Researcher profile

A. Marcelli

A. Marcelli contributes to research discovery and scholarly infrastructure.

ResearcherAffiliation not importedOpen to collaborate

Trust snapshot

Quick read

Trust 21 - EmergingVerification L1Unclaimed author
6works
0followers
7topics
4close collaborators

Actions

Decide how to stay connected

Follow researcher0

Identity and collaboration

How to connect with this researcher

Claiming links this public author record to a researcher profile and unlocks direct collaboration workflows.

Log in to claim

Direct collaboration

Open a focused conversation when the fit is right

Claim this author entity first to unlock direct invitations.

Research graph

See the researcher in context

Open full explorer

Inspect adjacent work, topics, institutions and collaborators without jumping out to a separate graph page.

Building this graph slice

BZPEER is loading the nearby papers, people, topics and institutions for this page.

Published work

6 published item(s)

preprint2022arXiv

High Sensitivity real-time VOCs monitoring in air through FTIR Spectroscopy using a Multipass Gas Cell Setup

Human exposure to Volatile Organic Compounds (VOCs) and their presence in indoor and working environments is recognized as a serious health risk, causing impairment of varying severity. Different detecting systems able to monitor VOCs are available in the market, however they have significant limitations for both sensitivity and chemical discrimination capability. During the last years we studied systematically the use of Fourier Transform Infrared Spectroscopy (FTIR) spectroscopy as an alternative, powerful tool for quantifying VOCs in air. We calibrated the method for a set of compounds (styrene, acetone, ethanol and isopropanol) by using both laboratory and portable infrared spectrometers. The aim was to develop a new, real time and highly sensitive sensor system for VOCs monitoring. In this paper, we improve the setup performance testing the feasibility of using a multipass cell with the aim of extending the sensitivity of this sensor system down to the part per milion (ppb) level. Considering that multipass cells are now available also for portable instruments, this study opens the road for the design of new high-resolution devices for environmental monitoring.

preprint2020arXiv

Graphene Aerogels for Ultrabroadband Thermoacoustics

Sound is usually generated in a medium by an electromechanical vibrating structure. The geometrical size and inertia of the structure set the frequency cutoff in the sound-transduction mechanism and, often, different vibrating structures are necessary to cover the whole range from infrasound to ultrasound. An alternative mechanism without any physical movement of the emitter is the thermoacoustic effect, where sound is produced by Joule heating in a conductive material. Here we show that a single thermoacoustic transducer based on a graphene aerogel can emit ultrabroadband sound from infrasound (1 Hz) to ultrasound (20 MHz), with no harmonic distortion. Since conventional acoustic transducers are frequency band limited due to their transduction mechanism, ultrabroadband graphene aerogels may offer a valid alternative to conventional hi-fi loudspeakers, and infrasound and ultrasound transducers.

preprint2020arXiv

Strain induced orbital dynamics across the Metal Insulator transition in thin VO2/TiO2(001) films

VO2 is a strongly correlated material, which undergoes a reversible metal insulator transition (MIT) coupled to a structural phase transition upon heating (T= 67° C). Since its discovery the nature of the insulating state has long been debated and different solid-state mechanisms have been proposed to explain its nature: Mott-Hubbard correlation, Peierls distortion or a combination of both. Moreover, still now there is a lack of consensus on the interplay between the different degrees of freedom: charge, lattice, orbital and how they contribute to the MIT. In this manuscript we will investigate across the MIT the orbital evolution induced by a tensile strain applied to thin VO2 films. The strained films allowed to study the interplay between orbital and lattice degrees of freedom and to clarify MIT properties.

preprint2020arXiv

Tunable electronic structure and stoichiometry dependent disorder in Nanostructured VO$_x$ films

We present and discuss an original method to synthesize disordered Nanostructured (NS) VO$_x$ films with controlled stoichiometry and tunable electronic structures. In these NS films, the original lattice symmetry of the bulk vanadium oxides is broken and atoms are arranged in a highly disordered structure . The stoichiometry-dependent disorder as a function of the oxygen concentration has been characterized by in-situ X-ray Absorption Near-Edge Structure (XANES) spectroscopy identifying the spectroscopic fingerprints. Results show structural rearrangements that deviate from the octahedral symmetry with different coexisting disordered phases. The modulation of the electronic structure of the NS films based on the resulted stoichiometry and the quantum confinement in the NS particles are also discussed. We demonstrate the possibility to modulate the electronic structure of VO$_x$ NS films accessing new disordered atomic configurations with a controlled stoichiometry that provides an extraordinary opportunity to match a wide number of technological applications.

preprint2019arXiv

Tunable vortex dynamics in proximity junction arrays: a possible accurate and sensitive 2D THz detector

An array of superconducting proximity islands has been shown to be highly tunable by electric and magnetic fields. Indeed, a small change in the electric and magnetic field can tune the system from a vortex Mott insulator to a vortex metal. This transition from localized to a non-localized state can occur as soon as the density of the superconducting vortices matches the density of the pinning sites in a non defective structure. The possibility of further modulation of non-localized superconducting states via enhancement of the superconducting order parameter or modulation of the Josephson plasma frequency is discussed. Based on the non-bolometric effects associated with the occurrence of non-equilibrium phenomena in this original superconducting networks we discuss also the possible applications of this array for a conceptually new type of radiation detector.

preprint2010arXiv

Fast IR Array Detector for Transverse Beam Diagnostics at DAΦNE

At the Laboratori Nazionali di Frascati of the National Institute of Nuclear Physics (INFN) an infrared (IR) array detector with fast response time has been built and assembled in order to collect the IR image of e-/e+ sources of the DAΦNE collider. Such detector is made by 32 bilinear pixels with an individual size of 50x50 μm2 and a response time of ~1 ns. In the framework of an experiment funded by the INFN Vth Committee dedicated to beam diagnostics, the device with its electronic board has been tested and installed on the DAΦNE positron ring. A preliminary characterization of few pixels of the array and of the electronics has been carried out at the IR beamline SINBAD at DAΦNE. In particular the detection of the IR source of the e- beam has been observed using four pixels of the array acquiring signals simultaneously with a four channels scope at 1 GHz and at 10 Gsamples/s. The acquisition of four pixels allowed monitoring in real time differences in the bunch signals in the vertical direction. A preliminary analysis of data is presented and discussed. In particular we will outline the correlation between signals and displacements of the source occurring with bunch refilling during a complete shift of DAΦNE.