Source author record

Alexander Eichler

Alexander Eichler appears in the imported research catalog. Authorship, coauthor and topic links are available while profile ownership is still unclaimed.

ResearcherUnclaimed source record

Catalog footprint

What is connected

10works
6topics
4close collaborators

Actions

Connect this record

Log in to claim

Research graph

See the researcher in context

Open full explorer

Inspect adjacent papers, topics, institutions and collaborators without losing the researcher page.

Building this map preview

BZPEER is loading the nearby papers, people, topics and institutions for this page.

Published work

10 published item(s)

preprint2022arXiv

Force-detected Magnetic Resonance Imaging of Influenza Viruses in the Overcoupled Sensor Regime

Long and thin scanning force cantilevers are sensitive to small forces, but also vulnerable to detrimental non-contact interactions. Here we present an experiment with a cantilever whose spring constant and static deflection are dominated by the interaction between the tip and the surface, a regime that we refer to as ``overcoupled''. The interactions are an obstacle for ultrasensitive measurements like nanoscale magnetic resonance imaging (nanoMRI). We discuss several strategies to overcome the challenges presented by the overcoupling, and demonstrate proton nanoMRI measurements of individual influenza virus particles.

preprint2022arXiv

Ising machines with strong bilinear coupling

Networks of coupled parametric resonators (parametrons) hold promise for parallel computing architectures. En route to realizing complex networks, we report an experimental and theoretical analysis of two coupled parametrons. In contrast to previous studies, we explore the case of strong bilinear coupling between the parametrons, as well as the role of detuning. We show that the system can still operate as an Ising machine in this regime, even though careful calibration is necessary to ensure that the correct solution space is available. Apart from the formation of split normal modes, new states of mixed symmetry are generated. Furthermore, we predict that systems with $N>2$ parametrons will undergo multiple phase transitions before arriving at a regime that can be equivalent to the Ising problem.

preprint2022arXiv

Soft-clamped silicon nitride string resonators at millikelvin temperatures

We demonstrate that soft-clamped silicon nitride strings with large aspect ratio can be operated at \si{\milli\kelvin} temperatures. The quality factors ($Q$) of two measured devices show consistent dependency on the cryostat temperature, with soft-clamped mechanical modes reaching $Q > 10^9$ at $46~\mathrm{mK}$. For low optical readout power, $Q$ is found to saturate, indicating good thermalization between the sample and the stage it is mounted on. Our best device exhibits a force sensitivity of $9.6~\mathrm{zN}/\sqrt{\mathrm{Hz}}$ and a thermal decoherence time of $0.38~\mathrm{s}$ which bode well for future applications such as nanomechanical force sensing and beyond.

preprint2022arXiv

Ultra-High Q Nanomechanical Resonators for Force Sensing

Nanomechanical resonators with ultra-high quality factors have become a central element in fundamental research, enabling measurements below the standard quantum limit and the preparation of long-lived quantum states. Here, I propose that such resonators will allow the detection of electron and nuclear spins with high spatial resolution, paving the way to future nanoscale magnetic resonance imaging instruments. The article lists the challenges that must be overcome before this vision can become reality, and indicates potential solutions.

preprint2021arXiv

Spatially resolved surface dissipation over metal and dielectric substrates

We report spatially resolved measurements of static and fluctuating electric fields over conductive (Au) and non-conductive (SiO2) surfaces. Using an ultrasensitive `nanoladder' cantilever probe to scan over these surfaces at distances of a few tens of nanometers, we record changes in the probe resonance frequency and damping that we associate with static and fluctuating fields, respectively. We find that the two quantities are spatially correlated and of similar magnitude for the two materials. We quantitatively describe the observed effects on the basis of trapped surface charges and dielectric fluctuations in an adsorbate layer. Our results provide direct, spatial evidence for surface dissipation in adsorbates that affects nanomechanical sensors, trapped ions, superconducting resonators, and color centers in diamond.

