Source author record

Alexander Deisting

Explore this author’s publications, collaborators and research topics. This catalog record has not been claimed by its author.

ResearcherUnclaimed source record

Catalog footprint

Research overview

2works
3topics
4close collaborators

Published work

2 publications

preprint2022arXiv

Contextual Isotope Ranking Criteria for Peak Identification in Gamma Spectroscopy Using a Large Database

Isotope identification is a recurrent problem in gamma spectroscopy with high purity germanium detectors. In this work, new strategies are introduced to facilitate this type of analysis. Five criteria are used to identify the parent isotopes making a query on a large database of gamma-lines from a multitude of isotopes producing an output list whose entries are sorted so that the gamma-lines with the highest chance of being present in a sample are placed at the top. A metric to evaluate the performance of the different criteria is introduced and used to compare them. Two of the criteria are found to be superior than the others: one based on fuzzy logic, and another that makes use of the gamma relative emission probabilities. A program called histoGe implements these criteria using a SQLite database containing the gamma-lines of isotopes which was parsed from WWW Table of Radioactive Isotopes. histoGe is Free Software and is provided along with the database so they can be used to analyze spectra obtained with generic gamma-ray detectors.

preprint2019arXiv

Towards a low cost lead assay technique for drinking water using CMOS sensors

An estimated 26 million people in low- and middle-income countries are at risk of lead exposure and there is no safe threshold for lead ingestion. Radio assay methods are not easily accessible in regions at risk, therefore a low cost and easy to use sensor is desirable. Pb\textrm{Pb} occurs together with traces of radioisotopes with decay energies in the range of 1010 to several \SI{100}{\kilo\electronvolt} and beyond. Such energies are accessible in silicon sensors. We have tested a scientific CMOS (Neo 5.5 sCMOS), optimised for optical wavelengths, as γγ detector for radiation in the range of 00 to a few 10 keV. We find a minimal detectable 241Am^{241}\textrm{Am} decay rate of 20 Bq for a < 1.4h measurement. Optimising our analysis software will potentially enable detecting lower rates in the same measurement time. We established that the Neo 5.5 sCMOS allows to measure a spectrum of 241Am^{241}\textrm{Am} decay lines. In addition we show that it is possible to enhance the concentration of radioisotopes in water when reducing the water's volume by boiling. The knowledge gained using the scientific CMOS sensor will be transferred to commercial silicon sensors as the chips in smart phones.

Research graph

See the researcher in context

Open full explorer

Inspect adjacent papers, topics, institutions and collaborators without losing the researcher page.

Building this map preview

BZPEER is loading the nearby papers, people, topics and institutions for this page.