-pair production within a simplified model. The bRPV parameters are fixed according to current neutrino data. In this scenario, the $\widetildeχ_1^0$ mass can be reconstructed with an uncertainty of $δm = (40(\text{stat.}) + 50(\text{syst.}))\,\mathrm{MeV}$ for an integrated luminosity of $500\,\mathrm{fb}^{-1}$ from direct $\widetildeχ_1^0$-pair production, thus, to a large extent independently of the rest of the SUSY spectrum. The achievable precision on the atmospheric neutrino mixing angle $\sin^2 θ_{23}$ from measuring the neutralino branching fractions $\mathrm{BR}(\widetildeχ_1^0 \rightarrow W μ)$ and $\mathrm{BR}(\widetildeχ_1^0 \rightarrow W τ)$ at the ILC is better than current uncertainties from neutrino experiments. Thus, the ILC could have the opportunity to unveil the mechanism of neutrino mass generation.

preprint2014arXiv

Model Independent Determination of $HWW$ coupling and Higgs total width at ILC

This article is based on the talk presented at the International Workshop on Future Linear Colliders (LCWS13) which held during November 11-15, 2013 at Tokyo, Japan. We present several analyses related to the Higgs total width study at ILC based on the full detector simulation of ILD, which are \eevvH followed by \Htobb and \HtoWW. The studies show that at $\unit{250}{GeV}$ we can determine the Higgs total width with a relative precision of 11% and the $HWW$ coupling with 4.8%, whereas at $\unit{500}{GeV}$ the expected precision can be significantly improved to 5% and 1.2% respectively, assuming the baseline integrated luminosities of ILC, which are $\unit{250}{fb^{-1}}$ @ $\unit{250}{GeV}$, $\unit{500}{fb^{-1}}$ @ $\unit{500}{GeV}$, and a beam polarization of $P(e^{-},e^{+})=(-80%,+30%)$. A new approach of removing pile-up particles based on multivariate method developed during those analyses is also presented.

preprint2014arXiv

Spin Transport and Polarimetry in the Beam Delivery System of the International Linear Collider

Polarised electron and positron beams are key ingredients to the physics programme of future linear colliders. Due to the chiral nature of weak interactions in the Standard Model - and possibly beyond - the knowledge of the luminosity-weighted average beam polarisation at the $e^+e^-$ interaction point is of similar importance as the knowledge of the luminosity and has to be controlled to permille-level precision in order to fully exploit the physics potential. The current concept to reach this challenging goal combines measurements from Laser-Compton polarimeters before and after the interaction point with measurements at the interaction point. A key element for this enterprise is the understanding of spin-transport effects between the polarimeters and the interaction point as well as collision effects. We show that without collisions, the polarimeters can be cross-calibrated to 0.1 %, and we discuss in detail the impact of collision effects and beam parameters on the polarisation value relevant for the interpretation of the $e^+e^-$ collision data.

preprint2013arXiv

Electroweakino Searches: A Comparative Study for LHC and ILC (A Snowmass White Paper)

We make a systematic and comparative study for the LHC and ILC for the electroweakino searches in the Minimal Supersymmetric Standard Model. We adopt a general bottom-up approach and scan over the parameter regions for all the three cases of the lightest supersymmetric particle being Bino-, Wino-, and Higgsino-like. The electroweakino signal from pair production and subsequent decay to Wh (h to b\bar b) final state may yield a sensitivity of 95% C.L. exclusion (5sigma discovery) to the mass scale M_2, mu ~ 250-400 GeV (200-250 GeV) at the 14 TeV LHC with an luminosity of 300 fb^{-1}. Combining with all the other decay channels, the 95% C.L. exclusion (5sigma discovery) may be extended to M_2, mu ~ 480-700 GeV (320-500 GeV). At the ILC, the electroweakinos could be readily discovered once the kinematical threshold is crossed, and their properties could be thoroughly studied.

preprint2013arXiv

Physics Case for the ILC Project: Perspective from Beyond the Standard Model

The International Linear Collider (ILC) has recently proven its technical maturity with the publication of a Technical Design Report, and there is a strong interest in Japan to host such a machine. We summarize key aspects of the Beyond the Standard Model physics case for the ILC in this contribution to the US High Energy Physics strategy process. On top of the strong guaranteed physics case in the detailed exploration of the recently discovered Higgs boson, the top quark and electroweak precision measurements, the ILC will offer unique opportunities which are complementary to the LHC program of the next decade. Many of these opportunities have connections to the Cosmic and Intensity Frontiers, which we comment on in detail. We illustrate the general picture with examples of how our world could turn out to be and what the ILC would contribute in these cases, with an emphasis on value-added beyond the LHC. These comprise examples from Supersymmetry including light Higgsinos, a comprehensive bottom-up coverage of NLSP-LSP combinations for slepton, squark, chargino and neutralino NLSP, a stau-coannihilation dark matter scenario and bilinear R-parity violation as explanation for neutrino masses and mixing, as well as generic WIMP searches and Little Higgs models as non-SUSY examples.

