Researcher profile

A. Lo Giudice

A. Lo Giudice contributes to research discovery and scholarly infrastructure.

ResearcherAffiliation not importedOpen to collaborate

Trust snapshot

Quick read

Trust 21 - EmergingVerification L1Unclaimed author
14works
0followers
4topics
4close collaborators

Actions

Decide how to stay connected

Follow researcher0

Identity and collaboration

How to connect with this researcher

Claiming links this public author record to a researcher profile and unlocks direct collaboration workflows.

Log in to claim

Direct collaboration

Open a focused conversation when the fit is right

Claim this author entity first to unlock direct invitations.

Research graph

See the researcher in context

Open full explorer

Inspect adjacent work, topics, institutions and collaborators without jumping out to a separate graph page.

Building this graph slice

BZPEER is loading the nearby papers, people, topics and institutions for this page.

Published work

14 published item(s)

preprint2016arXiv

A 3-dimensional interdigitated electrode geometry for the enhancement of charge collection efficiency in diamond detectors

In this work, a single crystal CVD diamond film with a novel three-dimensional (3D) interdigitated electrode geometry has been fabricated with the Reactive Ion Etching (RIE) technique in order to increase the charge collection efficiency (CCE) with respect to that obtained by standard superficial electrodes. The geometrical arrangement of the electric field lines due to the 3D patterning of the electrodes results in a shorter travel path for the excess charge carriers, thus contributing to a more efficient charge collection mech-anism. The CCE of the device was mapped by means of the Ion Beam Induced Charge (IBIC) technique. A 1 MeV proton micro-beam was raster scanned over the active area of the diamond detector under different bias voltage conditions, enabling to probe the charge transport properties of the detector up to a depth of 8 μm below the sample surface. The experimental results, supported by the numerical simulations, show a significant improvement in the 3D-detector performance (i.e. CCE, energy resolution, extension of the active area) if compared with the results obtained by standard surface metallic electrodes.

preprint2016arXiv

Controlled variation of the refractive index in ion-damaged diamond

A fine control of the variation of the refractive index as a function of structural damage is essential in the fabrication of diamond-based optical and photonic devices. We report here about the variation of the real part of the refractive index at lambda=632.8 nm in high quality single crystal diamond damaged with 2 and 3 MeV protons at low-medium fluences (10^13 - 10^17 ions cm^-2). After implanting the samples in 125x125 um^2 areas with a raster scanning ion microbeam, the variation of optical thickness of the implanted regions was measured with laser interferometric microscopy. The results were analyzed with a model based on the specific damage profile. The technique allows the direct fabrication of optical structures in bulk diamond based on the localized variation of the refractive index, which will be explored in future works.

preprint2016arXiv

Direct fabrication and IV characterization of sub-surface conductive channels in diamond with MeV ion implantation

In the present work we report about the investigation of the conduction mechanism of sp2 carbon micro-channels buried in single crystal diamond. The structures are fabricated with a novel technique which employs a MeV focused ion-beam to damage diamond in conjunction with variable thickness masks. This process changes significantly the structural proprieties of the target material, because the ion nuclear energy loss induces carbon conversion from sp3 to sp2 state mainly at the end of range of the ions (few micrometers). Furthermore, placing a mask with increasing thickness on the sample it is possible to modulate the channels depth at their endpoints, allowing their electrical connection with the surface. A single-crystal HPHT diamond sample was implanted with 1.8 MeV He+ ions at room temperature, the implantation fluence was set in the range 2.1x10^16 - 6.3x10^17 ions cm^-2, determining the formation of buried micro-channels at 3 um. After deposition of metallic contacts at the channels' endpoints, the electrical characterization was performed measuring the I-V curves at variable temperatures in the 80-690 K range. The Variable Range Hopping model was used to fit the experimental data in the ohmic regime, allowing the estimation of characteristic parameters such as the density of localized states at the Fermi level. A value of 5.5x10^17 states cm-3 eV-1 was obtained, in satisfactory agreement with values previously reported in literature. The power-law dependence between current and voltage is consistent with the space charge limited mechanism at moderate electric fields.

preprint2016arXiv

Direct fabrication of three-dimensional buried conductive channels in single crystal diamond with ion microbeam induced graphitization

We report on a novel method for the fabrication of three-dimensional buried graphitic micropaths in single crystal diamond with the employment of focused MeV ions. The use of implantation masks with graded thickness at the sub-micrometer scale allows the formation of conductive channels which are embedded in the insulating matrix at controllable depths. In particular, the modulation of the channels depth at their endpoints allows the surface contacting of the channel terminations with no need of further fabrication stages. In the present work we describe the sample masking, which includes the deposition of semi spherical gold contacts on the sample surface, followed by MeV ion implantation. Because of the significant difference between the densities of pristine and amorphous or graphitized diamond, the formation of buried channels has a relevant mechanical effect on the diamond structure, causing localized surface swelling, which has been measured both with interferometric profilometry and atomic force microscopy. The electrical properties of the buried channels are then measured with a two point probe station: clear evidence is given that only the terminal points of the channels are electrically connected with the surface, while the rest of the channels extends below the surface. IV measurements are employed also to qualitatively investigate the electrical properties of the channels as a function of implantation fluence and annealing.

