Source author record

A. Ranieri

A. Ranieri appears in the imported research catalog. Authorship, coauthor and topic links are available while profile ownership is still unclaimed.

ResearcherUnclaimed source record

Catalog footprint

What is connected

28works
3topics
4close collaborators

Actions

Connect this record

Log in to claim

Research graph

See the researcher in context

Open full explorer

Inspect adjacent papers, topics, institutions and collaborators without losing the researcher page.

Building this map preview

BZPEER is loading the nearby papers, people, topics and institutions for this page.

Published work

28 published item(s)

preprint2022arXiv

Quality Control of Mass-Produced GEM Detectors for the CMS GE1/1 Muon Upgrade

The series of upgrades to the Large Hadron Collider, culminating in the High Luminosity Large Hadron Collider, will enable a significant expansion of the physics program of the CMS experiment. However, the accelerator upgrades will also make the experimental conditions more challenging, with implications for detector operations, triggering, and data analysis. The luminosity of the proton-proton collisions is expected to exceed $2-3\times10^{34}$~cm$^{-2}$s$^{-1}$ for Run 3 (starting in 2022), and it will be at least $5\times10^{34}$~cm$^{-2}$s$^{-1}$ when the High Luminosity Large Hadron Collider is completed for Run 4. These conditions will affect muon triggering, identification, and measurement, which are critical capabilities of the experiment. To address these challenges, additional muon detectors are being installed in the CMS endcaps, based on Gas Electron Multiplier technology. For this purpose, 161 large triple-Gas Electron Multiplier detectors have been constructed and tested. Installation of these devices began in 2019 with the GE1/1 station and will be followed by two additional stations, GE2/1 and ME0, to be installed in 2023 and 2026, respectively. The assembly and quality control of the GE1/1 detectors were distributed across several production sites around the world. We motivate and discuss the quality control procedures that were developed to standardize the performance of the detectors, and we present the final results of the production. Out of 161 detectors produced, 156 detectors passed all tests, and 144 detectors are now installed in the CMS experiment. The various visual inspections, gas tightness tests, intrinsic noise rate characterizations, and effective gas gain and response uniformity tests allowed the project to achieve this high success rate.

preprint2021arXiv

Modeling the triple-GEM detector response to background particles for the CMS Experiment

An estimate of environmental background hit rate on triple-GEM chambers is performed using Monte Carlo (MC) simulation and compared to data taken by test chambers installed in the CMS experiment (GE1/1) during Run-2 at the Large Hadron Collider (LHC). The hit rate is measured using data collected with proton-proton collisions at 13 TeV and a luminosity of 1.5$\times10^{34}$ cm$^{-2}$ s$^{-1}$. The simulation framework uses a combination of the FLUKA and Geant4 packages to obtain the hit rate. FLUKA provides the radiation environment around the GE1/1 chambers, which is comprised of the particle flux with momentum direction and energy spectra ranging from $10^{-11}$ to $10^{4}$ MeV for neutrons, $10^{-3}$ to $10^{4}$ MeV for $γ$'s, $10^{-2}$ to $10^{4}$ MeV for $e^{\pm}$, and $10^{-1}$ to $10^{4}$ MeV for charged hadrons. Geant4 provides an estimate of detector response (sensitivity) based on an accurate description of detector geometry, material composition and interaction of particles with the various detector layers. The MC simulated hit rate is estimated as a function of the perpendicular distance from the beam line and agrees with data within the assigned uncertainties of 10-14.5%. This simulation framework can be used to obtain a reliable estimate of background rates expected at the High Luminosity LHC.

preprint2020arXiv

Interstrip Capacitances of the Readout Board used in Large Triple-GEM Detectors for the CMS Muon Upgrade

We present analytical calculations, Finite Element Analysis modeling, and physical measurements of the interstrip capacitances for different potential strip geometries and dimensions of the readout boards for the GE2/1 triple-Gas Electron Multiplier detector in the CMS muon system upgrade. The main goal of the study is to find configurations that minimize the interstrip capacitances and consequently maximize the signal-to-noise ratio for the detector. We find agreement at the 1.5--4.8% level between the two methods of calculations and on the average at the 17% level between calculations and measurements. A configuration with halved strip lengths and doubled strip widths results in a measured 27--29% reduction over the original configuration while leaving the total number of strips unchanged. We have now adopted this design modification for all eight module types of the GE2/1 detector and will produce the final detector with this new strip design.

