Researcher profile

Allard P. Mosk

Allard P. Mosk contributes to research discovery and scholarly infrastructure.

ResearcherAffiliation not importedOpen to collaborate

Trust snapshot

Quick read

Trust 21 - EmergingVerification L1Unclaimed author
9works
0followers
6topics
4close collaborators

Actions

Decide how to stay connected

Follow researcher0

Identity and collaboration

How to connect with this researcher

Claiming links this public author record to a researcher profile and unlocks direct collaboration workflows.

Log in to claim

Direct collaboration

Open a focused conversation when the fit is right

Claim this author entity first to unlock direct invitations.

Research graph

See the researcher in context

Open full explorer

Inspect adjacent work, topics, institutions and collaborators without jumping out to a separate graph page.

Building this graph slice

BZPEER is loading the nearby papers, people, topics and institutions for this page.

Published work

9 published item(s)

preprint2023arXiv

Sensor fusion in ptychography

Ptychography is a lensless, computational imaging method that utilises diffraction patterns to determine the amplitude and phase of an object. In transmission ptychography, the diffraction patterns are recorded by a detector positioned along the optical axis downstream of the object. The light scattered at the highest diffraction angle carries information about the finest structures of the object. We present a setup to simultaneously capture a signal near the optical axis and a signal scattered at high diffraction angles. Moreover, we present an algorithm based on a shifted angular spectrum method and automatic differentiation that utilises this recorded signal. By jointly reconstructing the object from the resulting low and high diffraction angle images, the resolution of the reconstructed image is improved remarkably. The effective numerical aperture of the compound sensor is determined by the maximum diffraction angle captured by the off axis sensor.

preprint2022arXiv

Mode mapping Q > 500 000 photonic crystal nanocavities using free carrier absorption

We demonstrate a nonlinear photomodulation spectroscopy method to image the mode profile of a high-Q photonic crystal resonator (PhCR). This far-field imaging method is suitable for ultrahigh-Q cavities which we demonstrate on a Q = 619000 PhCR. We scan the PhCR surface with a 405 nm pump beam that modulates the refractive index by local thermal tuning, while probing the response of the resonance. We enhance resolution by probing at high power, using the thermo-optical nonlinearity of the PhCR. Spatial resolution of the thermo-optical effect is typically constrained by the broad thermal profile of the optical pump. Here we go beyond the thermal limit and show that we can approach the diffraction limit of the pump light. This is due to free carrier absorption that heats up the PhCR only when there is overlap between the optical pump spot and the optical mode profile. This is supported with a thermo-optical model that reproduces the high-resolution mode mapping. Results reveal that the observed enhanced resolution is reached for surprisingly low carrier density.

preprint2022arXiv

Sub-nanometer measurement of transient structural changes in dye-doped polystyrene microspheres

We present an interferometric spectral-domain optical coherence tomography microscopy setup to detect structural changes using interference of light reflected from different interfaces of the sample. We induce a reproducible nanometer-scale size change in dye-doped 10$~μ$m polystyrene microspheres by the release of Stokes shift energy of dye molecules inside the microspheres, excited by a modulated 532-nm laser. The resulting optical path length difference was measured with a sensitivity of 0.4$~pm/\sqrt{Hz}$ limited by photodetection noise, and reveals elastic as well as inelastic responses, which opens up possibilities for measuring the response of cell-sized biological objects.

preprint2021arXiv

Efficient and flexible approach to ptychography using an optimization framework based on automatic differentiation

Ptychography is a lensless imaging method that allows for wavefront sensing and phase-sensitive microscopy from a set of diffraction patterns. Recently, it has been shown that the optimization task in ptychography can be achieved via automatic differentiation (AD). Here, we propose an open-access AD-based framework implemented with TensorFlow, a popular machine learning library. Using simulations, we show that our AD-based framework performs comparably to a state-of-the-art implementation of the momentum-accelerated ptychographic iterative engine (mPIE) in terms of reconstruction speed and quality. AD-based approaches provide great flexibility, as we demonstrate by setting the reconstruction distance as a trainable parameter. Lastly, we experimentally demonstrate that our framework faithfully reconstructs a biological specimen.

