Source author record

Alexey I. Gubin

Alexey I. Gubin appears in the imported research catalog. Authorship, coauthor and topic links are available while profile ownership is still unclaimed.

ResearcherUnclaimed source record

Catalog footprint

What is connected

3works
4topics
4close collaborators

Actions

Connect this record

Log in to claim

Research graph

See the researcher in context

Open full explorer

Inspect adjacent papers, topics, institutions and collaborators without losing the researcher page.

Building this map preview

BZPEER is loading the nearby papers, people, topics and institutions for this page.

Published work

3 published item(s)

preprint2022arXiv

Quartz Whispering-Gallery-Mode Resonator with Microfluidic Chip as Sensor for Permittivity Measurement of Liquids

Studies of biological solutions require high measurement accuracy, the ability to detect low changes in substance concentration, and small amounts of the liquid under test. A microwave complex permittivity measurement technique based on a high-quality-factor whispering-gallery-mode resonator with a microfluidic chip allows small amounts of dielectric liquids to be investigated with high accuracy. An existing technique based on a sapphire resonator does not provide for a low-concentration detection limit for substances with low molecular weight. Here, we present an advanced technique based on a quartz dielectric resonator. The detection limit obtained for glucose in water solution was found to be about one order of magnitude lower for the quartz resonator cell than for the sapphire-resonator-based measurement cell. The limit is about or lower than the concentration of glucose in human blood. This fact means that the technique can be used as the sensor for investigations of biological solutions in the microwave range. A study of glucose, lactalbumin, and bovine serum albumin was successfully performed in the Ka -band using the developed sensor.

preprint2022arXiv

Single Whispering-Gallery-Mode Resonator With Microfluidic Chip as a Basis for Multifrequency Microwave Permittivity Measurement of Liquids

The accurate measurement of complex liquid permittivity in a frequency range provides important information on liquid properties in comparison to single frequency permittivity investigations. The multifrequency microwave characterization technique based on a single quartz whispering-gallery-mode (WGM) resonator with a microfluidic chip are proposed, developed, and demonstrated. This technique allows the complex permittivity of small volumes of liquid to be measured at six resonant frequencies in the 30-40 GHz frequency range. The calibration is performed by simulating the measurement cell and by plotting the calibration nomogram charts for all six investigated frequencies. The novel approach is applied in studies of the complex permittivity of the L-lysine in water solutions. The results open up possibilities to investigate the complex permittivity of biological liquids at several frequencies and to further develop the microwave dielectrometry of small liquid volumes in a certain frequency range using the quasi-optical nature of a single high-Q WGM resonator.

preprint2019arXiv

Microwave Quenching in DC-biased Coplanar Waveguide Based on $YBa_2Cu_3O_{7-δ}$ Thin Film

In this paper, we report on the results of features in the discovered effect of a strong change in the microwave losses (quenching) in HTS-based coplanar waveguide (CPW) at certain values of the input power $P_{in}$ and direct current (DC) $I_{dc}$. Two waveguides were studied: CPW-150 and CPW-75, fabricated of epitaxial 150 nm and 75 nm YBCO films. The insertion loss of CPW, $IL = 10 lg (P_{out} / P_{in})$, was measured versus both the operating temperature and the bias DC current $I_{dc}$ when a fixed level of the input X-band pulsed MW signal $P_{in}$ was applied. Here $P_{out}$ is the power measured at the CPW output. A pulse duration $τ_i$ was 5 $μs$ with pulse repetition period T = 40 $μs$. Experiments showed a noticeable difference in specific values of $I^*= I_{dc}$ corresponding to the $P_{in}$ dependent quenching phenomenon in CPW-150 and CPW-75. With a weak input signal the difference in behavior of CPWs is anticipated, i.e., quenching occurs at a lower current for thinner film. For $P_{in}>1W$ the situation is opposite, i.e., quenching for CPW-150 takes place at a lower $I^*$. This is explained by stronger microwave heating of CPW-150.