Researcher profile

B. Dubetsky

B. Dubetsky contributes to research discovery and scholarly infrastructure.

ResearcherAffiliation not importedOpen to collaborate

Trust snapshot

Quick read

Trust 21 - EmergingVerification L1Unclaimed author
7works
0followers
2topics
2close collaborators

Actions

Decide how to stay connected

Follow researcher0

Identity and collaboration

How to connect with this researcher

Claiming links this public author record to a researcher profile and unlocks direct collaboration workflows.

Log in to claim

Direct collaboration

Open a focused conversation when the fit is right

Claim this author entity first to unlock direct invitations.

Research graph

See the researcher in context

Open full explorer

Inspect adjacent work, topics, institutions and collaborators without jumping out to a separate graph page.

Building this graph slice

BZPEER is loading the nearby papers, people, topics and institutions for this page.

Published work

7 published item(s)

preprint2022arXiv

Local positioning system as a classic alternative to atomic navigation

A local positional system (LPS) is proposed, in which particles are launched at given velocities, and a sensor system measures the trajectory of particles in the platform frame. These measurements allow us to restore the position and orientation of the platform in the frame of the rotating Earth, without solving navigation equations. If there are also velocimeters installed on the platform, then one can restore the velocity and angular rate of the platform rotation in respect to the Earth. Instead of navigational equations, it is necessary to obtain the classical trajectory of a particle in the field of a rotating gravity source. Taking into account the gravity-gradient, Coriolis, and centrifugal forces, the exact expression for this trajectory is derived, which can be widely used in atomic interferometry. A new iterative method for restoring the orientation of the platform without using gyroscopes is proposed. The simulation allowed us to determine the conditions under which the LPS-navigation error per hour is about 10m.

preprint2021arXiv

Comment on New apparatus design for high-precision measurement of G with atom interferometry

It is shown that even in the case of a negligibly small change in the gradient of the gravitational field of the mass source in the axial direction, the dependence of this gradient in the radial direction leads to a systematic error in Newton gravitational constant value. The magnitude of this error is calculated for two configurations of the field. For both configurations it was found that this error is larger than the inaccuracy predicted in the article by M. Jain et al [Eur. Phys. J. D 75, 197 (2021)]. In addition, we found the geometry of the source mass, for which this systematic error disappears.

preprint2021arXiv

Newtonian gravitational constant measurement. All atomic variables become extreme when using a source mass consisting of 3 or more parts

Atomic interferometry methods used to measure the Newtonian gravitational constant. To improve the accuracy, one should measure the phase of an atomic interferometer at extreme values of atomic vertical velocities and coordinates. Owing to symmetry, the horizontal components of atomic velocities and coordinates are also extreme. We propose using a source mass consisting of 3 or more parts, since only in this case one can find such an arrangement of parts that all atomic variables become extreme. Nonlinear dependences of the phase on the uncertainties of atomic positions and velocities near those extreme values required us to modify the expression for the phase relative standard deviation (RSD). Moreover, taking into account nonlinear terms in the phase dependence on the atomic coordinates and velocities leads to a phase shift. In the last experiment to measure the Newtonian gravitational constant by atomic interferometry, this shift was not included. We took the shift into account, got a value of 199ppm for it, and this leads to a decrease in the value of the Newton constant by 0.02%. In addition, we showed that at equal sizes of the atomic cloud in the vertical and horizontal directions, as well as at equal atomic vertical and transverse temperatures, systematic errors due to the finite size and temperature of the cloud disappear. The calculation also showed that when using the 13-ton source mass proposed recently, the measurement accuracy can reach 17ppm for a source mass consisting of 4 quarters. We assumed that the source mass consisting of a set of cylinders is used for measurements. We have obtained a new analytical expression for the gravitational field of a homogeneous cylinder.

preprint2020arXiv

Optimization of the atom interferometer phase produced by the set of cylindrical source masses to measure the Newtonian gravity constant

An analytical expression for the gravitational field of a homogeneous cylinder is derived. The phase of the atom interferometer produced by the gravity field of the set of cylinders has been calculated. The optimal values of the initial positions and velocities of atomic clouds were obtained. It is shown that at equal sizes of the atomic cloud in the vertical and transverse directions, as well as at equal atomic vertical and transverse temperatures, systematic errors due to the finite size and temperature of the cloud disappear. To overcome the influence of the Earth gravitational field on the accuracy of the phase double difference measurement, it is proposed to use the technique of eliminating gravity-gradient terms. After eliminating, one can use extreme values of the atomic positions and velocities. Nonlinear dependences of the phase on the uncertainties of atomic positions and velocities near those extreme values required us to modify the expression for the standard phase deviation. Moreover, such dependences lead to a phase shift, which was also calculated. The relative accuracy of measurements of Newtonian gravitational constant 10^-4 and 2*10^-5 is predicted for sets of 24 and 630 cylinders, respectively.

preprint2016arXiv

Atom interferometry in the presence of an external test mass

The influence of an external test mass on the phase of the signal of an atom interferometer is studied theoretically. Using traditional techniques in atom optics based on the density matrix equations in the Wigner representation, we are able to extract the various contributions to the phase of the signal associated with the classical motion of the atoms, the quantum correction to this motion resulting from atomic recoil that is produced when the atoms interact with Raman field pulses, and quantum corrections to the atomic motion that occur in the time between the Raman field pulses. By increasing the effective wave vector associated with the Raman field pulses using modified field parameters, we can increase the sensitivity of the signal to the point where the quantum corrections can be measured. The expressions that are derived can be evaluated numerically to isolate the contribution to the signal from an external test mass. The regions of validity of the exact and approximate expressions are determined.

preprint2014arXiv

Optimization and error model for atom interferometry technique to measure Newtonian gravitational constant

Considered contribution to the phase of the atom interferometer caused by the gravity field of the massive proof mass. Demonstrated the method of finding the extrema of this contribution for 100kg Tungsten proof mass of the specific shape and specific parameters of $^{133}Cs$ atom interferometers. Calculated variations of the double difference response under the small deviations of atomic and proof mass variables. The choice of the extremal values of the atomic variables allows one to release requirements for atom positioning on 2 orders of magnitude.