Source author record

Adrian Zink

Adrian Zink appears in the imported research catalog. Authorship, coauthor and topic links are available while profile ownership is still unclaimed.

ResearcherUnclaimed source record

Catalog footprint

What is connected

3works
2topics
4close collaborators

Actions

Connect this record

Log in to claim

Research graph

See the researcher in context

Open full explorer

Inspect adjacent papers, topics, institutions and collaborators without losing the researcher page.

Building this map preview

BZPEER is loading the nearby papers, people, topics and institutions for this page.

Published work

3 published item(s)

preprint2026arXiv

Mobile Intensity Interferometer for Stellar Observations (MI$^2$SO)

In recent years, intensity interferometry has seen renewed interest and successful application at Imaging Atmospheric Cherenkov Telescope arrays. These measurements are usually performed during bright moon periods while the instruments' primary purpose -- gamma-ray observations -- cannot be fulfilled. The Mobile Intensity Interferometer for Stellar Observations was designed as a proof of concept for a purpose-built intensity interferometer. Using acrylic Fresnel lenses 1 m in diameter with 1.2 m focal length, a compact, economical and lightweight design was realised. The detector fixture allows for translation in the z-axis to adjust for measurements at different wavelengths (and therefore focal points) and easy swapping of the detector in its entirety. Both mobility and scalability in quantity of this design allow for specific targeting of projected baselines and orientations based on the target. Particularly for potential binary systems, selective coverage of a target's u-v plane is essential to probing the characteristics accurately. A first campaign demonstrated the capability of these Fresnel lens telescopes by measuring the spatial coherence curve of Arcturus ($α$ Boo). In an observation time of less than 11 h, the angular diameter was measured with milliarcsecond precision, in agreement with the values in the literature.

preprint2022arXiv

Comparing Different Approaches for Stellar Intensity Interferometry

Stellar intensity interferometers correlate photons within their coherence time and could overcome the baseline limitations of existing amplitude interferometers. Intensity interferometers do not rely on phase coherence of the optical elements and thus function without high grade optics and light combining delay lines. However, the coherence time of starlight observed with realistic optical filter bandwidths (> 0.1 nm) is usually much smaller than the time resolution of the detection system (> 10 ps), resulting in a greatly reduced correlation signal. Reaching high signal to noise in a reasonably short measurement time can be achieved in different ways: either by increasing the time resolution, which increases the correlation signal height, or by increasing the photon rate, which decreases statistical uncertainties of the measurement. We present laboratory measurements employing both approaches and directly compare them in terms of signal to noise ratio. A high time-resolution interferometry setup designed for small to intermediate size optical telescopes and thus lower photon rates (diameters < some meters) is compared to a setup capable of measuring high photon rates, which is planned to be installed at Cherenkov telescopes with dish diameters of > 10 m. We use a Xenon lamp as a common light source simulating starlight. Both setups measure the expected correlation signal and work at the expected shot-noise limit of statistical uncertainties for measurement times between 10 min and 23 h. We discuss the quantitative differences in the measurement results and give an overview of suitable operation regimes for each of the interferometer concepts.

preprint2022arXiv

Design and Performance of the Prototype Schwarzschild-Couder Telescope Camera

The prototype Schwarzschild-Couder Telescope (pSCT) is a candidate for a medium-sized telescope in the Cherenkov Telescope Array. The pSCT is based on a novel dual mirror optics design which reduces the plate scale and allows for the use of silicon photomultipliers as photodetectors. The prototype pSCT camera currently has only the central sector instrumented with 25 camera modules (1600 pixels), providing a 2.68$^{\circ}$ field of view (FoV). The camera electronics are based on custom TARGET (TeV array readout with GSa/s sampling and event trigger) application specific integrated circuits. Field programmable gate arrays sample incoming signals at a gigasample per second. A single backplane provides camera-wide triggers. An upgrade of the pSCT camera is in progress, which will fully populate the focal plane. This will increase the number of pixels to 11,328, the number of backplanes to 9, and the FoV to 8.04$^{\circ}$. Here we give a detailed description of the pSCT camera, including the basic concept, mechanical design, detectors, electronics, current status and first light.