Source author record

A. J. Manninen

Explore this author’s publications, collaborators and research topics. This catalog record has not been claimed by its author.

ResearcherUnclaimed source record

Catalog footprint

Research overview

4works
5topics
4close collaborators

Published work

4 publications

preprint2021arXiv

Coulomb Blockade Thermometry on a Wide Temperature Range

The Coulomb Blockade Thermometer (CBT) is a primary thermometer for cryogenic temperatures, with demonstrated operation from below 1 mK up to 60 K. Its performance as a primary thermometer has been verified at temperatures from 20 mK to 200 mK at uncertainty level below 1 % (k = 2). In a new project, our aim is to extend the metrologically verified temperature range of the primary CBT up to 25 K. We also demonstrate close-to-ideal operation of a CBT with only two tunnel junctions when the device is embedded in a low-impedance environment.

preprint2016arXiv

Mini array of quantum Hall devices based on epitaxial graphene

Series connection of four quantum Hall effect (QHE) devices based on epitaxial graphene films was studied for realization of a quantum resistance standard with an up-scaled value. The tested devices showed quantum Hall plateaux RH,2 at filling factor i = 2 starting from relatively low magnetic field (between 4 T and 5 T) when temperature was 1.5 K. Precision measurements of quantized Hall resistance of four QHE devices connected by triple series connections and external bonding wires were done at B = 7 T and T = 1.5 K using a commercial precision resistance bridge with 50 microA current through the QHE device. The results showed that the deviation of the quantized Hall resistance of the series connection of four graphene-based QHE devices from the expected value of 4*RH,2 = 2h/e^2 was smaller than the relative standard uncertainty of the measurement (< 1*10^-7) limited by the used resistance bridge.

preprint2016arXiv

Reducing current noise in cryogenic experiments by vacuum-insulated cables

We measure the current noise of several cryogenic cables in a pulse tube based dilution refrigerator at frequencies between about 1~mHz and 50~kHz. We show that vibration-induced noise can be efficiently suppressed by using vacuum-insulated cables between room temperature and the 2nd pulse tube stage. A noise peak below 4 fA at the 1.4~Hz operation frequency of the pulse tube, and a white noise density of 0.44 fA/\sqrt{Hz} in the millihertz range are obtained.

preprint2011arXiv

Long hold times in a two-junction electron trap

The hold time ττ of a single-electron trap is shown to increase significantly due to suppression of environmentally assisted tunneling events. Using two rf-tight radiation shields instead of a single one, we demonstrate increase of ττ by a factor exceeding 10310^3, up to about 10 hours, for a trap with only two superconductor (S) -- normal-metal (N) tunnel junctions and an on-chip resistor RR (R-SNS structure). In the normal state, the improved shielding made it possible to observe τ∼τ\sim 100 s, which is in reasonable agreement with the quantum-leakage-limited level expected for the two-electron cotunneling process.

Research graph

See the researcher in context

Open full explorer

Inspect adjacent papers, topics, institutions and collaborators without losing the researcher page.

Building this map preview

BZPEER is loading the nearby papers, people, topics and institutions for this page.