preprint2016arXiv

Limit on the production of a new vector boson in $\mathrm{e^+ e^-}\rightarrow {\rm U}γ$, U$\rightarrow π^+π^-$ with the KLOE experiment

The recent interest in a light gauge boson in the framework of an extra U(1) symmetry motivates searches in the mass range below 1 GeV. We present a search for such a particle, the dark photon, in ${\rm e^+ e^-}\rightarrow {\rm U}γ$, U$\rightarrow π^+π^-$ based on 28 million $\mathrm{e^+ e^-} \rightarrow π^+ π^-γ$ events collected at DA$Φ$NE by the KLOE experiment. The $π^+ π^-$ production by initial-state radiation compensates for a loss of sensitivity of previous KLOE ${\rm U} \rightarrow \mathrm{e^+ e^-}$, $μ^+μ^-$ searches due to the small branching ratios in the $ρ-ω$ resonance region. We found no evidence for a signal and set a limit at 90\% CL on the mixing strength between the photon and the dark photon, $\varepsilon^2$, in the U mass range between $527$ and $987$~MeV. Above 700 MeV this new limit is more stringent than previous ones.

preprint2016arXiv

Measurement of the $ϕ\to π^0 e^+e^-$ transition form factor with the KLOE detector

A measurement of the vector to pseudoscalar conversion decay $ϕ\to π^0 e^+e^-$ with the KLOE experiment is presented. A sample of $\sim 9500$ signal events was selected from a data set of 1.7 fb$^{-1}$ of $e^+e^-$ collisions at $\sqrt{s} \sim m_ϕ$ collected at the DA$Φ$NE $e^+e^-$ collider. These events were used to obtain the first measurement of the transition form factor $| F_{ϕπ^0}(q^2) |$ and a new measurement of the branching ratio of the decay: $\rm{BR}\,(ϕ\to π^0 e^+e^-) = (\,1.35 \pm 0.05^{\,\,+0.05}_{\,\,-0.10}\,) \times 10 ^{-5}$. The result improves significantly on previous measurements and is in agreement with theoretical predictions.

preprint2016arXiv

Precision measurement of the $η\toπ^+π^-π^0$ Dalitz plot distribution with the KLOE detector

Using $1.6$ fb$^{-1}$ of $e^+ e^-\toϕ\toηγ$ data collected with the KLOE detector at DA$Φ$NE, the Dalitz plot distribution for the $η\to π^+ π^- π^0$ decay is studied with the world's largest sample of $\sim 4.7 \cdot 10^6$ events. The Dalitz plot density is parametrized as a polynomial expansion up to cubic terms in the normalized dimensionless variables $X$ and $Y$. The experiment is sensitive to all charge conjugation conserving terms of the expansion, including a $gX^2Y$ term. The statistical uncertainty of all parameters is improved by a factor two with respect to earlier measurements.

preprint2015arXiv

A novel application of Fiber Bragg Grating (FBG) sensors in MPGD

We present a novel application of Fiber Bragg Grating (FBG) sensors in the construction and characterisation of Micro Pattern Gaseous Detector (MPGD), with particular attention to the realisation of the largest triple (Gas electron Multiplier) GEM chambers so far operated, the GE1/1 chambers of the CMS experiment at LHC. The GE1/1 CMS project consists of 144 GEM chambers of about 0.5 m2 active area each, employing three GEM foils per chamber, to be installed in the forward region of the CMS endcap during the long shutdown of LHC in 2108-2019. The large active area of each GE1/1 chamber consists of GEM foils that are mechanically stretched in order to secure their flatness and the consequent uniform performance of the GE1/1 chamber across its whole active surface. So far FBGs have been used in high energy physics mainly as high precision positioning and re-positioning sensors and as low cost, easy to mount, low space consuming temperature sensors. FBGs are also commonly used for very precise strain measurements in material studies. In this work we present a novel use of FBGs as flatness and mechanical tensioning sensors applied to the wide GEM foils of the GE1/1 chambers. A network of FBG sensors have been used to determine the optimal mechanical tension applied and to characterise the mechanical tension that should be applied to the foils. We discuss the results of the test done on a full-sized GE1/1 final prototype, the studies done to fully characterise the GEM material, how this information was used to define a standard assembly procedure and possible future developments.

