Source author record

Amit Ashok

Amit Ashok appears in the imported research catalog. Authorship, coauthor and topic links are available while profile ownership is still unclaimed.

ResearcherUnclaimed source record

Catalog footprint

What is connected

5works
7topics
4close collaborators

Actions

Connect this record

Log in to claim

Research graph

See the researcher in context

Open full explorer

Inspect adjacent papers, topics, institutions and collaborators without losing the researcher page.

Building this map preview

BZPEER is loading the nearby papers, people, topics and institutions for this page.

Published work

5 published item(s)

preprint2022arXiv

Quantum Multi-Parameter Adaptive Bayesian Estimation and Application to Super-Resolution Imaging

In Bayesian estimation theory, the estimator ${\hat θ} = E[θ|l]$ attains the minimum mean squared error (MMSE) for estimating a scalar parameter of interest $θ$ from the observation of $l$ through a noisy channel $P_{l|θ}$, given a prior $P_θ$ on $θ$. In quantum sensing tasks, the user gets $ρ_θ$, the quantum state that encodes $θ$. They choose a measurement, a positive-operator valued measure (POVM) $Π_l$, which induces the channel $P_{l|θ} = {\rm Tr}(ρ_θΠ_l)$ to the measurement outcome $l$, on which the aforesaid classical MMSE estimator is employed. Personick found the optimum POVM $Π_l$ that minimizes the MMSE over all possible measurements, and that MMSE. This result from 1971 is less-widely known than the quantum Fisher information (QFI), which lower bounds the variance of an unbiased estimator over all measurements, when $P_θ$ is unavailable. For multi-parameter estimation, i.e., when $θ$ is a vector, in Fisher quantum estimation theory, the inverse of the QFI matrix provides an operator lower bound to the covariance of an unbiased estimator. However, there has been little work on quantifying quantum limits and measurement designs, for multi-parameter quantum estimation in the {\em Bayesian} setting. In this paper, we build upon Personick's result to construct a Bayesian adaptive measurement scheme for multi-parameter estimation when $N$ copies of $ρ_θ$ are available. We illustrate an application to localizing a cluster of point emitters in a highly sub-Rayleigh angular field-of-view, an important problem in fluorescence microscopy and astronomy. Our algorithm translates to a multi-spatial-mode transformation prior to a photon-detection array, with electro-optic feedback to adapt the mode sorter. We show that this receiver performs far superior to quantum-noise-limited focal-plane direct imaging.

preprint2021arXiv

Bounds on mutual information of mixture data for classification tasks

The data for many classification problems, such as pattern and speech recognition, follow mixture distributions. To quantify the optimum performance for classification tasks, the Shannon mutual information is a natural information-theoretic metric, as it is directly related to the probability of error. The mutual information between mixture data and the class label does not have an analytical expression, nor any efficient computational algorithms. We introduce a variational upper bound, a lower bound, and three estimators, all employing pair-wise divergences between mixture components. We compare the new bounds and estimators with Monte Carlo stochastic sampling and bounds derived from entropy bounds. To conclude, we evaluate the performance of the bounds and estimators through numerical simulations.

preprint2020arXiv

X-ray measurement model incorporating energy-correlated material variability and its application in information-theoretic system analysis

Extending our prior work, we propose a multi-energy X-ray measurement model incorporating material variability with energy correlations to enable the analysis and exploration of the performance of X-ray imaging and sensing systems. Based on this measurement model, we provide analytical expressions for bounds on the probability of error, $P_e$, to quantify the performance limits of an X-ray measurement system for binary classification task. We analyze the performance of a prototypical X-ray measurement system to demonstrate the utility of our proposed material variability measurement model.

preprint2019arXiv

Approaching Quantum Limited Super-Resolution Imaging without Prior Knowledge of the Object Location

A recently identified class of receivers which demultiplex an optical field into a set of orthogonal spatial modes prior to detection can surpass canonical diffraction limits on spatial resolution for simple incoherent imaging tasks. However, these mode-sorting receivers tend to exhibit high sensitivity to contextual nuisance parameters (e.g., the centroid of a clustered or extended object), raising questions on their viability in realistic imaging scenarios where little or no prior information about the scene is available. We propose a multi-stage passive imaging strategy which segments the total recording time between different physical measurements to build up the required prior information for near quantum-optimal imaging performance at sub-Rayleigh length scales. We show via Monte Carlo simulations that an adaptive two-stage scheme which dynamically allocates the total recording time between a traditional direct detection measurement and a binary mode-sorting receiver outperforms idealized direct detection alone for simple estimation tasks when no prior knowledge of the object centroid is available, achieving one to two orders of magnitude improvement in mean squared error. Our scheme can be generalized for more sophisticated imaging tasks with multiple parameters and minimal prior information.

preprint2016arXiv

ReconNet: Non-Iterative Reconstruction of Images from Compressively Sensed Random Measurements

The goal of this paper is to present a non-iterative and more importantly an extremely fast algorithm to reconstruct images from compressively sensed (CS) random measurements. To this end, we propose a novel convolutional neural network (CNN) architecture which takes in CS measurements of an image as input and outputs an intermediate reconstruction. We call this network, ReconNet. The intermediate reconstruction is fed into an off-the-shelf denoiser to obtain the final reconstructed image. On a standard dataset of images we show significant improvements in reconstruction results (both in terms of PSNR and time complexity) over state-of-the-art iterative CS reconstruction algorithms at various measurement rates. Further, through qualitative experiments on real data collected using our block single pixel camera (SPC), we show that our network is highly robust to sensor noise and can recover visually better quality images than competitive algorithms at extremely low sensing rates of 0.1 and 0.04. To demonstrate that our algorithm can recover semantically informative images even at a low measurement rate of 0.01, we present a very robust proof of concept real-time visual tracking application.