Source author record

A. S. Kiyumbi

A. S. Kiyumbi appears in the imported research catalog. Authorship, coauthor and topic links are available while profile ownership is still unclaimed.

ResearcherUnclaimed source record

Catalog footprint

What is connected

1works
2topics
1close collaborators

Actions

Connect this record

Log in to claim

Research graph

See the researcher in context

Open full explorer

Inspect adjacent papers, topics, institutions and collaborators without losing the researcher page.

Building this map preview

BZPEER is loading the nearby papers, people, topics and institutions for this page.

Published work

1 published item(s)

preprint2026arXiv

An effective microscopic model for plasmonic sensing of malaria

Malaria remains a major health threat in low-resource regions and rapid diagnostic tests often lack the sensitivity required for early detection. To address this and help establish more sensitive testing devices, we develop a predictive microscopic model for plasmonic biosensing using metasurfaces. Specifically, we consider the detection of plasmodium lactate dehydrogenase (pLDH), a well-known malaria biomarker. An example metasurface is studied to showcase the effective microscopic model - it consists of a gold nanohole array (150nm film; 150nm diameter; 400nm period) and the biochemistry above it is modelled as stacks of closely packed adlayers. Using Maxwell Garnett effective medium theory we link the refractive index of the pLDH biomarker adsorbed layer on top of the metasurface to the bulk concentration of pLDH in the buffer. This effective microscopic model accounts for the combined optical properties of the biochemistry matrix, bound pLDH and the buffer medium. By simulating the sensor using the finite element method and an approximate analytical method, we show that the effective model allows one to determine the sensor response, predict binding interactions, and quantify concentration changes on the sensor surface. We then calculate the sensor sensitivity for our example metasurface and its theoretical limit of detection (LOD). The lowest LOD calculated based on the model is 0.02nM of pLDH, equivalent to 0.7ng/mL, which is a 30 times improvement over current rapid diagnostic tests. While this improvement in performance is highly promising, further work on transferring the ideal theory developed here to field-tested empirical performance will be required. The effective microscopic model we introduce is quite general and the framework developed offers a broadly applicable tool for the design and optimization of other types of highly sensitive plasmonic biosensors.