Researcher profile

Andrew R. Schwartz

Andrew R. Schwartz contributes to research discovery and scholarly infrastructure.

ResearcherAffiliation not importedOpen to collaborate

Trust snapshot

Quick read

Trust 13 - Baseline
2works
0followers
2topics
3close collaborators

Actions

Decide how to stay connected

Follow researcher0

Research graph

See the researcher in context

Open full explorer

Inspect adjacent work, topics, institutions and collaborators without jumping out to a separate graph page.

Building this graph slice

BZPEER is loading the nearby papers, people, topics and institutions for this page.

Published work

2 published item(s)

preprint2011arXiv

Near-field scanning microwave microscope for interline capacitance characterization of nanoelectronics interconnect

We have developed a noncontact method for measurement of the interline capacitance in Cu/low-k interconnect. It is based on a miniature test vehicle with net capacitance of a few femto-Farads formed by two 20-μm-long parallel wires (lines) with widths and spacings the same as those of the interconnect wires of interest. Each line is connected to a small test pad. The vehicle impedance is measured at 4 GHz by a near-field microwave probe with 10 μm probe size via capacitive coupling of the probe to the vehicle's test pads. Full 3D finite element modeling at 4 GHz confirms that the microwave radiation is concentrated between the two wires forming the vehicle. An analytical lumped element model and a short/open calibration approach have been proposed to extract the interline capacitance value from the measured data. We have validated the technique on several test vehicles made with copper and low-k dielectric on a 300 mm wafer. The vehicles interline spacing ranges from 0.09 to 1 μm and a copper line width is 0.15 μm. This is the first time a near-field scanning microwave microscope has been applied to measure the lumped element impedance of a test vehicle.

preprint2011arXiv

Noncontact dielectric constant metrology of low-k interconnect films using a near-field scanned microwave probe

We present a method for noncontact, noninvasive measurements of dielectric constant, k, of 100-nm- to 1.5-μm-thick blanket low-k interconnect films on up to 300 mm in diameter wafers. The method has about 10 micron sampling spot size, and provides <0.3% precision and <2% accuracy for k-value. It is based on a microfabricated near-field scanned microwave probe formed by a 4 GHz parallel strip transmission line resonator tapered down to a few-micron tip size.