preprint2013arXiv

Post LHC8 SUSY benchmark points for ILC physics

We re-evaluate prospects for supersymmetry at the proposed International Linear e^+e^- Collider (ILC) in light of the first two years of serious data taking at LHC: LHC7 with ~5 fb^{-1} of pp collisions at sqrt{s}=7 TeV and LHC8 with ~20 fb^{-1} at \sqrt{s}=8 TeV. Strong new limits from LHC8 SUSY searches, along with the discovery of a Higgs boson with m_h~125 GeV, suggest a paradigm shift from previously popular models to ones with new and compelling signatures. After a review of the current status of supersymmetry, we present a variety of new ILC benchmark models, including: natural SUSY, radiatively-driven natural SUSY (RNS), NUHM2 with low m_A, a focus point case from mSUGRA/CMSSM, non-universal gaugino mass (NUGM) model, stau-coannihilation, Kallosh-Linde/spread SUSY model, mixed gauge-gravity mediation, normal scalar mass hierarchy (NMH), and one example with the recently discovered Higgs boson being the heavy CP-even state H. While all these models at present elude the latest LHC8 limits, they do offer intriguing case study possibilities for ILC operating at \sqrt{s}~0.25-1 TeV. The benchmark points also present a view of the widely diverse SUSY phenomena which might still be expected in the post LHC8 era at both LHC and ILC.

preprint2013arXiv

Tackling light higgsinos at the ILC

In supersymmetric extensions of the Standard Model, higgsino-like charginos and neutralinos are preferred to have masses of the order of the electroweak scale by naturalness arguments. Such light $\widetildeχ^0_1$, $\widetildeχ^0_2$ and $\widetildeχ^{\pm}_1$ states can be almost mass degenerate, and their decays are then difficult to observe at colliders. In addition to the generic naturalness argument, light higgsinos are well motivated from a top-down perspective. For instance, they arise naturally in certain models of hybrid gauge-gravity mediation. In the present analysis, we study two benchmark points which have been derived in the framework of such a model, which exhibit mass differences of O(GeV) in the higgsino sector. For chargino pair and neutralino associated production with initial-state photon radiation, we simulate the detector response and determine how accurately the small mass differences, the absolute masses and the cross sections can be measured at the International Linear Collider. Assuming that 500/fb has been collected at each of two beam-polarisations $P(e^+,e^-)=(\pm 30\%,\mp 80\%)$, we find that the mass differences can be measured to 40-300 MeV, the cross sections to 2-5%, and the absolute masses to 1.5-3.3 GeV, where the range of values correspond to the different scenarios and channels. Based on these observables we perform a parameter fit in the MSSM, from which we infer that the higgsino mass parameter $μ$ can be measured to a precision of about $Δμ=$2--7 GeV. For the electroweak gaugino mass parameters $M_1$, $M_2$, which are chosen in the multi-TeV range, a narrow region is compatible with the measurements. For both parameters independently, we can determine a lower bound.

preprint2013arXiv

The International Linear Collider Technical Design Report - Volume 2: Physics

The International Linear Collider Technical Design Report (TDR) describes in four volumes the physics case and the design of a 500 GeV centre-of-mass energy linear electron-positron collider based on superconducting radio-frequency technology using Niobium cavities as the accelerating structures. The accelerator can be extended to 1 TeV and also run as a Higgs factory at around 250 GeV and on the Z0 pole. A comprehensive value estimate of the accelerator is give, together with associated uncertainties. It is shown that no significant technical issues remain to be solved. Once a site is selected and the necessary site-dependent engineering is carried out, construction can begin immediately. The TDR also gives baseline documentation for two high-performance detectors that can share the ILC luminosity by being moved into and out of the beam line in a "push-pull" configuration. These detectors, ILD and SiD, are described in detail. They form the basis for a world-class experimental programme that promises to increase significantly our understanding of the fundamental processes that govern the evolution of the Universe.

preprint2012arXiv

Characterising WIMPs at a future $e^+e^-$ Linear Collider

We investigate the prospects for detecting and measuring the parameters of WIMP dark matter in a model independent way at the International Linear Collider. The signal under study is direct WIMP pair production with associated initial state radiation $e^+e^- \rightarrow χχγ$. The analysis accounts for the beam energy spectrum of the ILC and the dominant machine induced backgrounds. The influence of the detector parameters are incorporated by full simulation and event reconstruction within the framework of the ILD detector concept. We show that by using polarised beams, the detection potential is significantly increased by reduction of the dominant SM background of radiative neutrino production $e^+e^- \rightarrow ννγ$. The dominant sources of systematic uncertainty are the precision of the polarisation measurement and the shape of the beam energy spectrum. With an integrated luminosity of 500 fb the helicity structure of the interaction involved can be inferred, and the masses and cross-sections can be measured with a relative accuracy of the order of 1 %.