preprint2020arXiv

Membrane-based scanning force microscopy

We report the development of a scanning force microscope based on an ultra-sensitive silicon nitride membrane transducer. Our development is made possible by inverting the standard microscope geometry - in our instrument, the substrate is vibrating and the scanning tip is at rest. We present first topography images of samples placed on the membrane surface. Our measurements demonstrate that the membrane retains an excellent force sensitivity when loaded with samples and in the presence of a scanning tip. We discuss the prospects and limitations of our instrument as a quantum-limited force sensor and imaging tool.

preprint2016arXiv

Ultrasensitive hysteretic force sensing with parametric nonlinear oscillators

We propose a novel method for linear detection of weak forces using parametrically driven nonlinear resonators. The method is based on a peculiar feature in the response of the resonator to a near resonant periodic external force. This feature stems from a complex interplay between the parametric drive, external force and nonlinearities. For weak parametric drive, the response exhibits the standard Duffing-like single jump hysteresis. For stronger drive amplitudes, we find a qualitatively new double jump hysteresis which arises from stable solutions generated by the cubic Duffing nonlinearity. The additional jump exists only if the external force is present and the frequency at which it occurs depends linearly on the amplitude of the external force, permitting a straightforward ultrasensitive detection of weak forces. With state-of-the-art nanomechanical resonators, our scheme should permit force detection in the atto-newton range.

preprint2015arXiv

Nanotube mechanical resonators with quality factors of up to 5 million

Carbon nanotube mechanical resonators have attracted considerable interest because of their small mass, the high quality of their surface, and the pristine electronic states they host. However, their small dimensions result in fragile vibrational states that are difficult to measure. Here we observe quality factors $Q$ as high as $5\times10^6$ in ultra-clean nanotube resonators at a cryostat temperature of 30 mK, where we define $Q$ as the ratio of the resonant frequency over the linewidth. Measuring such high quality factors requires both employing an ultra-low noise method to detect minuscule vibrations rapidly, and carefully reducing the noise of the electrostatic environment. We observe that the measured quality factors fluctuate because of fluctuations of the resonant frequency. The quality factors we measure are record high; they are comparable to the highest $Q$ reported in mechanical resonators of much larger size, a remarkable result considering that reducing the size of resonators is usually concomitant with decreasing quality factors. The combination of ultra-low size and very large $Q$ offers new opportunities for ultra-sensitive detection schemes and quantum optomechanical experiments.

preprint2014arXiv

Atomic monolayer deposition on the surface of nanotube mechanical resonators

We studied monolayers of noble gas atoms (Xe, Kr, Ar, and Ne) deposited on individual ultra- clean suspended nanotubes. For this, we recorded the resonance frequency of the mechanical motion of the nanotube, since it provides a direct measure of the coverage. The latter is the number of adsorbed atoms divided by the number of the carbon atoms of the suspended nanotube. Monolayers formed when the temperature was lowered in a constant pressure of noble gas atoms. The coverage of Xe monolayers remained constant at 1/6 over a large temperature range. This finding reveals that Xe monolayers are solid phases with a triangular atomic arrangement, and are commensurate with the underlying carbon nanotube. By comparing our measurements to theoretical calculations, we identify the phases of Ar and Ne monolayers as fluids, and we tentatively describe Kr monolayers as solid phases. These results underscore that mechanical resonators made from single nanotubes are excellent probes for surface science.

preprint2012arXiv

Parametric amplification and self-oscillation in a nanotube mechanical resonator

A hallmark of mechanical resonators made from a single nanotube is that the resonance frequency can be widely tuned. Here, we take advantage of this property to realize parametric amplification and self-oscillation. The gain of the parametric amplification can be as high as 18.2 dB and tends to saturate at high parametric pumping due to nonlinear damping. These measurements allow us to determine the coefficient of the linear damping force. The corresponding damping rate is lower than the one obtained from the lineshape of the resonance (without pumping), supporting the recently reported scenario that describes damping in nanotube resonators by a nonlinear force. The possibility to combine nanotube resonant mechanics and parametric amplification holds promise for future ultra-low force sensing experiments.