preprint2015arXiv

Limit on the production of a low-mass vector boson in $\mathrm{e}^{+}\mathrm{e}^{-} \to \mathrm{U}γ$, $\mathrm{U} \to \mathrm{e}^{+}\mathrm{e}^{-}$ with the KLOE experiment

The existence of a new force beyond the Standard Model is compelling because it could explain several striking astrophysical observations which fail standard interpretations. We searched for the light vector mediator of this dark force, the $\mathrm{U}$ boson, with the KLOE detector at the DA$Φ$NE $\mathrm{e}^{+}\mathrm{e}^{-}$ collider. Using an integrated luminosity of 1.54 fb$^{-1}$, we studied the process $\mathrm{e}^{+}\mathrm{e}^{-} \to \mathrm{U}γ$, with $\mathrm{U} \to \mathrm{e}^{+}\mathrm{e}^{-}$, using radiative-return to search for a resonant peak in the dielectron invariant-mass distribution. We did not find evidence for a signal, and set a 90\%~CL upper limit on the mixing strength between the Standard Model photon and the dark photon, $\varepsilon^2$, at $10^{-6}$--$10^{-4}$ in the 5--520~MeV/c$^2$ mass range.

preprint2014arXiv

Performance of a Large-Area GEM Detector Prototype for the Upgrade of the CMS Muon Endcap System

Gas Electron Multiplier (GEM) technology is being considered for the forward muon upgrade of the CMS experiment in Phase 2 of the CERN LHC. Its first implementation is planned for the GE1/1 system in the $1.5 < \midη\mid < 2.2$ region of the muon endcap mainly to control muon level-1 trigger rates after the second long LHC shutdown. A GE1/1 triple-GEM detector is read out by 3,072 radial strips with 455 $μ$rad pitch arranged in eight $η$-sectors. We assembled a full-size GE1/1 prototype of 1m length at Florida Tech and tested it in 20-120 GeV hadron beams at Fermilab using Ar/CO$_{2}$ 70:30 and the RD51 scalable readout system. Four small GEM detectors with 2-D readout and an average measured azimuthal resolution of 36 $μ$rad provided precise reference tracks. Construction of this largest GEM detector built to-date is described. Strip cluster parameters, detection efficiency, and spatial resolution are studied with position and high voltage scans. The plateau detection efficiency is [97.1 $\pm$ 0.2 (stat)]\%. The azimuthal resolution is found to be [123.5 $\pm$ 1.6 (stat)] $μ$rad when operating in the center of the efficiency plateau and using full pulse height information. The resolution can be slightly improved by $\sim$ 10 $μ$rad when correcting for the bias due to discrete readout strips. The CMS upgrade design calls for readout electronics with binary hit output. When strip clusters are formed correspondingly without charge-weighting and with fixed hit thresholds, a position resolution of [136.8 $\pm$ 2.5 stat] $μ$rad is measured, consistent with the expected resolution of strip-pitch/$\sqrt{12}$ = 131.3 $μ$rad. Other $η$-sectors of the detector show similar response and performance.

preprint2014arXiv

Study of Dalitz decay phi -> eta e+e- with KLOE detector

We have studied the vector to pseudoscalar conversion decay phi -> eta e+e-, with eta -> pi0pi0pi0, with the KLOE detector at DAPHNE. The data set of 1.7 fb-1 of e+e- collisions at sqrt(s)~Mphi contains a clear conversion decay signal of ~31,000 events from which we measured a value of BR(phi -> eta e+e-)=(1.075+-0.007+-0.038)x10-4. The same sample is used to determine the transition form factor by a fit to the e+e- invariant mass spectrum, obtaining b(phi eta) =(1.17 +- 0.10 + 0.07) GeV-2, that improves by a factor of five the precision of the previous measurement and is in good agreement with VMD expectations.

preprint2014arXiv

Test of CPT and Lorentz symmetry in entangled neutral kaons with the KLOE experiment