preprint2012arXiv

Measurement of radiative neutralino production

We perform the first experimental study with full detector simulation for the radiative production of neutralinos at the linear collider, at sqrt{s} = 500 GeV and realistic beam polarizations. We consider all relevant backgrounds, like the Standard Model background from radiative neutrino production. The longitudinal polarized beams enhance the signal and simultaneously reduce the background, such that statistical errors are significantly reduced. We find that the photon spectrum from the signal process can be well isolated. The neutralino mass and the cross section can be measured at a few per-cent level, with the largest systematic uncertainties from the measurement of the beam polarization and the beam energy spectrum.

preprint2012arXiv

Model-independent WIMP Characterisation using ISR

The prospects of measuring the parameters of WIMP dark matter in a model independent way at the International Linear Collider are investigated. The signal under study is direct WIMP pair production with associated initial state radiation. The analysis is performed in full simulation of the ILD detector concept. With an integrated luminosity of L = 500 fb-1 and realistic beam polarizations the helicity structure of the WIMP couplings to electrons can be determined, and the masses and cross sections can be measured to the percent level. The systematic uncertainties are dominated by the polarization measurement and the luminosity spectrum.

preprint2012arXiv

Post LHC7 SUSY benchmark points for ILC physics

We re-evaluate prospects for supersymmetry at the proposed International Linear $e^+e^-$ Collider (ILC) in light of the first year of serious data taking at LHC with $\sqrt{s}=7$ TeV and $\sim 5$ fb$^{-1}$ of $pp$ collisions (LHC7). Strong new limits from LHC SUSY searches, along with a hint of a Higgs boson signal around $m_h\sim 125$ GeV, suggest a paradigm shift from previously popular models to ones with new and compelling signatures. We present a variety of new ILC benchmark models, including: natural SUSY, hidden SUSY, NUHM2 with low $m_A$, non-universal gaugino mass (NUGM) model, pMSSM, Kallosh-Linde model, Brümmer-Buchmüller model, normal scalar mass hierarchy (NMH) plus one surviving case from mSUGRA/CMSSM in the far focus point region. While all these models at present elude the latest LHC limits, they do offer intriguing case study possibilities for ILC operating at $\sqrt{s}\sim 0.25-1$ TeV, and present a view of some of the diverse SUSY phenomena which might be expected at both LHC and ILC in the post LHC7 era.

preprint2011arXiv

Design and Construction of a Cherenkov Detector for Compton Polarimetry at the ILC

This paper describes the design and construction of a Cherenkov detector conceived with regard to high energy Compton polarimeters for the International Linear Collider, where beam diagnostic systems of unprecedented precision must complement the interaction region detectors to pursue an ambitious physics programme. Besides the design of a prototype Cherenkov detector, detailed simulation studies are presented. Results of a first testbeam campaign with the main objective of validating the simulation in terms of the light distribution inside the channels and the channel response are presented. Furthermore, a new method for aligning the detector without the need of dedicated data taking has been developped.

preprint2010arXiv

Cherenkov Detector Prototype & Testbeam 2009

Precise knowledge of all beam parameters is crucial to fully exploit the physics potential of the International Linear Collider (ILC). A sufficiently accurate measurement of the beam polarisation can only be achieved using dedicated high energy Compton polarimeters combined with well-designed arrays of Cherenkov detectors. This note focuses on the design and detailed simulation of a suitable Cherenkov detector prototype and provides an overview of first results from a highly successful beam test period.

preprint2010arXiv

Consideration of Photon Radiation in Kinematic Fits for Future e+ e- Colliders

Kinematic fitting is an important tool to improve the resolution in high-energy physics experiments. At future e+e- colliders, photon radiation parallel to the beam carrying away large amounts of energy and momentum will become a challenge for kinematic fitting. A photon with longitudinal momentum pz(η) is introduced, which is parametrized such that η follows a normal distribution. In the fit, η is treated as having a measured value of zero, which corresponds to pz = 0. As a result, fits with constraints on energy and momentum conservation converge well even in the presence of a highly energetic photon, while the resolution of fits without such a photon is retained. A fully simulated and reconstructed e+e- -> qqqq event sample at sqrt(s) = 500 GeV is used to investigate the performance of this method under realistic conditions, as expected at the International Linear Collider.

preprint2010arXiv

Model independent WIMP Searches in full Simulation of the ILD Detector

In this study the ILC's capabilities for detecting WIMPs and measure their properties are investigated. The signal events are detected by associated production of Initial State Radiation (ISR). A model independent formulation of the signal cross section is used. The cross section is normalized by inference from the observed abundance of cosmological Dark Matter (DM). The study is performed in full simulation of the ILD00 detector model. The prospects of determining the WIMP parameters individually and simultaneously are presented.

