Researcher profile

A. R. Marshall

A. R. Marshall contributes to research discovery and scholarly infrastructure.

ResearcherAffiliation not importedOpen to collaborate

Trust snapshot

Quick read

Trust 13 - Baseline
2works
0followers
2topics
4close collaborators

Actions

Decide how to stay connected

Follow researcher0

Research graph

See the researcher in context

Open full explorer

Inspect adjacent work, topics, institutions and collaborators without jumping out to a separate graph page.

Building this graph slice

BZPEER is loading the nearby papers, people, topics and institutions for this page.

Published work

2 published item(s)

preprint2020arXiv

I22: SAXS/WAXS beamline at Diamond Light Source -- an overview of 10 years operation

Beamline I22 at Diamond Light Source is dedicated to the study of soft matter systems from both biological and materials science. The beamline can operate in the range 3.7 keV to 22 keV for transmission SAXS and 14 keV to 20 keV for microfocus SAXS with beamsizes 240 x 60 μm$^{2}$ spot [Full width half maximum (FWHM) Horizontal (H) x Vertical (V)] at sample for the main beamline, and approximately 10 x 10 μm$^{2}$ for the dedicated microfocussing platform. There is a versatile sample platform for accommodating a range of facility, and user developed, sample environments. The high brilliance of the insertion device source on I22 allows structural investigation of materials under extreme environments (for example fluid flow at high pressures and temperatures). I22 provides reliable access to millisecond timescales, essential to understanding kinetic processes such as early folding events in proteins or structural evolution in polymers and colloids.

preprint2010arXiv

RASOR: An advanced instrument for soft x-ray reflectivity and diffraction

We report the design and construction of a novel soft x-ray diffractometer installed at Diamond Light Source. The beamline endstation RASOR is constructed for general users and designed primarily for the study of single crystal diffraction and thin film reflectivity. The instrument is comprised of a limited three circle (θ, 2θ, χ) diffractometer with an additional removable rotation (ϕ) stage. It is equipped with a liquid helium cryostat, and post-scatter polarization analysis. Motorised motions are provided for the precise positioning of the sample onto the diffractometer centre of rotation, and for positioning the centre of rotation onto the x-ray beam. The functions of the instrument have been tested at Diamond Light Source, and initial test measurements are provided, demonstrating the potential of the instrument.