Source author record

Gisela Anton

Gisela Anton appears in the imported research catalog. Authorship, coauthor and topic links are available while profile ownership is still unclaimed.

ResearcherUnclaimed source record

Catalog footprint

What is connected

10works
7topics
4close collaborators

Actions

Connect this record

Log in to claim

Research graph

See the researcher in context

Open full explorer

Inspect adjacent papers, topics, institutions and collaborators without losing the researcher page.

Building this map preview

BZPEER is loading the nearby papers, people, topics and institutions for this page.

Published work

10 published item(s)

preprint2026arXiv

Mobile Intensity Interferometer for Stellar Observations (MI$^2$SO)

In recent years, intensity interferometry has seen renewed interest and successful application at Imaging Atmospheric Cherenkov Telescope arrays. These measurements are usually performed during bright moon periods while the instruments' primary purpose -- gamma-ray observations -- cannot be fulfilled. The Mobile Intensity Interferometer for Stellar Observations was designed as a proof of concept for a purpose-built intensity interferometer. Using acrylic Fresnel lenses 1 m in diameter with 1.2 m focal length, a compact, economical and lightweight design was realised. The detector fixture allows for translation in the z-axis to adjust for measurements at different wavelengths (and therefore focal points) and easy swapping of the detector in its entirety. Both mobility and scalability in quantity of this design allow for specific targeting of projected baselines and orientations based on the target. Particularly for potential binary systems, selective coverage of a target's u-v plane is essential to probing the characteristics accurately. A first campaign demonstrated the capability of these Fresnel lens telescopes by measuring the spatial coherence curve of Arcturus ($α$ Boo). In an observation time of less than 11 h, the angular diameter was measured with milliarcsecond precision, in agreement with the values in the literature.

preprint2022arXiv

Comparing Different Approaches for Stellar Intensity Interferometry

Stellar intensity interferometers correlate photons within their coherence time and could overcome the baseline limitations of existing amplitude interferometers. Intensity interferometers do not rely on phase coherence of the optical elements and thus function without high grade optics and light combining delay lines. However, the coherence time of starlight observed with realistic optical filter bandwidths (> 0.1 nm) is usually much smaller than the time resolution of the detection system (> 10 ps), resulting in a greatly reduced correlation signal. Reaching high signal to noise in a reasonably short measurement time can be achieved in different ways: either by increasing the time resolution, which increases the correlation signal height, or by increasing the photon rate, which decreases statistical uncertainties of the measurement. We present laboratory measurements employing both approaches and directly compare them in terms of signal to noise ratio. A high time-resolution interferometry setup designed for small to intermediate size optical telescopes and thus lower photon rates (diameters < some meters) is compared to a setup capable of measuring high photon rates, which is planned to be installed at Cherenkov telescopes with dish diameters of > 10 m. We use a Xenon lamp as a common light source simulating starlight. Both setups measure the expected correlation signal and work at the expected shot-noise limit of statistical uncertainties for measurement times between 10 min and 23 h. We discuss the quantitative differences in the measurement results and give an overview of suitable operation regimes for each of the interferometer concepts.

preprint2020arXiv

gSeaGen: the KM3NeT GENIE-based code for neutrino telescopes

The gSeaGen code is a GENIE-based application developed to efficiently generate high statistics samples of events, induced by neutrino interactions, detectable in a neutrino telescope. The gSeaGen code is able to generate events induced by all neutrino flavours, considering topological differences between track-type and shower-like events. Neutrino interactions are simulated taking into account the density and the composition of the media surrounding the detector. The main features of gSeaGen are presented together with some examples of its application within the KM3NeT project.

preprint2014arXiv

3D Particle Track Reconstrution in a Single Layer Cadmium-Telluride Hybrid Active Pixel Detector

In the past 20 years the search for neutrinoless double beta decay has driven many developements in all kind of detector technology. A new branch in this field are highly-pixelated semiconductor detectors - such as the CdTe-Timepix detectors. It compromises a cadmium-telluride sensor of 14 mm x 14 mm x 1 mm size with an ASIC which has 256 x 256 pixel of 55 \textmu m pixel pitch and can be used to obtain either spectroscopic or timing information in every pixel. In regular operation it can provide a 2D projection of particle trajectories; however, three dimensional trajectories are desirable for neutrinoless double beta decay and other applications. In this paper we present a method to obtain such trajectories. The method was developed and tested with simulations that assume some minor modifications to the Timepix ASIC. Also, we were able to test the method experimentally and in the best case achieved a position resolution of about 90 \textmu m with electrons of 4.4 GeV.

