Source author record

B. K. Wuenschek

Explore this author’s publications, collaborators and research topics. This catalog record has not been claimed by its author.

ResearcherUnclaimed source record

Catalog footprint

Research overview

2works
2topics
4close collaborators

Published work

2 publications

preprint2016arXiv

Structure near K−K^-+pp+pp threshold in the in-flight 3^3He(K−,Λp)n(K^-,Λp)n reaction

To search for an S= -1 di-baryonic state which decays to ΛpΛp, the 3He(K−,Λp)nmissing {\rm{}^3He}(K^-,Λp)n_{missing} reaction was studied at 1.0 GeV/cc. Unobserved neutrons were kinematically identified from the missing mass MXM_X of the 3He(K−,Λp)X {\rm{}^3He}(K^-,Λp)X reaction in order to have a large acceptance for the ΛpnΛpn final state. The observed ΛpnΛp n events, distributed widely over the kinematically allowed region of the Dalitz plot, establish that the major component comes from a three nucleon absorption process. A concentration of events at a specific neutron kinetic energy was observed in a region of low momentum transfer to the ΛpΛp. To account for the observed peak structure, the simplest S-wave pole was assumed to exist in the reaction channel, having Breit-Wigner form in energy and with a Gaussian form-factor. A minimum χ2χ^2 method was applied to deduce its mass MX =M_X\ = 2355 −8+6 ^{+ 6}_{ - 8} (stat.) ±12 \pm 12 (syst.) MeV/c2^2, and decay-width ΓX =Γ_X\ = 110 −17+19 ^{+ 19}_{ - 17} (stat.) ±27 \pm 27 (syst.) MeV/c2^2, respectively. The form factor parameter QX∼Q_X \sim 400 MeV/cc implies that the range of interaction is about 0.5

preprint2011arXiv

Temperature dependencies of the energy and time resolution of silicon drift detectors

The response of silicon drift detectors (SDDs), which were mounted together with their preamplifiers inside a vacuum chamber, was studied in a temperature range from 100 K to 200 K. In particular, the energy resolution could be stabilized to about 150 eV at 6 keV between 130 K and 200 K, while the time resolution shows a temperature dependence of T^3 in this temperature range. To keep a variation of the X-ray peak positions within 1 eV, it is necessary to operate the preamplifier within a stability of 1 K around 280 K. A detailed investigation of this temperature influences on SDDs and preamplifiers is presented.

Research graph

See the researcher in context

Open full explorer

Inspect adjacent papers, topics, institutions and collaborators without losing the researcher page.

Building this map preview

BZPEER is loading the nearby papers, people, topics and institutions for this page.