preprint2016arXiv

Finite element analysis of ion-implanted diamond surface swelling

We present experimental results and numerical Finite Element analysis to describe surface swelling due to the creation of buried graphite-like inclusions in diamond substrates subjected to MeV ion implantation. Numerical predictions are compared to experimental data for MeV proton and helium implantations, performed with scanning ion microbeams. Swelling values are measured with white light interferometric profilometry in both cases. Simulations are based on a model which accounts for the through-the-thickness variation of mechanical parameters in the material, as a function of ion type, fluence and energy. Surface deformation profiles and internal stress distributions are analyzed and numerical results are seen to adequately fit experimental data. Results allow us to draw conclusions on structural damage mechanisms in diamond for different MeV ion implantations.

preprint2016arXiv

Formation of buried conductive micro-channels in single crystal diamond with MeV C and He implantation

As demonstrated in previous works, implantation with a MeV ion microbeam through masks with graded thickness allows the formation of conductive micro-channels in diamond which are embedded in the insulating matrix at controllable depths [P. Olivero et al., Diamond Relat. Mater. 18 (5-8), 870-876 (2009)]. In the present work we report about the systematic electrical characterization of such micro-channels as a function of several implantation conditions, namely: ion species and energy, implantation fluence. The current-voltage (IV) characteristics of the buried channels were measured at room temperature with a two point probe station. Significant parameters such as the sheet resistance and the characteristic exponent (alpha) of the IV power-law trend were expressed as a function of damage density, with satisfactory compatibility between the results obtained in different implantation conditions.

preprint2016arXiv

IBIC analysis of CdTe/CdS solar cells

This paper reports on the investigation of the electronic properties of a thin film CdS/CdTe solar cell with the Ion Beam Induced Charge (IBIC) technique. The device under test is a thin film (total thickness around 10 um) multilayer heterojunction solar cell, displaying an efficiency of 14% under AM1.5 illumination conditions. The IBIC measurements were carried out using focused 3.150 MeV He ions raster scanned onto the surface of the back electrode. The charge collection efficiency (CCE) maps show inhomogeneous response of the cell to be attributed to the polycrystalline nature of the CdTe bulk material. Finally, the evolution of the IBIC signal vs. the ion fluence was studied in order to evaluate the radiation hardness of the CdS/CdTe solar cells in view of their use in solar modules for space applications.

preprint2016arXiv

IBIC characterization of an ion-beam-micromachined multi-electrode diamond detector

Deep Ion Beam Lithography (DIBL) has been used for the direct writing of buried graphitic regions in monocrystalline diamond with micrometric resolution. Aiming at the development and the characterization of a fully ion-beam-micromachined solid state ionization chamber, a device with interdigitated electrodes was fabricated by using a 1.8 MeV He+ ion microbeam scanning on a homoepitaxial, grown by chemical vapour deposition (CVD). In order to evaluate the ionizing-radiation-detection performance of the device, charge collection efficiency (CCE) maps were extracted from Ion Beam Induced Charge (IBIC) measurements carried out by probing different arrangements of buried microelectrodes. The analysis of the CCE maps allowed for an exhaustive evaluation of the detector features, in particular the individuation of the different role played by electrons and holes in the formation of the induced charge pulses. Finally, a comparison of the performances of the detector with buried graphitic electrodes with those relevant to conventional metallic surface electrodes evidenced the formation of a dead layer overlying the buried electrodes as a result of the fabrication process.

preprint2016arXiv

Lateral IBIC characterization of single crystal synthetic diamond detectors

In order to evaluate the charge collection efficiency (CCE) profile of single-crystal diamond devices based on a p type/intrinsic/metal configuration, a lateral Ion Beam Induced Charge (IBIC) analysis was performed over their cleaved cross sections using a 2 MeV proton microbeam. CCE profiles in the depth direction were extracted from the cross-sectional maps at variable bias voltage. IBIC spectra relevant to the depletion region extending beneath the frontal Schottky electrode show a 100% CCE, with a spectral resolution of about 1.5%. The dependence of the width of the high efficiency region from applied bias voltage allows the constant residual doping concentration of the active region to be evaluated. The region where the electric field is absent shows an exponentially decreasing CCE profile, from which it is possible to estimate the diffusion length of the minority carriers by means of a drift-diffusion model.

