Researcher profile

M. S. Tame

M. S. Tame contributes to research discovery and scholarly infrastructure.

ResearcherAffiliation not importedOpen to collaborate

Trust snapshot

Quick read

Trust 19 - UnverifiedVerification L1Unclaimed author
5works
0followers
3topics
4close collaborators

Actions

Decide how to stay connected

Follow researcher0

Identity and collaboration

How to connect with this researcher

Claiming links this public author record to a researcher profile and unlocks direct collaboration workflows.

Log in to claim

Direct collaboration

Open a focused conversation when the fit is right

Claim this author entity first to unlock direct invitations.

Research graph

See the researcher in context

Open full explorer

Inspect adjacent work, topics, institutions and collaborators without jumping out to a separate graph page.

Building this graph slice

BZPEER is loading the nearby papers, people, topics and institutions for this page.

Published work

5 published item(s)

preprint2026arXiv

An effective microscopic model for plasmonic sensing of malaria

Malaria remains a major health threat in low-resource regions and rapid diagnostic tests often lack the sensitivity required for early detection. To address this and help establish more sensitive testing devices, we develop a predictive microscopic model for plasmonic biosensing using metasurfaces. Specifically, we consider the detection of plasmodium lactate dehydrogenase (pLDH), a well-known malaria biomarker. An example metasurface is studied to showcase the effective microscopic model - it consists of a gold nanohole array (150nm film; 150nm diameter; 400nm period) and the biochemistry above it is modelled as stacks of closely packed adlayers. Using Maxwell Garnett effective medium theory we link the refractive index of the pLDH biomarker adsorbed layer on top of the metasurface to the bulk concentration of pLDH in the buffer. This effective microscopic model accounts for the combined optical properties of the biochemistry matrix, bound pLDH and the buffer medium. By simulating the sensor using the finite element method and an approximate analytical method, we show that the effective model allows one to determine the sensor response, predict binding interactions, and quantify concentration changes on the sensor surface. We then calculate the sensor sensitivity for our example metasurface and its theoretical limit of detection (LOD). The lowest LOD calculated based on the model is 0.02nM of pLDH, equivalent to 0.7ng/mL, which is a 30 times improvement over current rapid diagnostic tests. While this improvement in performance is highly promising, further work on transferring the ideal theory developed here to field-tested empirical performance will be required. The effective microscopic model we introduce is quite general and the framework developed offers a broadly applicable tool for the design and optimization of other types of highly sensitive plasmonic biosensors.

preprint2022arXiv

Experimental measurement of kinetic parameters using quantum plasmonic sensing

Kinetic models are essential for describing how molecules interact in a variety of biochemical processes. The estimation of a model's kinetic parameters by experiment enables researchers to understand how pathogens, such as viruses, interact with other entities like antibodies and trial drugs. In this work, we report a simple proof-of-principle experiment that uses quantum sensing techniques to give a more precise estimation of kinetic parameters than is possible with a classical approach. The interaction we study is that of bovine serum albumin (BSA) binding to gold via an electrostatic mechanism. BSA is an important protein in biochemical research as it can be conjugated with other proteins and peptides to create sensors with a wide range of specificity. We use single photons generated via parametric down-conversion to probe the BSA-gold interaction in a plasmonic resonance sensor. We find that sub-shot-noise level fluctuations in the sensor signal allow us to achieve an improvement in the precision of up to 31.8% for the values of the kinetic parameters. This enhancement can in principle be further increased in the setup. Our work highlights the potential use of quantum states of light for sensing in biochemical research.

preprint2022arXiv

Measurement of binding kinetics using quantum plasmonic resonance sensing applied to HIV-1

The work done in this paper is an extension of the work done by Mpofu et al in [1]. The motivation for this paper is to show the potential of quantum bio-sensing techniques in applications to complex viruses like the human immunodeficiency virus (HIV) and to show it's potential in binding reactions where the signal is small and can potentially be buried in noise. In this paper we show theoretically that using quantum states of light such as the Fock state improves the precision in the estimation of kinetic parameters measured from the sensorgrams produced by the Kretschmann conguration. Though the Fock state is not the only quantum state in this study we look only at the Fock state because it has been shown to be the state which offers the best enhancement [1]. We show here that the Fock state allows us to measure the parameters more accurately in comparison to the classical (Coherent) state of light. We consider in this paper a binding reaction involving HIV type 1 (HIV-1). Specifically we look at the binding reaction between a variant of HIV-1 protease and nelnavir which is an inhibitor. Such a study is also offers value for drug discovery research as it points to the development of new technologies which can be applied to testing the efficacy of new drugs. Quantum technologies can prove to be useful in the fight against the HIV pandemic and assist in the continual research towards the development of treatments and a cure.

preprint2022arXiv

Measuring kinetic parameters using quantum plasmonic sensing

The measurement of parameters that describe kinetic processes is important in the study of molecular interactions. It enables a deeper understanding of the physical mechanisms underlying how different biological entities interact with each other, such as viruses with cells, vaccines with antibodies, or new drugs with specific diseases. In this work, we study theoretically the use of quantum sensing techniques for measuring the kinetic parameters of molecular interactions. The sensor we consider is a plasmonic resonance sensor -- a label-free photonic sensor that is one of the most widely used in research and industry. The first type of interaction we study is the antigen BSA interacting with antibody IgG1, which provides a large sensor response. The second type is the enzyme carbonic anhydrase interacting with the tumor growth inhibitor benzenesulfonamide, which produces a small sensor response. For both types of interaction we consider the use of two-mode Fock states, squeezed vacuum states and squeezed displaced states. We find that these quantum states offer an enhancement in the measurement precision of kinetic parameters when compared to that obtained with classical light. The results may help in the design of more precise quantum-based sensors for studying kinetics in the life sciences.

preprint2020arXiv

Experimental investigation of Markovian and non-Markovian channel addition

The study of memory effects in quantum channels helps in developing characterization methods for open quantum systems and strategies for quantum error correction. Two main sets of channels exist, corresponding to system dynamics with no memory (Markovian) and with memory (non-Markovian). Interestingly, these sets have a non-convex geometry, allowing one to form a channel with memory from the addition of memoryless channels and vice-versa. Here, we experimentally investigate this non-convexity in a photonic setup by subjecting a single qubit to a convex combination of Markovian and non-Markovian channels. We use both divisibility and distinguishability as criteria for the classification of memory effects, with associated measures. Our results highlight some practical considerations that may need to be taken into account when using memory criteria to study system dynamics given by the addition of Markovian and non-Markovian channels in experiments.