Source author record

A. P. Sebedash

Explore this author’s publications, collaborators and research topics. This catalog record has not been claimed by its author.

ResearcherUnclaimed source record

Catalog footprint

Research overview

2works
1topics
2close collaborators

Published work

2 publications

preprint2019arXiv

Performance of adiabatic melting as a method to pursue the lowest possible temperature in 3^3He and 3^3He-4^4He mixture at the 4^4He crystallization pressure

We studied a novel cooling method, in which 3^3He and 4^4He are mixed at the 4^4He crystallization pressure at temperatures below 0.5 mK0.5\,\mathrm{mK}. We describe the experimental setup in detail, and present an analysis of its performance under varying isotope contents, temperatures, and operational modes. Further, we developed a computational model of the system, which was required to determine the lowest temperatures obtained, since our mechanical oscillator thermometers already became insensitive at the low end of the temperature range, extending down to (90±20) μK≈Tc(29±5)\left(90\pm20\right)\,\mathrm{μK\approx}\frac{T_{c}}{\left(29\pm5\right)} (TcT_{c} of pure 3^3He). We did not observe any indication of superfluidity of the 3^3He component in the isotope mixture. The performance of the setup was limited by the background heat leak of the order of 30 pW30\,\mathrm{pW} at low melting rates, and by the heat leak caused by the flow of 4^4He in the superleak line at high melting rates up to 500 μmol/s500\,\mathrm{μmol/s}. The optimal mixing rate between 3^3He and 4^4He, with the heat leak taken into account, was found to be about 100..150 μmol/s100..150\,\mathrm{μmol/s}. We suggest improvements to the experimental design to reduce the ultimate achievable temperature further.

preprint2019arXiv

Thermal conductivity of superfluid 3^3He-B in a tubular channel down to 0.1TcT_c at the 4^4He crystallization pressure

We studied the thermal conductivity of superfluid 3^3He in a 2.5 mm effective diameter and 0.15 m long channel connecting the two volumes of our experimental assembly. The main volume contained pure solid 4^4He, pure liquid 3^3He and saturated liquid 3^3He-4^4He mixture at varying proportions, while the separate heat-exchanger volume housed sinter and was filled by liquid 3^3He. The system was cooled externally by a copper nuclear demagnetization stage, and, as an option, internally by the adiabatic melting of solid 4^4He in the main volume. The counterflow effect of superfluid just below the transition temperature TcT_c resulted in the highest observed conductivity about five times larger than that of the normal fluid at the TcT_c. Once the hydrodynamic contribution had practically vanished below 0.5Tc0.5T_c, we first observed almost constant conductivity nearly equal to the normal fluid value at the TcT_c. Finally, below about 0.3Tc0.3T_c, the conductivity rapidly falls off towards lower temperatures.

Research graph

See the researcher in context

Open full explorer

Inspect adjacent papers, topics, institutions and collaborators without losing the researcher page.

Building this map preview

BZPEER is loading the nearby papers, people, topics and institutions for this page.