Source author record

Alexander Urech

Alexander Urech appears in the imported research catalog. Authorship, coauthor and topic links are available while profile ownership is still unclaimed.

ResearcherUnclaimed source record

Catalog footprint

What is connected

3works
5topics
4close collaborators

Actions

Connect this record

Log in to claim

Research graph

See the researcher in context

Open full explorer

Inspect adjacent papers, topics, institutions and collaborators without losing the researcher page.

Building this map preview

BZPEER is loading the nearby papers, people, topics and institutions for this page.

Published work

3 published item(s)

preprint2022arXiv

Narrow-line imaging of single strontium atoms in shallow optical tweezers

Single strontium atoms held in optical tweezers have so far only been imaged using the broad $^{1\hspace{-0.3ex}}S_0$-$^{1\hspace{-0.3ex}}P_1$ transition. For Yb, use of the narrow (183 kHz-wide) $^{1\hspace{-0.3ex}}S_0$-$^{3\hspace{-0.3ex}}P_1$ transition for simultaneous imaging and cooling has been demonstrated in tweezers with a magic wavelength for the imaging transition. We demonstrate high-fidelity imaging of single Sr atoms using its even narrower (7.4 kHz-wide) $^{1\hspace{-0.3ex}}S_0$ - $^{3\hspace{-0.3ex}}P_1$ transition. The atoms are trapped in \textit{non}-magic-wavelength tweezers. We detect the photons scattered during Sisyphus cooling, thus keeping the atoms near the motional ground state of the tweezer throughout imaging. The fidelity of detection is 0.9991(4) with a survival probability of 0.97(2). An atom in a tweezer can be held under imaging conditions for 79(3) seconds allowing for hundreds of images to be taken, limited mainly by background gas collisions. We detect atoms in an arrary of 36 tweezers with 813.4-nm light and trap depths of 135(20) $μ$K. This trap depth is three times shallower than typically used for imaging on the broad $^{1\hspace{-0.3ex}}S_0$ - $^{1\hspace{-0.3ex}}P_1$ transition. Narrow-line imaging opens the possibility to even further reduce this trap depth, as long as all trap frequencies are kept larger than the imaging transition linewidth. Imaging using a narrow-linewidth transition in a non-magic-wavelength tweezer also allows for selective imaging of a given tweezer. As a demonstration, we selectively image (hide) a single tweezer from the array. This provides a useful tool for quantum error correction protocols.

preprint2022arXiv

Solving correlation clustering with QAOA and a Rydberg qudit system: a full-stack approach

We study the correlation clustering problem using the quantum approximate optimization algorithm (QAOA) and qudits, which constitute a natural platform for such non-binary problems. Specifically, we consider a neutral atom quantum computer and propose a full stack approach for correlation clustering, including Hamiltonian formulation of the algorithm, analysis of its performance, identification of a suitable level structure for ${}^{87}{\rm Sr}$ and specific gate design. We show the qudit implementation is superior to the qubit encoding as quantified by the gate count. For single layer QAOA, we also prove (conjecture) a lower bound of $0.6367$ ($0.6699$) for the approximation ratio on 3-regular graphs. Our numerical studies evaluate the algorithm's performance by considering complete and Erdős-Rényi graphs of up to 7 vertices and clusters. We find that in all cases the QAOA surpasses the Swamy bound $0.7666$ for the approximation ratio for QAOA depths $p \geq 2$. Finally, by analysing the effect of errors when solving complete graphs we find that their inclusion severely limits the algorithm's performance.

preprint2020arXiv

Microscope objective for imaging atomic strontium with 0.63 micrometer resolution

Imaging and manipulating individual atoms with submicrometer separation can be instrumental for quantum simulation of condensed matter Hamiltonians and quantum computation with neutral atoms. Quantum gas microscope experiments in most cases rely on quite costly solutions. Here we present an open-source design of a microscope objective for atomic strontium consisting solely of off-the-shelf lenses that is diffraction-limited for 461${\,}$nm light. A prototype built with a simple stacking design is measured to have a resolution of 0.63(4)${\,μ}$m, which is in agreement with the predicted value. This performance, together with the near diffraction-limited performance for 532${\,}$nm light makes this design useful for both quantum gas microscopes and optical tweezer experiments with strontium. Our microscope can easily be adapted to experiments with other atomic species such as erbium, ytterbium, and dysprosium, as well as Rydberg experiments with rubidium.