preprint2010arXiv

New ALPS Results on Hidden-Sector Lightweights

The ALPS collaboration runs a "Light Shining through a Wall" (LSW) experiment to search for photon oscillations into "Weakly Interacting Sub-eV Particles" (WISPs) often predicted by extensions of the Standard Model. The experiment is set up around a superconducting HERA dipole magnet at the site of DESY. Due to several upgrades of the experiment we are able to place limits on the probability of photon-WISP-photon conversions of a few 10^{-25}. These limits result in today's most stringent laboratory constraints on the existence of low mass axion-like particles, hidden photons and minicharged particles.

preprint2010arXiv

Prospects for the study of the \stau-system in SPS1a' at the ILC

The prospects for the analysis of tau channels at the SUSY benchmark point SPS1a', especially from e+e- -> stau_1 stau_1 and e+e- -> stau_2 stau_2, have been studied in full simulation of the ILD detector concept forseen for the International Linear Collider. All accessible SUSY channels as well as all Standard Model backgrounds were generated at a centre-of-mass energy E_CMS=500 GeV, including the beam energy spectrum and beam backgrounds expected for nominal ILC beam parameters. With an integrated luminosity of 500 fb-1 delivered to the experiment, the masses of the stau_1 and stau_2 can be measured to 107.69^{+0.03}_{-0.06} GeV +- 1.1 δM_LSP and 183 ^{+11}_{-5} GeV +- 18 δM_LSP, respectively, while the true values in SPS1a' are 107.9 GeV and 194.9 GeV, respectively. The cross sections for stau_1 and stau_2 pair production could be obtained with a precision of 3.1% and 4.2%, respectively. Combining the mass and cross section measurement in the stau_2 channel allows to determine the LSP mass with a relative error of 1.7%, assuming a known mixing angle. In stau_1 -> tau LSP decays, the tau polarisation is measured to be 91 +- 9% and 87.0 +- 3.4% in the pi and rho decay channels of the tau, respectively. The true value in the simulated SPS1a' sample is 89.6%.

preprint2010arXiv

Treatment of Photon Radiation in Kinematic Fits at Future e+ e- Colliders

Kinematic fitting, where constraints such as energy and momentum conservation are imposed on measured four-vectors of jets and leptons, is an important tool to improve the resolution in high-energy physics experiments. At future e+ e- colliders, photon radiation parallel to the beam carrying away large amounts of energy and momentum will become a challenge for kinematic fitting. A photon with longitudinal momentum p_z^γ(η) is introduced, which is parametrized such that η~follows a normal distribution. In the fit, η~is treated as having a measured value of zero, which corresponds to p_z^γ(η)=0. As a result, fits with constraints on energy and momentum conservation converge well even in the presence of a highly energetic photon, while the resolution of fits without such a photon is retained. A fully simulated and reconstructed e+ e- -> qqqq event sample at \sqrt{s}=500 GeV is used to investigate the performance of this method under realistic conditions, as expected at the International Linear Collider.

preprint2009arXiv

Precision Polarimetry at the ILC: Concepts, Simulations and experiments

The precision physics program of the ILC requires precise knowledge of the state of beam polarisation. In fact the Compton polarimeters intended for the ILC will have to measure the polarisation with error a factor of 2 smaller than the previous best measurement at the SLAC SLD experiment. In order to further reduce measurement error, spin tracking simulations in the ILC Beam Delivery System subject to ground motion induced misalignment have been performed and the expected variation in polarisation has been quantified. A prototype of a high precision spectrometer to record Compton scattered electrons from the interaction of a longitudinal laser and the charged beams has been developed. The Compton electrons interact with a gas in the polarimeter channels to produce Cherenkov radiation measured by photodetectors. The calibration of the photodetectors is crucial and exhaustive bench tests of the photodetector linearity have been performed. The polarimeter prototype itself will be tested at the ELSA testbeam in Bonn in Spring 2009.

preprint2009arXiv

Resonant laser power build-up in ALPS -- a "light-shining-through-walls" experiment

The ALPS collaboration runs a light-shining-through-walls (LSW) experiment to search for photon oscillations into "weakly interacting sub-eV particles" (WISPs) inside of a superconducting HERA dipole magnet at the site of DESY. In this paper we report on the first successful integration of a large-scale optical cavity to boost the available power for WISP production in this type of experiments. The key elements are a frequency tunable narrow line-width continuous wave laser acting as the primary light source and an electronic feed-back control loop to stabilize the power build-up. We describe and characterize our apparatus and demonstrate the data analysis procedures on the basis of a brief exemplary run.