Neutral kaon pairs produced in phi decays in anti-symmetric entangled state can be exploited to search for violation of CPT symmetry and Lorentz invariance. We present an analysis of the CP-violating process phi->K_S K_L->pi+pi-pi+pi- based on 1.7 fb-1 of data collected by the KLOE experiment at the Frascati phi-factory DAFNE. The data are used to perform a measurement of the CPT-violating parameters Delta_amu for neutral kaons in the contest of the Standard Model Extension framework. The parameters measured in the reference frame of the fixed stars are: Delta_ao = (-6.0 +- 7.7_{stat} +- 3.1_{syst}) x 10^{-18} GeV Delta_ax = ( 0.9 +- 1.5_{stat} +- 0.6_{syst}) x 10^{-18} GeV Delta_ay = (-2.0 +- 1.5_{stat} +- 0.5_{syst}) x 10^{-18} GeV Delta_az = ( 3.1 +- 1.7_{stat} +- 0.5_{syst}) x 10^{-18} GeV These are presently the most precise measurements in the quark sector of the Standard Model Extension.

preprint2013arXiv

A new limit on the CP violating decay KS -> 3pi0 with the KLOE experiment

We have carried out a new direct search for the CP violating decay KS -> 3pi0 with 1.7 fb^-1 of e+e- collisions collected by the KLOE detector at the phi-factory DAFNE. We have searched for this decay in a sample of about 5.9 x 10^8 KS KL events tagging the KS by means of the KL interaction in the calorimeter and requiring six prompt photons. With respect to our previous search, the analysis has been improved by increasing of a factor four the tagged sample and by a more effective background rejection of fake KS tags and spurious clusters. We find no candidates in data and simulated background samples, while we expect 0.12 standard model events. Normalizing to the number of KS -> 2pi0 events in the same sample, we set the upper limit on BR(KS -> 3pi0 < 2.6 x 10^-8 at 90% C.L., five times lower than the previous limit. We also set the upper limit on the eta_000 parameter, |eta_000 | < 0.0088 at 90% C.L., improving by a factor two the latest direct measurement.

preprint2013arXiv

Limit on the production of a light vector gauge boson in phi meson decays with the KLOE detector

We present a new limit on the production of a light dark-force mediator with the KLOE detector at DAPHNE. This boson, called U, has been searched for in the decay phi --> eta U, U --> e+ e-, analyzing the decay eta --> pi0 pi0 pi0 in a data sample of 1.7 fb-1. No structures are observed in the e+e- invariant mass distribution over the background. This search is combined with a previous result obtained from the decay eta --> pi+ pi- pi0, increasing the sensitivity. We set an upper limit at 90% C.L. on the ratio between the U boson coupling constant and the fine structure constant of alpha'/alpha < 1.7x10^-5 for 30<M_U<400 MeV and alpha'/alpha < 8x10^-6 for the sub-region 50<M_U<210 MeV. This result assumes the Vector Meson Dominance expectations for the phietagamma^* transition form factor. The dependence of this limit on the transition form factor has also been studied.

preprint2013arXiv

Precision measurement of $σ(e^+e^-\rightarrowπ^+π^-γ)/σ(e^+e^-\rightarrow μ^+μ^-γ)$ and determination of the $π^+π^-$ contribution to the muon anomaly with the KLOE detector

We have measured the ratio $σ(e^+e^-\rightarrowπ^+π^-γ)/σ(e^+e^-\rightarrow μ^+μ^-γ)$, with the KLOE detector at DA$Φ$NE for a total integrated luminosity of $\sim$ 240 pb$^{-1}$. From this ratio we obtain the cross section $σ(e^+e^-\rightarrowπ^+π^-)$. From the cross section we determine the pion form factor $|F_π|^2$ and the two-pion contribution to the muon anomaly $a_μ$ for $0.592<M_{ππ}<0.975$ GeV, $Δ^{ππ} a_μ$= $({\rm 385.1\pm1.1_{stat}\pm2.7_{sys+theo}})\times10^{-10}$. This result confirms the current discrepancy between the Standard Model calculation and the experimental measurement of the muon anomaly.

