Source author record

Aharon Blank

Aharon Blank appears in the imported research catalog. Authorship, coauthor and topic links are available while profile ownership is still unclaimed.

ResearcherUnclaimed source record

Catalog footprint

What is connected

7works
7topics
4close collaborators

Actions

Connect this record

Log in to claim

Research graph

See the researcher in context

Open full explorer

Inspect adjacent papers, topics, institutions and collaborators without losing the researcher page.

Building this map preview

BZPEER is loading the nearby papers, people, topics and institutions for this page.

Published work

7 published item(s)

preprint2021arXiv

Superconducting microresonators for electron spin resonance, the good, the bad, and the future

The field of electron spin resonance is in constant need to improve its capabilities. Among other things, this means having better resonators which would provide improved spin sensitivity, as well as enable larger microwave magnetic field power conversion factors. Surface micro resonators, made of small metallic patches on a dielectric substrate, provide very good absolute spin sensitivity and high conversion factors due to their very small mode volume. However, such resonators suffer from having a relatively low quality factor, which offsets some of their significant potential advantages. The use of superconducting patches to replace the metallic layer seems like a reasonable and straightforward solution to the quality factor issue, at least for measurements carried out at cryogenic temperatures. Nevertheless, superconducting materials are not easily incorporated into setups requiring high magnetic fields, due to electric current vortices generated in the latter's surface. This makes the transition from normal conducing materials to superconductors highly nontrivial. Here we present the design, fabrication, and testing results of surface micro resonators made of yttrium barium copper oxide (YBCO) superconducting material. We show that with a unique experimental setup, these resonators can be made to operate well even at high fields of about 1.2 T. Furthermore, we analyze the effect of current vortices on the ESR signal and the spins' coherence times. Finally, we provide a head to head comparison of YBCO vs copper resonators of the same dimensions, which clearly shows their pros and cons and directs us to future potential developments and improvements in this field.

preprint2020arXiv

Selective Noise Resistant Gate

Realizing individual control on single qubits in a spin-based quantum register is an ever-increasing challenge due to the close proximity of the qubits resonance frequencies. Current schemes typically suffer from an inherent trade-off between fidelity and qubits selectivity. Here, we report on a new scheme which combines noise protection by dynamical decoupling and magnetic gradient based selectivity, to enhance both the fidelity and the selectivity. With a single nitrogen-vacancy center in diamond, we experimentally demonstrate quantum gates with fidelity = 0.9 $\pm$ 0.02 and a 50 kHz spectral bandwidth, which is almost an order of magnitude narrower than the unprotected bandwidth. Our scheme will enable selective control of an individual nitrogen-vacancy qubit in an interacting qubits array using relatively moderate gradients of about 1 mG/nm.

preprint2014arXiv

High Resolution Microimaging with Pulsed Electrically-Detected Magnetic Resonance

The investigation of paramagnetic species (such as point defects, dopants, and impurities) in solid-state electronic devices is significant because of their effect on device performance. Conventionally, these species are detected and imaged using the electron spin resonance (ESR) technique. In many instances, ESR is not sensitive enough to deal with miniature devices having small numbers of paramagnetic species and high spatial heterogeneity. This limitation can in principle be overcome by employing a more sensitive method called electrically-detected magnetic resonance, which is based on measuring the effect of paramagnetic species on the electric current of the device while inducing electron spin-flip transitions. However, up until now, measurement of the current of the device could not reveal the spatial heterogeneity of its paramagnetic species. We provide here, for the first time, high resolution microimages of paramagnetic species in operating solar cells obtained through electrically-detected magnetic resonance. The method is based on unique microwave pulse sequences for excitation and detection of the electrical signal under a static magnetic field and powerful pulsed magnetic field gradients that spatially encode the electrical current of the sample. The approach developed here can be widely used in the nondestructive three-dimensional inspection and characterization of paramagnetic species in a variety of electronic devices.

