Researcher profile

Ben T. McAllister

Ben T. McAllister contributes to research discovery and scholarly infrastructure.

ResearcherAffiliation not importedOpen to collaborate

Trust snapshot

Quick read

Trust 19 - UnverifiedVerification L1Unclaimed author
5works
0followers
5topics
4close collaborators

Actions

Decide how to stay connected

Follow researcher0

Identity and collaboration

How to connect with this researcher

Claiming links this public author record to a researcher profile and unlocks direct collaboration workflows.

Log in to claim

Direct collaboration

Open a focused conversation when the fit is right

Claim this author entity first to unlock direct invitations.

Research graph

See the researcher in context

Open full explorer

Inspect adjacent work, topics, institutions and collaborators without jumping out to a separate graph page.

Building this graph slice

BZPEER is loading the nearby papers, people, topics and institutions for this page.

Published work

5 published item(s)

preprint2022arXiv

Direct Search for Dark Matter Axions Excluding ALP Cogenesis in the 63-67 micro-eV Range, with The ORGAN Experiment

The standard model axion seesaw Higgs portal inflation (SMASH) model is a well motivated, self-contained description of particle physics over a range of energy scales that predicts axion dark matter particles to exist within the mass range of $50-200\,μ$eV. To scan these masses an axion haloscope under a strong constant magnetic field must operate between 12 to 48 GHz. The ORGAN experiment (situated in Perth, Australia) is a microwave cavity axion haloscope that aims to search the majority of the mass range predicted by the SMASH model. Here we present results of Phase 1a, the first experiment to scan and search for axions in the microwave Ku Band. Our initial scan sets a new limit on the coupling of axions to two photons of $g_{aγγ}\geq 3\times 10^{-12}\, \textrm{GeV}^{-1}$ over the mass range $63.2$ to $67.1~μ$eV with $95\%$ confidence. This result is the most sensitive to date in this mass range, sufficient to exclude the well motivated ALP (Axion Like Particle) cogenesis model for dark matter, which adds ALPs to the standard model in the early universe to simultaneously explain the observed baryon and dark matter densities. To attain this level of sensitivity we utilised a TM$_{010}$ cylindrical cavity resonator, scanned between 15.28 to 16.23 GHz through the utilisation of a tuning rod. Measurements were performed over a duration of 3.5 weeks with a $74\%$ duty cycle, with the resonator coupled to a low noise HEMT amplifier and placed inside a superconducting solenoidal electromagnet of 11.5 Tesla in magnetic field strength.

preprint2021arXiv

Searching for dark matter with an unequal delay interferometer

We propose a new type of experiment that compares the frequency of a clock (an ultra-stable optical cavity in this case) at time $t$ to its own frequency some time $t-T$ earlier, by "storing" the output signal (photons) in a fibre delay line. In ultra-light oscillating dark matter (DM) models, such an experiment is sensitive to coupling of DM to the standard model fields, through oscillations of the cavity and fibre lengths and of the fibre refractive index. Additionally, the sensitivity is significantly enhanced around the mechanical resonances of the cavity. We present experimental result of such an experiment and report no evidence of DM for masses in the [$4.1\times 10^{-11}$, $8.3\times 10^{-10}$]~eV region. In addition, we improve constraints on the involved coupling constants by one order of magnitude in a standard galactic DM model, at the mass corresponding to the resonant frequency of our cavity. Furthermore, in the model of relaxion DM, we improve on existing constraints over the whole DM mass range by about one order of magnitude, and up to six orders of magnitude at resonance.

preprint2021arXiv

The Electrodynamics of Free and Bound Charge Electricity Generators using Impressed Sources and the Modification to Maxwell's Equations

The conversion of external energy into electricity is the foundation of power station and energy harvesting operation. The external source supplies an impressed force per unit charge to free or bound charge to produces AC electricity. We analyze the electrodynamics of ideal electricity generators through a time dependent permanent polarization without any applied electric field, which modifies the constitutive relations and is essential to oscillate charge in a lossless way. For both cases, we show that Maxwell's equations, and in particular Faraday's law are modified, along with the required boundary conditions through the addition of an effective impressed magnetic current boundary source. For the free charge case, we highlight the example of an electromagnetic generator based on Lorentz force, where the impressed force per unit charge that polarizes the conductor comes from mechanical motion of free charge with an impressed velocity of a conductor relative to a stationary DC magnetic field. The bound charge generator is an idealized permanently polarized bar electret with a time dependent permanent polarization, the underlying principle behind piezoelectric nano-generators. In the open circuit state, both electricity generators are equivalent to idealized Hertzian dipoles, with the open circuit voltage equal to the induced emf. Analyzing the short circuit responses, we show that the bound charge electricity generator has a capacitive source impedance. In contrast, we show for the ideal free charge AC electricity generator, the back emf from the inductance of the loop that defines the short circuit, directly cancels the source emf, so the voltage across the inductor is solely determined by the magnetic current boundary source. Thus, we determine the magnetic current boundary source is the topological invariant that best describes the output voltage of an AC generator.

preprint2020arXiv

Broadband Electrical Action Sensing Techniques with conducting wires for low-mass dark matter axion detection

Due to the inverse Primakoff effect it has been shown that when axions interact with a DC magnetic B-field the resulting electrical action will produce an AC electromotive force which oscillates at the Compton frequency of the axion, and may be modeled as an oscillating effective impressed magnetic current boundary source. We use this result to calculate the sensitivity of new experiments to low-mass axions using the quasi-static technique. First, we calculate the current induced in an electric dipole antenna (straight conducting wire) when the DC B-field is spatially constant and show that it has a sensitivity proportional to the axion mass. Following this we extend the topology by making use of the full extent of the spatially varying DC B-field. This extension is achieved by transforming the 1D conducting wire to a 2D winding, to fully link the effective magnetic current boundary source and thus couple to the full axion induced electrical action. In this case the conductor becomes a coil winding where the voltage induced across the winding increases proportionally to the number of windings. We investigate two different topologies: The 1st uses a single winding, and couples to the effective short circuit current generated in the winding, which is read out using a sensitive low impedance SQUID amplifier: The 2nd uses multiple windings, with every turn effectively increasing the the voltage output proportional to the winding number. The read out of this configuration is optimised by implementing a cryogenic low-noise high input impedance voltage amplifier. The end result is a new Broadband Electrical Action Sensing Techniques with orders of magnitude improved sensitivity, which is linearly proportional to the axion photon coupling and capable of detecting QCD dark matter axions.

preprint2017arXiv

The ORGAN Experiment: An axion haloscope above 15 GHz

We present first results and future plans for the Oscillating Resonant Group AxioN (ORGAN) experiment, a microwave cavity axion haloscope situated in Perth, Western Australia designed to probe for high mass axions motivated by several theoretical models. The first stage focuses around 26.6 GHz in order to directly test a claimed result, which suggests axions exist at the corresponding mass of $110~μ$eV. Later stages will move to a wider scan range of 15-50 GHz ($60-210~μ$eV). We present the results of the pathfinding run, which sets a limit on $g_{aγγ}$ of $2.02\times 10^{-12} $eV$^{-1}$ at 26.531 GHz, or 110~$μ$eV, in a span of 2.5 neV (shaped by the Lorentzian resonance) with $90 \%$ confidence. Furthermore, we outline the current design and future strategies to eventually attain the sensitivity to search for well known axion models over the wider mass range.