preprint2013arXiv

Recent results on hadron physics at KLOE

One of the basic motivations of the KLOE and KLOE-2 collaborations is the test of fundamental symmetries and the search for phenomena beyond the Standard Model via the hadronic and leptonic decays of ground-state mesons and via their production in the fusion of virtual gamma quanta exchanged between colliding electrons and positrons. This contribution includes brief description of results of recent analysis of the KLOE data aimed at (i) the search for the dark matter boson, (ii) determination of the hadronic and light-by-light contributions to the g-2 muon anomaly and (iii) tests of QCD anomalies.

preprint2012arXiv

Measurement of Γ(η-> π^+π^-γ)/Γ(η-> π^+π^-π^0) with the KLOE Detector

The ratio R_η=Γ(η-> π^+π^-γ)/Γ(η-> π^+π^-π^0) has been measured by analyzing 22 million ϕ\to ηγdecays collected by the KLOE experiment at DA\PhiNE, corresponding to an integrated luminosity of 558 pb^{-1}. The η\to π^+π^-γproceeds both via the ρresonant contribution, and possibly a non-resonant direct term, connected to the box anomaly. Our result, R_η= 0.1856\pm 0.0005_{stat} \pm 0.0028_{syst}, points out a sizable contribution of the direct term to the total width. The di-pion invariant mass for the η-> π^+π^-γdecay could be described in a model-independent approach in terms of a single free parameter, α. The determined value of the parameter αis α= (1.32 \pm 0.08_{stat} +0.10/-0.09_{syst}\pm 0.02_{theo}) GeV^{-2}

preprint2012arXiv

Measurement of η meson production in γγ interactions and Γ(η-->γγ) with the KLOE detector

We present a measurement of η meson production in photon-photon interactions produced by electron-positron beams colliding with \sqrt{s}=1 GeV. The measurement is done with the KLOE detector at the ϕ-factory DAΦNE with an integrated luminosity of 0.24 fb^{-1}. The e^+e^- --> e^+e^-η cross section is measured without detecting the outgoing electron and positron, selecting the decays η-->π^+π^-π^0 and η-->π^0π^0π^0. The most relevant background is due to e^+e^- --> ηγ when the monochromatic photon escapes detection. The cross section for this process is measured as σ(e^+e^- -->ηγ) = (856 \pm 8_{stat} \pm 16_{syst}) pb. The combined result for the e^+e^- -->e^+e^-η cross section is σ(e^+e^- -->e^+e^-η) = (32.72 \pm 1.27_{stat} \pm 0.70_{syst}) pb. From this we derive the partial width Γ(η-->γγ) = (520 \pm 20_{stat} \pm 13_{syst}) eV. This is in agreement with the world average and is the most precise measurement to date.

preprint2011arXiv

$γγ$ physics with the KLOE experiment

The processes $e^+e^-\to e^+e^-X$, with $X$ being either the $η$ meson or $π^0π^0$, are studied at DA$Φ$NE, with $e^+e^-$ beams colliding at $\sqrt{s}\simeq1$ GeV, below the $ϕ$ resonance peak. The data sample is from an integrated luminosity of 240 pb$^{-1}$, collected by the KLOE experiment without tagging of the outgoing $e^+e^-$. Preliminary results are presented on the observation of the $γγ\toη$ process, with both $η\toπ^+π^-π^0$ and $η\toπ^0π^0π^0$ channels, and the evidence for $γγ\toπ^0π^0$ production at low $π^0π^0$ invariant mass.

preprint2011arXiv

Measurement of $Γ(η\to π^+π^-γ)/Γ(η\to π^+π^-π^0)$ with KLOE experiment

We report the measurement of the ratio $Γ(η\to π^+π^-γ)/Γ(η\to π^+π^-π^0)$ analyzing a large sample of $ϕ\to ηγ$ decays recorded with the KLOE experiment at the DA$Φ$NE $e^+ e^-$ collider, corresponding to an integrated luminosity of 558 pb$^{-1}$. The $η\to π^+π^-γ$ process is supposed to proceed both via a resonant contribution, mediated by the $ρ$ meson, and a non resonant direct term, connected to the box anomaly. The presence of the direct term affects the partial width value. Our result $R_η=Γ(η\to π^+ π^- γ)/Γ(η\to π^+ π^- π^0)= 0.1838\pm 0.0005_{stat} \pm 0.0030_{syst}$ is in agreement with a recent CLEO measurement, which differs by more 3 $σ$ from the average of previous results.

