Source author record

Kevin M. Moerman

Kevin M. Moerman appears in the imported research catalog. Authorship, coauthor and topic links are available while profile ownership is still unclaimed.

ResearcherUnclaimed source record

Catalog footprint

What is connected

5works
4topics
4close collaborators

Actions

Connect this record

Log in to claim

Research graph

See the researcher in context

Open full explorer

Inspect adjacent papers, topics, institutions and collaborators without losing the researcher page.

Building this map preview

BZPEER is loading the nearby papers, people, topics and institutions for this page.

Published work

5 published item(s)

preprint2016arXiv

Digital image correlation and finite element modelling as a method to determine mechanical properties of human soft tissue in vivo

The mechanical properties of human soft tissue are crucial for impact biomechanics, rehabilitation engineering and surgical simulation. Validation of these constitutive models using human data remains challenging and often requires the use of non-invasive imaging and inverse finite element (FE) analysis. Post processing data from imaging methods such as tagged magnetic resonance imaging (MRI) can be challenging. Digital Image Correlation (DIC) however is a relatively straightforward imaging method and thus the goal of this study was to assess the use of DIC in combination with FE modelling to determine the bulk material properties of human soft tissue. Indentation experiments were performed on a silicone gel soft tissue phantom. A two camera DIC setup was then used to record the 3D surface deformation. The experiment was then simulated using a FE model.

preprint2016arXiv

On Advantages of the Kelvin Mapping in Finite Element Implementations of Deformation Processes

Classical continuum mechanical theories operate on three-dimensional Eu-clidian space using scalar, vector, and tensor-valued quantities usually up to the order of four. For their numerical treatment, it is common practice to transform the relations into a matrix-vector format. This transformation is usually performed using the so-called Voigt mapping. This mapping does not preserve tensor character leaving significant room for error as stress and strain quantities follow from different mappings and thus have to be treated differently in certain mathematical operations. Despite its conceptual and notational difficulties having been pointed out, the Voigt mapping remains the foundation of most current finite element programmes. An alternative is the so-called Kelvin mapping which has recently gained recognition in studies of theoretical mechanics. This article is concerned with benefits of the Kelvin mapping in numerical modelling tools such as finite element software. The decisive difference to the Voigt mapping is that Kelvin's method preserves tensor character, and thus the numerical matrix notation directly corresponds to the original tensor notation. Further benefits in numerical implementations are that tensor norms are calculated identically without distinguishing stress or strain-type quantities and tensor equations can be directly transformed into matrix equations without additional considerations. The only implementational changes are related to a scalar factor in certain finite element matrices and hence, harvesting the mentioned benefits comes at very little cost.

preprint2016arXiv

Validation of Continuously Tagged MRI for the Measurement of Dynamic 3D Skeletal Muscle Tissue Deformation

A SPAMM tagged MRI methodology is presented allowing continuous (3.3-3.6 Hz) sampling of 3D dynamic soft tissue deformation using non-segmented 3D acquisitions. The 3D deformation is reconstructed by the combination of 3 mutually orthogonal tagging directions, thus requiring only 3 repeated motion cycles. In addition a fully automatic post-processing framework is presented employing Gabor scale-space and filter-bank analysis for tag extrema segmentation and triangulated surface fitting aided by Gabor filter bank derived surface normals. Deformation is derived following tracking of tag surface triplet triangle intersections. The dynamic deformation measurements were validated using indentation tests (~20 mm deep at 12 mm/s) on a silicone gel soft tissue phantom containing contrasting markers which provide a reference measure of deformation. In addition, the techniques were evaluated in-vivo for dynamic skeletal muscle tissue deformation measurement during indentation of the biceps region of the upper arm in a volunteer.

preprint2016arXiv

Validation of SPAMM Tagged MRI Based Measurement of 3D Soft Tissue Deformation

This study presents and validates a novel (non-ECG-triggered) MRI sequence based on SPAtial Modulation of the Magnetization (SPAMM) to non-invasively measure 3D (quasi-static) soft tissue deformations using only six acquisitions (three static and three indentations). In current SPAMM tagged MRI approaches data is typically constructed from many repeated motion cycles. This has so far restricted its application to the measurement of highly repeatable and periodic movements (e.g. cardiac deformation). In biomechanical applications where soft tissue deformation is artificially induced, often by indentation, significant repeatability constraints exist and, for clinical applications, discomfort and health issues generally preclude a large number of repetitions.

preprint2015arXiv

Control of Tension-Compression Asymmetry in Ogden Hyperelasticity with Application to Soft Tissue Modelling

This paper discusses tension-compression asymmetry properties of Ogden hyperelastic formulations. It is shown that if all negative or all positive Ogden coefficients are used, tension-compression asymmetry occurs the degree of which cannot be separately controlled from the degree of non-linearity. A simple hybrid form is therefore proposed providing separate control over the tension-compression asymmetry. It is demonstrated how this form relates to a newly introduced generalised strain tensor class which encompasses both the tension-compression asymmetric Seth-Hill strain class and the tension-compression symmetric Bažant strain class. If the control parameter is set to q=0.5 a tension-compression symmetric form involving Bažant strains is obtained with the property Ψ(λ_1,λ_2,λ_3 )=Ψ(1/λ_1 ,1/λ_2 ,1/λ_3 ). The symmetric form may be desirable for the definition of ground matrix contributions in soft tissue modelling allowing all deviation from the symmetry to stem solely from fibrous reinforcement. Such an application is also presented demonstrating the use of the proposed formulation in the modelling of the non-linear elastic and transversely isotropic behaviour of skeletal muscle tissue in compression (the model implementation and fitting procedure have been made freely available). The presented hyperelastic formulations may aid researchers in independently controlling the degree of tension-compression asymmetry from the degree of non-linearity, and in the case of anisotropic materials may assist in determining the role played by, either the ground matrix, or the fibrous reinforcing structures, in generating asymmetry.