Researcher profile

B. Qi

B. Qi contributes to research discovery and scholarly infrastructure.

ResearcherAffiliation not importedOpen to collaborate

Trust snapshot

Quick read

Trust 21 - EmergingVerification L1Unclaimed author
6works
0followers
3topics
4close collaborators

Actions

Decide how to stay connected

Follow researcher0

Identity and collaboration

How to connect with this researcher

Claiming links this public author record to a researcher profile and unlocks direct collaboration workflows.

Log in to claim

Direct collaboration

Open a focused conversation when the fit is right

Claim this author entity first to unlock direct invitations.

Research graph

See the researcher in context

Open full explorer

Inspect adjacent work, topics, institutions and collaborators without jumping out to a separate graph page.

Building this graph slice

BZPEER is loading the nearby papers, people, topics and institutions for this page.

Published work

6 published item(s)

preprint2022arXiv

Exploring the intrinsic energy resolution of liquid scintillator to approximately 1 MeV electrons

We proposed a novel method for exploring the intrinsic energy resolution of a liquid scintillator (LAB + 2.5 g/L PPO + 3 mg/L bis-MSB) for approximately 1 MeV electrons. With the help of coincidence detection technology, single-energy electrons of Bi 207 were effectively selected. With careful measurement and analysis of the energy resolution of a small liquid scintillator detector, the intrinsic energy resolution to 976 keV electrons was extracted to be 1.83%. We used the wide-angle Compton coincidence (WACC) method to measure the luminescent nonlinearity of the liquid scintillator and found that it contributes only weakly to the intrinsic energy resolution of electrons. Such an unexpected large intrinsic energy resolution may come from fluctuations in energy transfer processes.

preprint2022arXiv

Scintillator Tile Batch Test of CEPC AHCAL

Hadron calorimeter (HCAL) is an essential sub-detector of the baseline detector system for Circular Electron Positron Collider (CEPC). We plan to build an Analog Hadron CALorimeter (AHCAL) prototype based on the Particle Flow Algorithm (PFA). The AHCAL of CEPC uses steel as absorber and scintillator tiles read out by Silicon Photo-Multipliers (SiPMs) as sensitive medium. The energy linearity and resolution of the calorimeter depends on the light yield uniformity of sensitive medium. It is essential to qualify the entire detector production in order to select scintillator tiles with light yield uniform within 10\%. An automated batch test platform has been designed with 144 channels, an automated 3D servo motor. The paper summarizes the tests performed on more than 15000 scintillator tiles. The measured light yield, corrected for the set-up response non-uniformity, is around 12.9 p.e. . About 91.6\% of scintillators (14219 pieces) are qualified within 10\% of light yield window.

preprint2021arXiv

Timing performance of a multi-pad PICOSEC-Micromegas detector prototype

The multi-pad PICOSEC-Micromegas is an improved detector prototype with a segmented anode, consisting of 19 hexagonal pads. Detailed studies are performed with data collected in a muon beam over four representative pads. We demonstrate that such a device, scalable to a larger area, provides excellent time resolution and detection efficiency. As expected from earlier single-cell device studies, we measure a time resolution of approximately 25 picoseconds for charged particles hitting near the anode pad centers, and up to 30 picoseconds at the pad edges. Here, we study in detail the effect of drift gap thickness non-uniformity on the timing performance and evaluate impact position based corrections to obtain a uniform timing response over the full detector coverage.

preprint2020arXiv

Beam test results of IHEP-NDL Low Gain Avalanche Detectors(LGAD)

To meet the timing resolution requirement of up-coming High Luminosity LHC (HL-LHC), a new detector based on the Low-Gain Avalanche Detector(LGAD), High-Granularity Timing Detector (HGTD), is under intensive research in ATLAS. Two types of IHEP-NDL LGADs(BV60 and BV170) for this update is being developed by Institute of High Energy Physics (IHEP) of Chinese Academic of Sciences (CAS) cooperated with Novel Device Laboratory (NDL) of Beijing Normal University and they are now under detailed study. These detectors are tested with $5GeV$ electron beam at DESY. A SiPM detector is chosen as a reference detector to get the timing resolution of LGADs. The fluctuation of time difference between LGAD and SiPM is extracted by fitting with a Gaussian function. Constant fraction discriminator (CFD) method is used to mitigate the effect of time walk. The timing resolution of $41 \pm 1 ps$ and $63 \pm 1 ps$ are obtained for BV60 and BV170 respectively.

preprint2020arXiv

Experimental and theoretical study of electronic and hyperfine properties of hydrogenated anatase (TiO$_2$): defects interplay and thermal stability

In this study we report on the results from emission $^{57}$Fe M${ö}$ssbauer Spectroscopy experiments, using dilute $^{57}$Mn implantation into pristine (TiO$_2$) and hydrogenated anatase held at temperatures between 300-700 K. Results of the electronic structure and local environment are complemented with ab-initio calculations. Upon implantation both Fe$^{2+}$ and Fe$^{3+}$ are observed in pristine anatase, where the latter demonstrates the spin-lattice relaxation. The spectra obtained for hydrogenated anatase show no Fe$^{3+}$ contribution, suggesting that hydrogen acts as a donor. Due to the low threshold, hydrogen diffuses out of the lattice. Thus showing a dynamic behavior on the time scale of the $^{57}$Fe 14.4 keV state. The surrounding oxygen vacancies favor the high-spin Fe$^{2+}$ state. The sample treated at room temperature shows two distinct processes of hydrogen motion. The motion commences with the interstitial hydrogen, followed by switching to the covalently bound state. Hydrogen out-diffusion is hindered by bulk defects, which could cause both processes to overlap. Supplementary UV-Vis and electrical conductivity measurements show an improved electrical conductivity and higher optical absorption after the hydrogenation. X-ray photoelectron spectroscopy at room temperature reveals that the sample hydrogenated at 573 K shows presence of both Ti$^{3+}$ and Ti$^{2+}$ states. This could imply that a significant amount of oxygen vacancies and -OH bonds are present in the samples. Theory suggests that in the anatase sample implanted with Mn(Fe), probes were located near equatorial vacancies as next-nearest-neighbours, whilst a metastable hydrogen configuration is responsible for the annealing behavior.

preprint2020arXiv

Radiation Campaign of HPK Prototype LGAD sensors for the High-Granularity Timing Detector (HGTD)

We report on the results of a radiation campaign with neutrons and protons of Low Gain Avalanche Detectors (LGAD) produced by Hamamatsu (HPK) as prototypes for the High-Granularity Timing Detector (HGTD) in ATLAS. Sensors with an active thickness of 50~$μ$m were irradiated in steps of roughly 2$\times$ up to a fluence of $3\times10^{15}~\mathrm{n_{eq}cm^{-2}}$. As a function of the fluence, the collected charge and time resolution of the irradiated sensors will be reported for operation at $-30^{\circ}$.