Source author record

Alexander D. Cronin

Explore this author’s publications, collaborators and research topics. This catalog record has not been claimed by its author.

ResearcherUnclaimed source record

Catalog footprint

Research overview

8works
2topics
4close collaborators

Published work

8 publications

preprint2016arXiv

Analysis of polarizability measurements made with atom interferometry

We present revised measurements of the static electric dipole polarizabilities of K, Rb, and Cs based on atom interferometer experiments presented in [Phys. Rev. A 2015, 92, 052513] but now re-analyzed with new calibrations for the magnitude and geometry of the applied electric field gradient. The resulting polarizability values did not change, but the uncertainties were significantly reduced. Then we interpret several measurements of alkali metal atomic polarizabilities in terms of atomic oscillator strengths fikf_{ik}, Einstein coefficients AikA_{ik}, state lifetimes τkτ_{k}, transition dipole matrix elements DikD_{ik}, line strengths SikS_{ik}, and van der Waals C6C_6 coefficients. Finally, we combine atom interferometer measurements of polarizabilities with independent measurements of lifetimes and C6C_6 values in order to quantify the residual contribution to polarizability due to all atomic transitions other than the principal nsns-npJnp_J transitions for alkali metal atoms.

preprint2015arXiv

Atom Interferometer Gyroscope with Spin-Dependent Phase Shifts Induced by Light near a Tune-Out Wavelength

Tune-out wavelengths measured with an atom interferometer are sensitive to laboratory rotation rates because of the Sagnac effect, vector polarizability, and dispersion compensation. We observed shifts in measured tune-out wavelengths as large as 213 pm with a potassium atom beam interferometer, and we explore how these shifts can be used for an atom interferometer gyroscope.

preprint2015arXiv

Measurements of the Ground-State Polarizabilities of Cs, Rb, and K using Atom Interferometry

We measured the ground-state static electric-dipole polarizabilities of Cs, Rb, and K atoms using a three-nanograting Mach-Zehnder atom beam interferometer. Our measurements provide benchmark tests for atomic structure calculations and thus test the underlying theory used to interpret atomic parity non-conservation experiments. We measured αCs=4πε0×59.45(11)A˚3α_{\mathrm{Cs}} = 4πε_0 \times 59.45(11) Å^3, αRb=4πε0×47.44(9)A˚3α_{\mathrm{Rb}} = 4πε_0 \times 47.44(9) Å^3, and αK=4πε0×42.97(8)A˚3α_{\mathrm{K}} = 4πε_0 \times 42.97(8) Å^3. In atomic units, these measurements are αCs=401.2(7)α_{\mathrm{Cs}} = 401.2(7), αRb=320.1(6)α_{\mathrm{Rb}} = 320.1(6), and αK=290.0(5)α_{\mathrm{K}} = 290.0(5). We report ratios of polarizabilities αCs/αRb=1.2532(10)α_{\mathrm{Cs}}/α_{\mathrm{Rb}} = 1.2532(10), αCs/αK=1.3835(9)α_{\mathrm{Cs}}/α_{\mathrm{K}} = 1.3835(9), and αRb/αK=1.1040(9)α_{\mathrm{Rb}}/α_{\mathrm{K}} = 1.1040(9) with smaller fractional uncertainty because the systematic errors for individual measurements are largely correlated. Since Cs atom beams have short de Broglie wavelengths, we developed measurement methods that do not require resolved atom diffraction. Specifically, we used phase choppers to measure atomic beam velocity distributions, and we used electric field gradients to give the atom interference pattern a phase shift that depends on atomic polarizability.

preprint2013arXiv

Atom optical shop testing of electrostatic lenses using an atom interferometer

We used an atom interferometer for atom optical shop testing of lenses for atomic de Broglie waves. We measured focal lengths and spherical aberrations of electrostatic lenses in three independent ways based on contrast data, phase data, or calculations of de Broglie wavefront curvature. We report focal lengths of -2.5 km and -21.7 km with 5% uncertainty for different lenses. All three methods give consistent results. Understanding how lenses magnify and distort atom interference fringes helps improve atom beam velocity measurements made with phase choppers [New J. Phys. 13, 115007 (2011)], which in turn will improve the accuracy of atomic polarizability measurements.

preprint2012arXiv

Measurement of a magic-zero wavelength

Light at a magic-zero wavelength causes zero energy shift for an atom. We measured the longest magic-zero wavelength for ground state potassium atoms to be λzero=768.971(1)λ_\textrm{zero}=768.971(1) nm, and we show how this provides an improved experimental benchmark for atomic structure calculations. This λzeroλ_\textrm{zero} measurement determines the ratio of the potassium atom D1 and D2 line strengths with record precision. It also demonstrates a new application for atom interferometry, and we discuss how decoherence will fundamentally limit future measurements of magic-zero wavelengths.

preprint2010arXiv

Absolute and ratio measurements of the polarizability of Na, K, and Rb with an atom interferometer

We measured the ground state electric dipole polarizability of sodium, potassium, and rubidium using a Mach-Zehnder atom interferometer with an electric field gradient. We find alpha_Na=24.11(2)_stat(18)_sys x 10^-24 cm^3, alpha_K=43.06(14)(33), and alpha_Rb=47.24(12)(42). Since these measurements were all performed in the same apparatus and subject to the same systematic errors we can present polarizability ratios with 0.3% precision. We find alpha_Rb/alpha_Na=1.959(5), alpha_K/alpha_Na=1.786(6), and alpha_Rb/alpha_K=1.097(5). We combine our ratio measurements with the higher precision measurement of sodium polarizability by Ekstrom et al. [Phys. Rev. A 51, 3883 (1995)] to find alpha_K=43.06(21) and alpha_Rb=47.24(21).

preprint2010arXiv

Magic ratio of window width to grating period for Van der Waals potential measurements using material gratings

We report improved precision measurements of the Van der Waals potential strength (C3C_3) for Na atoms and a silicon-nitride (SiNx_x) surface. We studied diffraction from nano-fabricated gratings with a particular "magic" open-fraction that allows us to determine C3C_3 without the need for separate measurements of the width of the grating openings. Therefore, finding the magic open-fraction improves the precision of C3C_3 measurements. The same effect is demonstrated for a grating with an arbitrary open-fraction by rotating it to a particular "magic" angle, yielding C3=3.42±0.19eVA˚3C_3=3.42\pm 0.19 \textrm{eV} \mathring{\textrm{A}}^3 for Na and a SiNx_x surface. This precision is sufficient to detect a change in C3C_3 due to a thin metal coating on the grating surface. We discuss the contribution to C3C_3 of core electrons and edge effects.

preprint2006arXiv

Electron interferometry with nano-gratings

We present an electron interferometer based on near-field diffraction from two nanostructure gratings. Lau fringes are observed with an imaging detector, and revivals in the fringe visibility occur as the separation between gratings is increased from 0 to 3 mm. This verifies that electron beams diffracted by nanostructures remain coherent after propagating farther than the Talbot length zT=2d2/λz_T = 2d^2/λ = 1.2 mm, and hence is a proof of principle for the function of a Talbot-Lau interferometer for electrons. Distorted fringes due to a phase object demonstrates an application for this new type of electron interferometer.

Research graph

See the researcher in context

Open full explorer

Inspect adjacent papers, topics, institutions and collaborators without losing the researcher page.

Building this map preview

BZPEER is loading the nearby papers, people, topics and institutions for this page.