preprint2016arXiv

Luminescence centers in proton irradiated single crystal CVD diamond

Diamond displays a large variety of luminescence centers which define its optical properties and can be either created or modified by irradiation. The main purpose of the present work is to study the radiation hardness of several of such centers in homoepitaxial single crystal CVD diamond by following the evolution of photoluminescence and ionoluminescence upon 2 MeV proton irradiation. Luminescence decays were observed with values of the fluence at half of the starting luminescence (F1/2) of the order of 1014 cm-2. The 3H center displayed a non monotonic behavior, with a growing behavior and a subsequent decay with a rather high F1/2 value (in the order of few 1016 cm-2), maintaining at the highest fluences an intensity significantly higher than the blue A-band. A simple model based on a double-exponential trend was defined to fit with satisfactory accuracy the evolution of the 3H center. Several PL centers (namely: 3H, TR12, 491 nm, 494 nm) exhibited clear correlations and anti-correlations in their fluence dependences, which were considered in the attempt to acquire some insight into their possible alternative attributions.

preprint2016arXiv

Monte Carlo analysis of a lateral IBIC experiment on a 4H-SiC Schottky diode

The transport properties of a 4H-SiC Schottky diode have been investigated by the Ion Beam Induced Charge (IBIC) technique in lateral geometry through the analysis of the charge collection efficiency (CCE) profile at a fixed applied reverse bias voltage. The cross section of the sample orthogonal to the electrodes was irradiated by a rarefied 4 MeV proton microbeam and the charge pulses have been recorded as function of incident proton position with a spatial resolution of 2 um. The CCE profile shows a broad plateau with CCE values close to 100% occurring at the depletion layer, whereas in the neutral region, the exponentially decreasing profile indicates the dominant role played by the diffusion transport mechanism. Mapping of charge pulses was accomplished by a novel computational approach, which consists in mapping the Gunn's weighting potential by solving the electrostatic problem by finite element method and hence evaluating the induced charge at the sensing electrode by a Monte Carlo method. The combination of these two computational methods enabled an exhaustive interpretation of the experimental profiles and allowed an accurate evaluation both of the electrical characteristics of the active region (e.g. electric field profiles) and of basic transport parameters (i. e. diffusion length and minority carrier lifetime).

preprint2016arXiv

Multitechnique characterization of lapis lazuli for provenance study

Lapis Lazuli is one of the oldest precious stone, being used for glyptic as early as 7000 years ago: jewels, amulets, seals and inlays are examples of objects produced using this material. Only few sources of Lapis Lazuli exist in the world due to the low probability of geological conditions in which it can form, so that the possibility to associate the raw material to man-made objects helps to reconstruct trade routes. Since art objects produced using Lapis Lazuli are valuable, only non-destructive investigations can be carried out to identify the provenance of the raw materials. Ionoluminescence (IL) is a good candidate for this task. Similarly to cathodoluminescence (CL), IL consists in the collection of luminescence spectra induced by MeV ion (usually protons) irradiation. The main advantage of IL consists in the possibility of working in air while measuring simultaneously the composition of major and trace element by means of complementary Ion Beam Analysis techniques like PIXE or PIGE (Particle Induce X-ray or Gamma-ray Emission). In the present work a systematic study of the luminescence properties of Lapis Lazuli under charged particles irradiation is reported. In a first phase a multi-technique approach was adopted (CL, SEM with microanalysis, micro-Raman) to characterise luminescent minerals. This characterisation was propaedeutic for IL/PIXE/PIGE measurements carried out on significant areas selected on the basis of results obtained previously. Criteria to identify provenance of Lapis Lazuli from four of the main sources (Afghanistan, Pamir Mountains in Tajikistan, Chile and Siberia) were proposed.

preprint2016arXiv

Semiconductor characterization by scanning ion beam induced charge (IBIC) microscopy

The acronym IBIC (Ion Beam Induced Charge) was coined in early 1990's to indicate a scanning microscopy technique which uses MeV ion beams as probes to image the basic electronic properties of semiconductor materials and devices. Since then, IBIC has become a widespread analytical technique to characterize materials for electronics or for radiation detection, as testified by more than 200 papers published so far in peer-reviewed journals. Its success stems from the valuable information IBIC can provide on charge transport phenomena occurring in finished devices, not easily obtainable by other analytical techniques. However, IBIC analysis requires a robust theoretical background to correctly interpret experimental data. In order to illustrate the importance of using a rigorous mathematical formalism, we present in this paper a benchmark IBIC experiment aimed to test the validity of the interpretative model based on the Gunn's theorem and to provide an example of the analytical capability of IBIC to characterize semiconductor devices.

preprint2015arXiv

Reduction of the Semistability Condition for Tensors

In this article we study a special class of vector bundles, called tensors. A tensor consists of a vector bundle $E$ over a smooth irreducible projective variety and a morphism of vector bundles $φ$. As for classical vector bundles, there exists a notion of stability for these objects given in terms of filtrations of the vector bundle $E$. The aim of the present paper is to prove that if a destabilizing filtration is "too" long then there exists a shorter subfiltration which destabilizes as well. Moreover, we describe some related combinatorial problems, which arise from the description of a tensor $(E,φ)$ or, more precisely, a filtration of $E$ as a $a$-dimensional matrix. Eventually, as example we study semistable tensors on the projective line.