preprint2010arXiv

Physics with the KLOE-2 experiment at the upgraded DA$ϕ$NE

Investigation at a $ϕ$--factory can shed light on several debated issues in particle physics. We discuss: i) recent theoretical development and experimental progress in kaon physics relevant for the Standard Model tests in the flavor sector, ii) the sensitivity we can reach in probing CPT and Quantum Mechanics from time evolution of entangled kaon states, iii) the interest for improving on the present measurements of non-leptonic and radiative decays of kaons and eta/eta$^\prime$ mesons, iv) the contribution to understand the nature of light scalar mesons, and v) the opportunity to search for narrow di-lepton resonances suggested by recent models proposing a hidden dark-matter sector. We also report on the $e^+ e^-$ physics in the continuum with the measurements of (multi)hadronic cross sections and the study of gamma gamma processes.

preprint2010arXiv

Proposal for taking data with the KLOE-2 detector at the DA$Φ$NE collider upgraded in energy

This document reviews the physics program of the KLOE-2 detector at DA$Φ$NE upgraded in energy and provides a simple solution to run the collider above the $ϕ$-peak (up to 2, possibly 2.5 GeV). It is shown how a precise measurement of the multihadronic cross section in the energy region up to 2 (possibly 2.5) GeV would have a major impact on the tests of the Standard Model through a precise determination of the anomalous magnetic moment of the muon and the effective fine-structure constant at the $M_Z$ scale. With a luminosity of about $10^{32}$cm$^{-2}$s$^{-1}$, DA$Φ$NE upgraded in energy can perform a scan in the region from 1 to 2.5 GeV in one year by collecting an integrated luminosity of 20 pb$^{-1}$ (corresponding to a few days of data taking) for single point, assuming an energy step of 25 MeV. A few years of data taking in this region would provide important tests of QCD and effective theories by $γγ$ physics with open thresholds for pseudo-scalar (like the $η'$), scalar ($f_0,f'_0$, etc...) and axial-vector ($a_1$, etc...) mesons; vector-mesons spectroscopy and baryon form factors; tests of CVC and searches for exotics. In the final part of the document a technical solution for the energy upgrade of DA$Φ$NE is proposed.

preprint2010arXiv

Search for neutral Higgs bosons decaying into four taus at LEP2

A search for the production and non-standard decay of a Higgs boson, h, into four taus through intermediate pseudoscalars, a, is conducted on 683 pb-1 of data collected by the ALEPH experiment at centre-of-mass energies from 183 to 209 GeV. No excess of events above background is observed, and exclusion limits are placed on the combined production cross section times branching ratio, ξ^2 = σ(e+e- --> Zh)/σ_{SM}(e+e- --> Zh) x B(h --> aa)x B(a --> τ^+τ^-)^2. For mh < 107 GeV/c2 and 4 < ma < 10 GeV/c2, ξ^2 > 1 is excluded at the 95% confidence level.

preprint2010arXiv

Status of the Cylindical-GEM project for the KLOE-2 Inner Tracker

The status of the R&D on the Cylindrical-GEM (CGEM) detector foreseen as Inner Tracker for KLOE-2, the upgrade of the KLOE experiment at the DAFNE phi-factory, will be presented. The R&D includes several activities: i) the construction and complete characterization of the full-size CGEM prototype, equipped with 650 microns pitch 1-D longitudinal strips; ii) the study of the 2-D readout with XV patterned strips and operation in magnetic field (up to 1.5T), performed with small planar prototypes in a dedicated test at the H4-SPS beam facility; iii) the characterization of the single-mask GEM technology for the realization of large-area GEM foils.

preprint2008arXiv

The CMS RPC gas gain monitoring system: an overview and preliminary results

The status of the CMS RPC Gas Gain Monitoring (GGM) system developed at the Frascati Laboratory of INFN (Istituto Nazionale di Fisica Nucleare) is reported on. The GGM system is a cosmic ray telescope based on small RPC detectors operated with the same gas mixture used by the CMS RPC system. The GGM gain and efficiency are continuously monitored on-line, thus providing a fast and accurate determination of any shift in working point conditions. The construction details and the first result of GGM commissioning are described.