preprint2014arXiv

Optically Detected Magnetic Resonance Imaging

Optically detected magnetic resonance (ODMR) provides ultrasensitive means to detect and image a small number of electron and nuclear spins, down to the single spin level with nanoscale resolution. Despite the significant recent progress in this field, it has never been combined with the power of pulsed magnetic resonance imaging (MRI) techniques. Here, we demonstrate for the first time how these two methodologies can be integrated using short pulsed magnetic field gradients to spatially-encode the sample. This results in what we denote as an "optically detected magnetic resonance imaging" (ODMRI) technique. It offers the advantage that the image is acquired in parallel from all parts of the sample, with well-defined three-dimensional point-spread function, and without any loss of spectroscopic information. In addition, this approach may be used in the future for parallel but yet spatially-selective efficient addressing and manipulation of the spins in the sample. Such capabilities are of fundamental importance in the field of quantum spin-based devices and sensors.

preprint2013arXiv

Induction-Detection Electron Spin Resonance with Sensitivity of 1000 Spins: En Route to Scalable Quantum Computations

Spin-based quantum computation (QC) in the solid state is considered to be one of the most promising approaches to scalable quantum computers. However, it faces problems such as initializing the spins, selectively addressing and manipulating single spins, and reading out the state of the individual spins. We have recently sketched a scheme that potentially solves all of these problems5. This is achieved by making use of a unique phosphorus-doped 28Si sample (28Si:P), and applying powerful new electron spin resonance (ESR) techniques for parallel excitation, detection, and imaging in order to implement QCs and efficiently obtain their results. The beauty of our proposed scheme is that, contrary to other approaches, single-spin detection sensitivity is not required and a capability to measure signals of ~100-1000 spins is sufficient to implement it. Here we take the first experimental step towards the actual implementation of such scheme. We show that, by making use of the smallest ESR resonator constructed to date (~5 microns), together with a unique cryogenic amplification scheme and sub-micron imaging capabilities, a sensitivity of less than 1000 electron spin is obtained with spatial resolution of ~500 nm. This is the most sensitive induction-detection experiment carried out to date, and such capabilities put this approach on the fast track to the demonstration of a scalable QC capability.

preprint2013arXiv

Scheme for a spin-based quantum computer employing induction detection and imaging

A theoretical spin-based scheme for performing a variety of quantum computations is presented. It makes use of an array of multiple identical computer vectors of phosphorus-doped silicon where the nuclei serve as logical qubits and the electrons as working qubits. The spins are addressed by a combination of electron spin resonance and nuclear magnetic resonance techniques operating at a field of ~3.3 T and cryogenic temperatures with an ultra-sensitive surface microresonator. Spin initialization is invoked by a combination of strong pre-polarization fields and laser pulses, which shortens the electrons' T1. The set of universal quantum gates for this system includes an arbitrary rotation of single qubits and c-NOT operation in two qubits. The efficient parallel readout of all the spins in the system is performed by high sensitivity induction detection of the electron spin resonance signals with one-dimensional imaging. Details of the suggested scheme are provided, which show that it is scalable to a few hundreds of qubits.

preprint2012arXiv

Nonlinear Induction Detection of Electron Spin Resonance

We present a new approach to the induction detection of electron spin resonance (ESR) signals exploiting the nonlinear properties of a superconducting resonator. Our experiments employ a yttrium barium copper oxide (YBCO) superconducting stripline microwave (MW) resonator integrated with a microbridge. A strong nonlinear response of the resonator is thermally activated in the microbridge when exceeding a threshold in the injected MW power. The responsivity factor characterizing the ESR-induced change in the system's output signal is about 100 times larger when operating the resonator near the instability threshold, compared to the value obtained in the linear regime of operation. Preliminary experimental results, together with a theoretical model of this phenomenon are presented. Under appropriate conditions nonlinear induction detection of ESR can potentially improve upon the current capabilities of conventional linear induction detection ESR.