Source author record

Aart J. Nederveen

Aart J. Nederveen appears in the imported research catalog. Authorship, coauthor and topic links are available while profile ownership is still unclaimed.

ResearcherUnclaimed source record

Catalog footprint

What is connected

4works
5topics
4close collaborators

Actions

Connect this record

Log in to claim

Research graph

See the researcher in context

Open full explorer

Inspect adjacent papers, topics, institutions and collaborators without losing the researcher page.

Building this map preview

BZPEER is loading the nearby papers, people, topics and institutions for this page.

Published work

4 published item(s)

preprint2021arXiv

ASL to PET Translation by a Semi-supervised Residual-based Attention-guided Convolutional Neural Network

Positron Emission Tomography (PET) is an imaging method that can assess physiological function rather than structural disturbances by measuring cerebral perfusion or glucose consumption. However, this imaging technique relies on injection of radioactive tracers and is expensive. On the contrary, Arterial Spin Labeling (ASL) MRI is a non-invasive, non-radioactive, and relatively cheap imaging technique for brain hemodynamic measurements, which allows quantification to some extent. In this paper we propose a convolutional neural network (CNN) based model for translating ASL to PET images, which could benefit patients as well as the healthcare system in terms of expenses and adverse side effects. However, acquiring a sufficient number of paired ASL-PET scans for training a CNN is prohibitive for many reasons. To tackle this problem, we present a new semi-supervised multitask CNN which is trained on both paired data, i.e. ASL and PET scans, and unpaired data, i.e. only ASL scans, which alleviates the problem of training a network on limited paired data. Moreover, we present a new residual-based-attention guided mechanism to improve the contextual features during the training process. Also, we show that incorporating T1-weighted scans as an input, due to its high resolution and availability of anatomical information, improves the results. We performed a two-stage evaluation based on quantitative image metrics by conducting a 7-fold cross validation followed by a double-blind observer study. The proposed network achieved structural similarity index measure (SSIM), mean squared error (MSE) and peak signal-to-noise ratio (PSNR) values of $0.85\pm0.08$, $0.01\pm0.01$, and $21.8\pm4.5$ respectively, for translating from 2D ASL and T1-weighted images to PET data. The proposed model is publicly available via https://github.com/yousefis/ASL2PET.

preprint2019arXiv

Compressed Sensing MRI With Variable Density Averaging (CS-VDA) Outperforms Full Sampling At Low SNR

We investigated whether a combination of k-space undersampling and variable density averaging enhances image quality for low-SNR MRI acquisitions. We implemented 3D Cartesian k-space prospective undersampling with a variable number of averages for each k-line. The performance of this compressed sensing with variable-density averaging (CS-VDA) method was evaluated in retrospective analysis of fully sampled phantom MRI measurements, as well as for prospectively accelerated in vivo 3D brain and knee MRI scans. Both phantom and in vivo results showed that acquisitions using the CS-VDA approach resulted in better image quality as compared to full sampling of k-space in the same scan time. Specifically, CS-VDA with a higher number of averages in the center of k-space resulted in the best image quality, apparent from increased anatomical detail with preserved soft-tissue contrast. This novel approach will facilitate improved image quality of inherently low SNR data, such as those with high-resolution or specific contrast-weightings with low SNR efficiency.

preprint2016arXiv

Validation of Continuously Tagged MRI for the Measurement of Dynamic 3D Skeletal Muscle Tissue Deformation

A SPAMM tagged MRI methodology is presented allowing continuous (3.3-3.6 Hz) sampling of 3D dynamic soft tissue deformation using non-segmented 3D acquisitions. The 3D deformation is reconstructed by the combination of 3 mutually orthogonal tagging directions, thus requiring only 3 repeated motion cycles. In addition a fully automatic post-processing framework is presented employing Gabor scale-space and filter-bank analysis for tag extrema segmentation and triangulated surface fitting aided by Gabor filter bank derived surface normals. Deformation is derived following tracking of tag surface triplet triangle intersections. The dynamic deformation measurements were validated using indentation tests (~20 mm deep at 12 mm/s) on a silicone gel soft tissue phantom containing contrasting markers which provide a reference measure of deformation. In addition, the techniques were evaluated in-vivo for dynamic skeletal muscle tissue deformation measurement during indentation of the biceps region of the upper arm in a volunteer.

preprint2016arXiv

Validation of SPAMM Tagged MRI Based Measurement of 3D Soft Tissue Deformation

This study presents and validates a novel (non-ECG-triggered) MRI sequence based on SPAtial Modulation of the Magnetization (SPAMM) to non-invasively measure 3D (quasi-static) soft tissue deformations using only six acquisitions (three static and three indentations). In current SPAMM tagged MRI approaches data is typically constructed from many repeated motion cycles. This has so far restricted its application to the measurement of highly repeatable and periodic movements (e.g. cardiac deformation). In biomechanical applications where soft tissue deformation is artificially induced, often by indentation, significant repeatability constraints exist and, for clinical applications, discomfort and health issues generally preclude a large number of repetitions.