preprint2021arXiv

Optimizing illumination for precise multi-parameter estimations in coherent diffractive imaging

Coherent diffractive imaging (CDI) is widely used to characterize structured samples from measurements of diffracting intensity patterns. We introduce a numerical framework to quantify the precision that can be achieved when estimating any given set of parameters characterizing the sample from measured data. The approach, based on the calculation of the Fisher information matrix, provides a clear benchmark to assess the performance of CDI methods. Moreover, by optimizing the Fisher information metric using deep learning optimization libraries, we demonstrate how to identify the optimal illumination scheme that minimizes the estimation error under specified experimental constrains. This work paves the way for an efficient characterization of structured samples at the sub-wavelength scale.

preprint2021arXiv

Roadmap on Wavefront Shaping and deep imaging in complex media

The last decade has seen the development of a wide set of tools, such as wavefront shaping, computational or fundamental methods, that allow to understand and control light propagation in a complex medium, such as biological tissues or multimode fibers. A vibrant and diverse community is now working on this field, that has revolutionized the prospect of diffraction-limited imaging at depth in tissues. This roadmap highlights several key aspects of this fast developing field, and some of the challenges and opportunities ahead.

preprint2020arXiv

Imaging through highly scattering environments using ballistic and quasi-ballistic light in a common-path Sagnac interferometer

The survival of time-reversal symmetry in the presence of strong multiple scattering lies at the heart of some of the most robust interference effects of light in complex media. Here, the use of time-reversed light paths for imaging in highly scattering environments is investigated. A common-path Sagnac interferometer is constructed which is able to detect objects behind a layer of strongly scattering material through up to 14 mean free paths total attenuation length. A spatial offset between the two light paths is used to suppress non-specific scattering contributions, limiting the signal to the volume of overlap. Scaling of the specific signal intensity indicates a transition from ballistic to quasi-ballistic contributions as the scattering thickness is increased. The characteristic frequency dependence for the coherent modulation signal provides a path length dependent signature, while the spatial overlap requirement allows for short-range 3D imaging. The technique of common-path, bistatic interferometry offers a conceptually novel approach which could open new applications in diverse areas such as medical imaging, machine vision, sensors, and lidar.

preprint2020arXiv

Optical transmission matrix measurement sampled on a dense hexagonal lattice

The optical transmission matrix (TM) characterizes the transmission properties of a sample. We show a novel experimental procedure for measuring the TM of light waves in a slab geometry based on sampling the light field on a hexagonal lattice at the Rayleigh criterion. Our method enables the efficient measurement of a large fraction of the complete TM without oversampling while minimizing sampling crosstalk and the associated distortion of the statistics of the matrix elements. The procedure and analysis described here is demonstrated on a clear sample which serves as an important reference for other systems and geometries such as dense scattering media.

preprint2020arXiv

Thermo-optical dynamics of a nonlinear GaInP photonic crystal nanocavity depend on the optical mode profile

We measure the dynamics of the thermo-optical nonlinearity of both a mode-gap nanocavity and a delocalized mode in a Ga$_{\mathrm{0.51}}$In$_{\mathrm{0.49}}$P photonic crystal membrane. We model these results in terms of heat transport and thermo-optical response in the material. By step-modulating the optical input power we push the nonlinear resonance to jump between stable branches of its response curve, causing bistable switching. An overshoot of the intensity followed by a relaxation tail is observed upon bistable switching. In this way, the thermal relaxation of both the localized resonance and the delocalized resonance is measured. Significant difference in decay time is observed and related to the optical mode profile of the resonance. We reproduce the observed transient behavior with our thermo-optical model, implementing a non-instantaneous nonlinearity, and taking into account the optical mode profile of the resonance, as experimentally measured.