preprint2014arXiv

Three dimensional photograph of single electron tracks through a scintillator

The reconstruction of particle trajectories makes it possible to distinguish between different types of charged particles. In high-energy physics, where trajectories are rather long, large size trackers must be used to achieve sufficient position resolution. However, in low-background experiments tracks are rather short and three dimensional trajectories could only be resolved in time-projection chambers so far. For detectors of large volume and therefore large drift distances, which are inevitable for low-background experiments, this technique is limited by diffusion of charge carriers. In this work we present a "proof-of-principle" experiment for a new method for the three dimensional tracking of charged particles by scintillation light: We used a setup consisting of a scintillator, mirrors, lenses and a novel imaging device (the hybrid photo detector) in order to image two projections of electron tracks through the scintillator. We took data at the T-24 beam-line at DESY with relativistic electrons with a kinetic energy of 5 GeV and from this data successfully reconstructed their three dimensional propagetion path in the scintillator. With our setup we achieved a position resolution of about 28 mum in the best case.

preprint2013arXiv

Confronting Recent Results from Selected Direct and Indirect Dark Matter Searches and the Higgs Boson with Supersymmetric Models with Non-universal Gaugino Masses

In this paper we study a class of supersymmetric models with non-universal gaugino masses that arise from a mixture of SU(5) singlet and non-singlet representations, i.e. a combination of \textbf{1}, \textbf{24}, \textbf{75} and \textbf{200}. Based on these models we calculate the expected dark matter signatures within the linear combination \textbf{1} $\oplus$ \textbf{24} $\oplus$ \textbf{75} $\oplus$ \textbf{200}. We confront the model predictions with the detected boson as well as current experimental limits from selected indirect and direct dark matter search experiments ANTARES respective IceCube and XENON. We comment on the detection/exclusion capability of the future XENON 1t project. For the investigated parameter span we could not find a SU(5) singlet model that fulfils the Higgs mass and the relic density constraint. In contrary, allowing a mixture of \textbf{1} $\oplus$ \textbf{24} $\oplus$ \textbf{75} $\oplus$ \textbf{200} enables a number of models fulfilling these constraints.

preprint2013arXiv

Simultaneous maximum-likelihood reconstruction for x-ray grating based phase-contrast tomography avoiding intermediate phase retrieval

Phase-wrapping artifacts, statistical image noise and the need for a minimum amount of phase steps per projection limit the practicability of x-ray grating based phase-contrast tomography, when using filtered back projection reconstruction. For conventional x-ray computed tomography, the use of statistical iterative reconstruction algorithms has successfully reduced artifacts and statistical issues. In this work, an iterative reconstruction method for grating based phase-contrast tomography is presented. The method avoids the intermediate retrieval of absorption, differential phase and dark field projections. It directly reconstructs tomographic cross sections from phase stepping projections by the use of a forward projecting imaging model and an appropriate likelihood function. The likelihood function is then maximized with an iterative algorithm. The presented method is tested with tomographic data obtained through a wave field simulation of grating based phase-contrast tomography. The reconstruction results are in agreement with the expectations and proof the validity of the concept.

preprint2012arXiv

Investigation of the signature of lung tissue in X-ray grating-based phase-contrast imaging

Purpose: Grating-based X-ray phase-contrast imaging is a promising modality increasing the soft tissue contrast in medical imaging. In this work, the signature of lung tissue in X-ray grating-based physe-contrast imaging is investigated. Methods: We used a Talbot-Lau interferometer for our investigations of two C57BL/6 mice. Both underwent projection imaging and computed tomography. Results: The results show that the three images obtained by X-ray phase-contrast imaging show complementary anatomical structures. Especially the dark field image allows a more-exact determination of the position of the lung in the chest cavity. Conclusion: Due to its sensitivity to granular structures, the dark field image may be used for the diagnosis of lung diseases in earlier stages or without a CT scan. Furthermore, X-ray phase-contrast imaging may also have great potential in the application of animal laboratory sciences to reduce the number of required animals used in long-term translational, toxicity, and regenerative medicine studies.

preprint2005arXiv

Design considerations and sensitivity estimates for an acoustic neutrino detector

We present a Monte Carlo study of an underwater neutrino telescope based on the detection of acoustic signals generated by neutrino induced cascades. This provides a promising approach to instrument large detector volumes needed to detect the small flux of cosmic neutrinos at ultra-high energies (E > 1 EeV). Acoustic signals are calculated based on the thermo-acoustic model. The signal is propagated to the sensors taking frequency dependent attenuation into account, and detected using a threshold trigger, where acoustic background is included as an effective detection threshold. A simple reconstruction algorithm allows for the determination of the cascade direction and energy. Various detector setups are compared regarding their effective volumes. Sensitivity estimates for the diffuse neutrino flux are presented.

preprint2005arXiv

Development of Acoustic Sensors for the ANTARES Experiment

In order to study the possibility of acoustic detection of ultra-high energy neutrinos in water, our group is planning to deploy and operate an array of acoustic sensors using the ANTARES Neutrino telescope in the Mediterranean Sea. Therefore, acoustic sensor hardware has to be developed which is both capable of operation under the hostile conditions of the deep sea and at the same time provides the high sensitivity necessary to detect the weak pressure signals resulting from the neutrino's interaction in water. In this paper, two different approaches to building such sensors, as well as performance studies in the laboratory and in situ, are presented.