Researcher profile

Andrea Ianni

Andrea Ianni contributes to research discovery and scholarly infrastructure.

ResearcherAffiliation not importedOpen to collaborate

Trust snapshot

Quick read

Trust 21 - EmergingVerification L1Unclaimed author
7works
0followers
8topics
4close collaborators

Actions

Decide how to stay connected

Follow researcher0

Identity and collaboration

How to connect with this researcher

Claiming links this public author record to a researcher profile and unlocks direct collaboration workflows.

Log in to claim

Direct collaboration

Open a focused conversation when the fit is right

Claim this author entity first to unlock direct invitations.

Research graph

See the researcher in context

Open full explorer

Inspect adjacent work, topics, institutions and collaborators without jumping out to a separate graph page.

Building this graph slice

BZPEER is loading the nearby papers, people, topics and institutions for this page.

Published work

7 published item(s)

preprint2022arXiv

Search for Low-Energy Signals from Fast Radio Bursts with the Borexino Detector

The search for neutrino events in correlation with several of the most intense fast radio bursts (FRBs) has been performed using the Borexino data. We have searched for signals with visible energies above $250$~keV within a time window of $\pm$1000~s corresponding to the detection time of a particular FRB. We also applied an alternative approach based on searching for specific shapes of neutrino-electron scattering spectra in the full exposure spectrum of the Borexino detector. In particular, two incoming neutrino spectra were considered: the monoenergetic line and the spectrum expected from supernovae. The same spectra were considered for electron antineutrinos detected through the inverse beta-decay reaction. No statistically significant excess over the background was observed. As a result, the strongest upper limits on FRB-associated neutrino fluences of all flavors have been obtained in the $0.5 - 50$~MeV neutrino energy range.

preprint2021arXiv

Correlated and Integrated Directionality for sub-MeV solar neutrinos in Borexino

Liquid scintillator detectors play a central role in the detection of neutrinos from various sources. In particular, it is the only technique used so far for the precision spectroscopy of sub-MeV solar neutrinos, as demonstrated by the Borexino experiment at the Gran Sasso National Laboratory in Italy. The benefit of a high light yield, and thus a low energy threshold and a good energy resolution, comes at the cost of the directional information featured by water Cherenkov detectors, measuring $^8$B solar neutrinos above a few MeV. In this paper we provide the first directionality measurement of sub-MeV solar neutrinos which exploits the correlation between the first few detected photons in each event and the known position of the Sun for each event. This is also the first signature of directionality in neutrinos elastically scattering off electrons in a liquid scintillator target. This measurement exploits the sub-dominant, fast Cherenkov light emission that precedes the dominant yet slower scintillation light signal. Through this measurement, we have also been able to extract the rate of $^{7}$Be solar neutrinos in Borexino. The demonstration of directional sensitivity in a traditional liquid scintillator target paves the way for the possible exploitation of the Cherenkov light signal in future kton-scale experiments using liquid scintillator targets. Directionality is important for background suppression as well as the disentanglement of signals from various sources.

preprint2021arXiv

First Directional Measurement of sub-MeV Solar Neutrinos with Borexino

We report the measurement of sub-MeV solar neutrinos through the use of their associated Cherenkov radiation, performed with the Borexino detector at the Laboratori Nazionali del Gran Sasso. The measurement is achieved using a novel technique that correlates individual photon hits of events to the known position of the Sun. In an energy window between 0.54 MeV to 0.74 MeV, selected using the dominant scintillation light, we have measured 10887$^{+2386}_{-2103} (\mathrm{stat.})\pm 947 (\mathrm{syst.})$ ($68\%$ confidence interval) solar neutrinos out of 19904 total events. This corresponds to a $^{7}$Be neutrino interaction rate of 51.6$^{+13.9}_{-12.5}$ counts/(day$\cdot$ 100 ton), which is in agreement with the Standard Solar Model predictions and the previous spectroscopic results of Borexino. The no-neutrino hypothesis can be excluded with $>$5$σ$ confidence level. For the first time, we have demonstrated the possibility of utilizing the directional Cherenkov information for sub-MeV solar neutrinos, in a large-scale, high light yield liquid scintillator detector. This measurement provides an experimental proof of principle for future hybrid event reconstruction using both Cherenkov and scintillation signatures simultaneously.

preprint2020arXiv

Comprehensive geoneutrino analysis with Borexino

This paper presents a geoneutrino measurement using 3262.74 days of data taken with the Borexino detector at LNGS in Italy. By observing $52.6 ^{+9.4}_{-8.6} ({\rm stat}) ^{+2.7}_{-2.1}({\rm sys})$ geoneutrinos (68% interval) from $^{238}$U and $^{232}$Th, a signal of $47.0^{+8.4}_{-7.7}\,({\rm stat)}^{+2.4}_{-1.9}\,({\rm sys})$ TNU with $^{+18.3}_{-17.2}$% total precision was obtained. This result assumes the same Th/U mass ratio found in chondritic CI meteorites but compatible results were found when contributions from $^{238}$U and $^{232}$Th were fit as free parameters. Antineutrino background from reactors is fit unconstrained and found compatible with the expectations. The null-hypothesis of observing a signal from the mantle is excluded at a 99.0% C.L. when exploiting the knowledge of the local crust. Measured mantle signal of $21.2 ^{+9.6}_{-9.0} ({\rm stat})^{+1.1}_{-0.9} ({\rm sys})$ TNU corresponds to the production of a radiogenic heat of $24.6 ^{+11.1}_{-10.4}$ TW (68% interval) from $^{238}$U and $^{232}$Th in the mantle. Assuming 18% contribution of $^{40}$K in the mantle and $8.1^{+1.9}_{-1.4}$ TW of radiogenic heat of the lithosphere, the Borexino estimate of the total Earth radiogenic heat is $38.2 ^{+13.6}_{-12.7}$ TW, corresponding to a convective Urey ratio of 0.78$^{+0.41}_{-0.28}$. These values are compatible with different geological models, however there is a 2.4$σ$ tension with those which predict the lowest concentration of heat-producing elements. By fitting the data with a constraint on the reactor antineutrino background, the existence of a hypothetical georeactor at the center of the Earth having power greater than 2.4 TW at 95% C.L. is excluded. Particular attention is given to all analysis details, which should be of interest for the next generation geoneutrino measurements.

preprint2020arXiv

Constraints on Flavor-Diagonal Non-Standard Neutrino Interactions from Borexino Phase-II

The Borexino detector measures solar neutrino fluxes via neutrino-electron elastic scattering. Observed spectra are determined by the solar-$ν_{e}$ survival probability $P_{ee}(E)$, and the chiral couplings of the neutrino and electron. Some theories of physics beyond the Standard Model postulate the existence of Non-Standard Interactions (NSI's) which modify the chiral couplings and $P_{ee}(E)$. In this paper, we search for such NSI's, in particular, flavor-diagonal neutral current interactions that modify the $ν_e e$ and $ν_τe$ couplings using Borexino Phase II data. Standard Solar Model predictions of the solar neutrino fluxes for both high- and low-metallicity assumptions are considered. No indication of new physics is found at the level of sensitivity of the detector and constraints on the parameters of the NSI's are placed. In addition, with the same dataset the value of $\sin^2θ_W$ is obtained with a precision comparable to that achieved in reactor antineutrino experiments.

preprint2020arXiv

Improved measurement of $^8$B solar neutrinos with 1.5 kt y of Borexino exposure

We report on an improved measurement of the $^8$B solar neutrino interaction rate with the Borexino experiment at the Laboratori Nazionali del Gran Sasso. Neutrinos are detected via their elastic scattering on electrons in a large volume of liquid scintillator. The measured rate of scattered electrons above 3 MeV of energy is $0.223\substack{+0.015 \\ -0.016}\,(stat)\,\substack{+0.006 \\ -0.006}\,(syst)$ cpd/100 t, which corresponds to an observed solar neutrino flux assuming no neutrino flavor conversion of $Φ\substack{\rm ES \\ ^8\rm B}=2.57\substack{+0.17 \\ -0.18}(stat)\substack{+0.07\\ -0.07}(syst)\times$10$^6$ cm$^{-2}\,$s$^{-1}$. This measurement exploits the active volume of the detector in almost its entirety for the first time, and takes advantage of a reduced radioactive background following the 2011 scintillator purification campaign and of novel analysis tools providing a more precise modeling of the background. Additionally, we set a new limit on the interaction rate of solar $hep$ neutrinos, searched via their elastic scattering on electrons as well as their neutral current-mediated inelastic scattering on carbon, $^{12}$C($ν,ν'$)$^{12}$C* ($E_γ$= 15.1 MeV).

preprint2018arXiv

Speeding up complex multivariate data analysis in Borexino with parallel computing based on Graphics Processing Unit

A spectral fitter based on the graphics processor unit (GPU) has been developed for Borexino solar neutrino analysis. It is able to shorten the fitting time to a superior level compared to the CPU fitting procedure. In Borexino solar neutrino spectral analysis, fitting usually requires around one hour to converge since it includes time-consuming convolutions in order to account for the detector response and pile-up effects. Moreover, the convergence time increases to more than two days when including extra computations for the discrimination of $^{11}$C and external $γ$s. In sharp contrast, with the GPU-based fitter it takes less than 10 seconds and less than four minutes, respectively. This fitter is developed utilizing the GooFit project with customized likelihoods, pdfs and infrastructures supporting certain analysis methods. In this proceeding the design of the package, developed features and the comparison with the original CPU fitter are presented.